Search:

Type: Posts; User: gsxrsquid

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. X2

    X2
  2. Replies
    67
    Views
    3,394

    Yep, that's why we use this site. What we do in...

    Yep, that's why we use this site. What we do in the south might not be so good in the north.
  3. Replies
    67
    Views
    3,394

    I kill red for same reason. If it doesn't work at...

    I kill red for same reason. If it doesn't work at all they call for help. If you have a pan full of water in the winter you REALLY need a tech.
  4. Replies
    22
    Views
    1,331

    I have used some of the heat absorbing gels and...

    I have used some of the heat absorbing gels and they work pretty good. IF I don;t have to worry about drips i prefer a wet rag though.
  5. Replies
    11
    Views
    1,316

    funny thing, Right now I have the same model at...

    funny thing, Right now I have the same model at another facility doing this same thing. The top bearing IS bad on this one.
    Since I first posted this a couple years ago I have had to repair at...
  6. follett has a nice overhaul kit for their...

    follett has a nice overhaul kit for their machines too. You can get the evap, auger, bearings, evap drain pan and hardware even a new water supply tube for about $1500 for the L400 and less for the...
  7. Replies
    1
    Views
    353

    Follett LC 12 part needed

    I can find the installation/parts manual on the follett site but cannot find the seperate parts break down. I need either the detailed parts bulletin or the part number for the main drain that runs...
  8. Does Follett maker a quiet ice maker/dispenser?

    We have a patient area in the hospital that gets a lot of traffic becasuse of the ice machine. It is a countertop LC12 follett machine. The room is small and noise is a big factor.
    Does anyone...
  9. Replies
    2
    Views
    387

    Thanks!

    Thanks!
  10. Install the clock and walk away from the cooler. ...

    Install the clock and walk away from the cooler. :)
  11. Replies
    24
    Views
    1,728

    what they said. Sometime the users like to...

    what they said. Sometime the users like to prop the doors open because it is so cold in there (go figure) In humid areas you can frost up quick that way. Recently I have had a rash of defrost...
  12. Replies
    2
    Views
    387

    hoshi DCM-240BAF

    Does anyone have the parts list for this machine? I went to the Hoshi site and kept getting a message that there is no such machine. I was able to get the service manual but not the parts...
  13. Replies
    20
    Views
    2,870

    it is mud or iron deposits?

    it is mud or iron deposits?
  14. Replies
    15
    Views
    2,658

    aww that hoshi is almost clean. you don;t even...

    aww that hoshi is almost clean. you don;t even have any frogs living in it. :grin2:
  15. Replies
    2
    Views
    462

    Follett 25CT 400A icemaker question

    I have worked on smaller Folletts before but this is the first time I worked on this model. 18 months old and never cleaned. Mostly iron and calcium deposits. I get everything shiny and clean and...
  16. Replies
    8
    Views
    681

    Yep it was low on charge all right. Both cap...

    Yep it was low on charge all right. Both cap tubes from the TXV had been rubbing together near the sensing bulb and the bult lost it's charge and then the wear caused the machine charge to slowly...
  17. Replies
    8
    Views
    681

    SH was over 50 and SC was about 3

    SH was over 50 and SC was about 3
  18. Replies
    8
    Views
    681

    whoever installed it left the cap off the liquid...

    whoever installed it left the cap off the liquid line service port so I am hoping that is where the gas went.
  19. Replies
    8
    Views
    681

    thanks! I found that out. NOTHING on the site!

    thanks! I found that out. NOTHING on the site!
  20. Replies
    19
    Views
    2,685

    until you get a breath of it.

    until you get a breath of it.
  21. Replies
    14
    Views
    3,225

    I bought a hydraswage years ago and it has paid...

    I bought a hydraswage years ago and it has paid for itself time and again. with that and a ratchet tubing bender I replaced a few reversing valves with fewer joints and looked better too. I want...
  22. Replies
    5
    Views
    2,109

    I have one just like it in the house I bought in...

    I have one just like it in the house I bought in SE Mo. must be a state thing. :)
  23. Replies
    56
    Views
    11,528

    that's no lie. I had one ike that. person...

    that's no lie. I had one ike that. person worked at the animal shelter. when they were supposed to put down a dog or cat they brought them home. 3 bed room shouse all beds rooms full of animals...
  24. Replies
    14
    Views
    1,352

    why would you even put guages on a package unit...

    why would you even put guages on a package unit unless you thought something was wrong and had exhausted all the other possibilities?
  25. Replies
    19
    Views
    2,685

    Yeah, they said the same thing when R22 came in...

    Yeah, they said the same thing when R22 came in and started replacing R12. I don't know what is available commercially but the new big refrigerant should be CO2.
  26. Replies
    8
    Views
    681

    Bryant rooftop unit 558JP06G000A2A0AAA

    The bryant web site has no info. Init not cooling well and freezing top and bottom of evap.

