Search:

Type: Posts; User: El Presidente

Search: Search took 0.01 seconds.

  1. Replies
    161
    Views
    31,932

    Ethernet cable and computer running that...

    Ethernet cable and computer running that software. LG gateway is nice that you can commission with the LCD/buttons on the unit and built in web server.

    Pres
  2. Replies
    161
    Views
    31,932

    Latest version 6.34. Enjoy!! ...

    Latest version 6.34. Enjoy!!

    http://goo.gl/3uVF05

    Pres
  3. Try port 80. Pres

    Try port 80.

    Pres
  4. Replies
    9
    Views
    498

    Same way. Monitor space temp and override units...

    Same way. Monitor space temp and override units on when setback setpoints are reached. Back off after a set differential.
  5. Replies
    9
    Views
    498

    If it uses Java then it is the old gateway. Here...

    If it uses Java then it is the old gateway. Here is the IOM:

    https://www.dropbox.com/s/fr2gccnt2jqvd4f/MFL37115823_LG%20BACnet%20Old.pdf

    Are you sure the IDUs have been discovered by the...
  6. Replies
    161
    Views
    31,932

    Ok let's see if this works. This version is three...

    Ok let's see if this works. This version is three years old so not sure if it is even current anymore. If anyone has a more current version, send it to my email and I'll setup a new link.
    ...
  7. Replies
    161
    Views
    31,932

    August posters, check your mail. Anyone else, let...

    August posters, check your mail. Anyone else, let me know.

    Pres
  8. Replies
    161
    Views
    31,932

    Version I have is 6.201. Not sure if that is even...

    Version I have is 6.201. Not sure if that is even current anymore. Haven't used it since 2011. Who wants it?!

    Pres
  9. Thread: LG V-net

    by El Presidente
    Replies
    20
    Views
    1,795

    You're welcome! Let me know if you need anything...

    You're welcome! Let me know if you need anything else.

    Pres
  10. Thread: LG V-net

    by El Presidente
    Replies
    20
    Views
    1,795

    They work. I would take the BACnet over Lon. More...

    They work. I would take the BACnet over Lon. More functionality, more capacity, and less issues. They are both monitoring and control. You can see the points lists here:
    ...
  11. Thread: LG V-net

    by El Presidente
    Replies
    20
    Views
    1,795

    What do you want to know?

    What do you want to know?
  12. Replies
    6
    Views
    672

    You should see just a bunch of points. The number...

    You should see just a bunch of points. The number after the object name corresponds with the address in the stat. For example StartStopCommand_000 corresponds with group address 1-00. 001 is 1-01...
  13. Replies
    11
    Views
    3,385

    What gateway firmware version? If it is 1.x you...

    What gateway firmware version? If it is 1.x you just have to have the equipment connected to see the points. If it is 2.x you must go in through the webserver and perform a discovery within the...
  14. Thread: Can2Go

    by El Presidente
    Replies
    37
    Views
    7,550

    Graphical programming is available. Pres

    Graphical programming is available.

    Pres
  15. For Daikin you have to limit the writes for...

    For Daikin you have to limit the writes for changes of value. If you write On when the unit is already on every two seconds it is fine as the gateway will not actively write to the indoor unit EEPROM...
  16. BACnet - Excellent, this got all my points...

    BACnet - Excellent, this got all my points working except for MSI, MSO, MSV. Thanks!

    Xarralu - SCL Elements confirmed Multi-states will not be available until November Firmware update.

    Pres
  17. CAN2GO UN2 - BACnet readProperty Request

    Hi all,

    I'm trying to use this controller to run simulations and trend points on my VRF system through a BACnet gateway.

    Script syntax for the request is (device instance, object type and...
  18. Tridium --> LG Lon Gateway SNVT Type Size Mismatch

    I'm trying to help out a guy integrating Tridium and LG and he says for SNVT nvoUnitStatus, his system reports “Type Size Mismatch (13bytes). LonMark says this data type (hvac_status) should be 12...
  19. Replies
    11
    Views
    3,385

    Ok, thanks anyway. Pres

    Ok, thanks anyway.