    This is an R410a unit with a speed controler that controls the compressor and the condenser fan.
    OAT...
  27. Replies
    19
    Views
    2,685

    In what way? If it is an R-22 system that needs...

    In what way? If it is an R-22 system that needs charging I use R22. If the system needs replacing then I go to a 410 system, assuming HVAC.
  28. Replies
    11
    Views
    1,060

    he signed that because he feels like he will need...

    he signed that because he feels like he will need it a lot longer than 10 years.
  29. Replies
    44
    Views
    2,323

    I limit my mags to 30 rounds because the larger...

    I limit my mags to 30 rounds because the larger capacities are more likely to jam. (Just my experience with mini-14)
    I could care less about machine gun rate of fire because outside of combat they...
  30. The problem is the mental heal industry is run by...

    The problem is the mental heal industry is run by liberals who will do anything to avoid depriving someone of their rights. "It is counter productive to their recovery".
    I personally know of a...
  31. Replies
    3,469
    Views
    151,634

    If you don't like guns, don't own one. that...

    If you don't like guns, don't own one. that simple
  32. Replies
    1
    Views
    537

    Need York K2EU wiring diagram

    If anyone can tell me where to find one I will be grateful.
  33. Replies
    13
    Views
    1,528

    In Panama City Fl. I worked for a company that...

    In Panama City Fl. I worked for a company that did all the service and repairs for Trane at their factory. A roof full of voyager heat pumps. We needed parts so we went down and talked to them. ...
  34. My experience is 98% of ice machine problems are...

    My experience is 98% of ice machine problems are water with a few electrical and very few refrigerant. Not to say it doesn't happen. Big problem with hoshis is the little pieces of plastic...
  35. Replies
    40
    Views
    5,702

    :gah:

    :gah:
  36. Replies
    1
    Views
    536

    hoshi DCM270BAH wiring question

    I pulled out the gear motor/evaporator assembly to clean and rebuild it. The wiring diagram was hard to read so I thought I would be clever. I cut the wires at the connectors leave short stubs of...
  37. Replies
    8
    Views
    1,068

    I gave it 2 ounces and it is cooling fine now. ...

    I gave it 2 ounces and it is cooling fine now. Whew. on to the next project.
  38. Replies
    8
    Views
    1,068

    Well they couldn;t provide me with a part after...

    Well they couldn;t provide me with a part after all. I pulled the cap tube and measured it and got the ID with a cap tube gauge. It has been running a couple hours now and the best it will pull...
  39. Replies
    8
    Views
    1,068

    Thanks. the phone number got me the answers. I...

    Thanks. the phone number got me the answers. I brought it in the shop. Cap tube is restricted. They gave me the part number so I can order a new one and sent me a copy of the documentation too....
  40. Replies
    13
    Views
    2,655

    :cheers: amen to that!

    :cheers:

    amen to that!
  41. I've seen it. referred to it in my post...

    I've seen it. referred to it in my post actually. how is is he going to charge his system if he doesn't have a condenser full of refrigerant, or if he has a 410 system with POE oil. pulling a...
  42. Replies
    8
    Views
    1,068

    The unit isn't bad, it was the wiring diagram...

    The unit isn't bad, it was the wiring diagram that was crappy. A cheesy photocopy. The model number on the diagram did not match the number on the label in the case. The unit is a decent unit. ...
  43. What are the poor evacuation practices it...

    What are the poor evacuation practices it encourages, and what are the good practices that should be encouraged?

    I saw another post where the tech uses 2 hoses from high and low side directly to...
  44. Replies
    15
    Views
    5,317

    so even the new Sman3 has problems with the...

    so even the new Sman3 has problems with the valves and you need to get them upgraded?
  45. Replies
    8
    Views
    1,068

    and hope the cap tube isn't all waxed up

    and hope the cap tube isn't all waxed up
  46. Replies
    13
    Views
    2,816

    I had a small one pop. just swelled the bottom...

    I had a small one pop. just swelled the bottom and lifted the top off. I bet that one made a nice bang!
  47. Replies
    8
    Views
    1,068

    Lab refrigerator: Thermo Electron?!?!?

    Our lab has a sliding glass door reefer in it for keeping chemicals cool. The Name tag says :Thermo Electron Corporation. Model: SLR 4304A14
    19 ox of 134a

    It has a crappy photocopy wiring...
  48. Replies
    37
    Views
    4,760

    was that picture from southern california? I...

    was that picture from southern california? I had a buddy years ago in property management who had taken over a building and found that on the roof. Looks exactly like that rig.
  49. Replies
    14
    Views
    3,248

    I've had lizards inside units get across...

    I've had lizards inside units get across contactors and capacitors. never good for the lizard.
    The freakiest thing is contactors that draw ants by the hundreds and they keep burning up on the...
  50. Replies
    24
    Views
    4,118

    I really hate when they mount the disconnect on...

    I really hate when they mount the disconnect on the service panel so have to remove it to get in. at least that one had flex. I've seen them hard piped that way..... :/
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event