    Pres
  20. Replies
    11
    Views
    3,385

    Type Size Mismatch

    hvaccontrolsguy,

    I'm trying to help out a guy integrating Tridium and LG and he says for SNVT nvoUnitStatus, his system reports “Type Size Mismatch (13bytes). LonMark says this data type...
  21. Replies
    11
    Views
    3,385

    What was the problem and how did you solve it? ...

    What was the problem and how did you solve it?

    Pres
  22. Replies
    13
    Views
    2,892

    Have each of the indoor units been assigned a...

    Have each of the indoor units been assigned a group address? If not, do that and then cycle power on the gateway.

    Pres
  23. Replies
    161
    Views
    31,932

    C, check your mail. threefiddy, my e-mail...

    C, check your mail.

    threefiddy, my e-mail bounced back. Not sure what the problem is.

    Pres
  24. Replies
    161
    Views
    31,932

    C, add an email to your profile. Pres

    C, add an email to your profile.

    Pres
  25. Replies
    161
    Views
    31,932

    threefiddy, check your mail. Pres

    threefiddy, check your mail.

    Pres
  26. Replies
    161
    Views
    31,932

    Ok, what's the IP address of the Jace? It will...

    Ok, what's the IP address of the Jace? It will have to be 192.168.0.X if the gateway is left at default IP of 192.168.0.1 without enabling the gateway as a foreign device.

    If it is on a different...
  27. Replies
    161
    Views
    31,932

    De nada and you're welcome.

    De nada and you're welcome.
  28. Replies
    161
    Views
    31,932

    amigo, check your mail. Pres

    amigo, check your mail.

    Pres
  29. Replies
    161
    Views
    31,932

    What IPs for the jace and the gateway? I'll send...

    What IPs for the jace and the gateway? I'll send you the setup tool.

    Pres
  30. Replies
    161
    Views
    31,932

    Stan, Can you ping the gateway but not...

    Stan,

    Can you ping the gateway but not discover points? Are you on a different subnet than the gateway? If so the gateway might have to be setup as a foreign device.

    Pres
  31. Ok, thanks. Pres

    Ok, thanks.

    Pres
  32. Replies
    3
    Views
    2,389

    You're welcome. Pres

    You're welcome.

    Pres
  33. Replies
    3
    Views
    2,389

    That is correct. The P1-P2 (remote controller)...

    That is correct. The P1-P2 (remote controller) communications bus can handle two remote controllers max, a main and a sub. The KRP4A acts like the sub.

    Pres
  34. Reliable Controls Autodiscovery Pulls in MI from Daikin GW as Open/Closed

    Reliable Controls communicating BACnet IP to a Daikin gateway. Mode status point should have a Present Value of 1, 2, or 3 for Cooling, Heating, or Fan respectively. The point is pulled in as...
  35. Replies
    7
    Views
    2,294

    I believe event notification has to be enabled...

    I believe event notification has to be enabled with the setup tool. Ill double check when I get back from vacation.
  36. Replies
    48
    Views
    20,798

    That depends on your expectations. The ASHRAE HQ...

    That depends on your expectations. The ASHRAE HQ Renovation done recently was ALC with WebCTRL and turned out pretty good.

    How about you describe what issues you are having with the Mitsubishi...
  37. Replies
    48
    Views
    20,798

    The Daikin VRV does! :D

    The Daikin VRV does! :D
  38. Replies
    161
    Views
    31,932

    You're welcome.

    You're welcome.
  39. Replies
    161
    Views
    31,932

    There is no point configuration in the gateway....

    There is no point configuration in the gateway. The excel file is for generating a points list including object IDs and instance numbers. This is typically useful for integrators who cannot...