Search:

Type: Posts; User: Dann Prentiss

Search: Search took 0.00 seconds.

  1. Replies
    47
    Views
    3,027

    Yes. Every body has given me some great input....

    Yes. Every body has given me some great input. Thanks Tech83. Thanks everybody
  2. Replies
    47
    Views
    3,027

    The indoor coil is new and the txv is new

    The indoor coil is new and the txv is new
  3. Replies
    47
    Views
    3,027

    Yes It is

    Yes It is
  4. Replies
    47
    Views
    3,027

    Yes Valves are open

    Yes Valves are open
  5. Replies
    47
    Views
    3,027

    The only thing I have not checked and I feel like...

    The only thing I have not checked and I feel like an ******* now was if it did have a screen. I have scheduled to go back to the job Wednesday with new txv valve and will definitely check to see if...
  6. Replies
    47
    Views
    3,027

    Yes I understand that completely.

    Yes I understand that completely.
  7. Replies
    47
    Views
    3,027

    Yes The system is defiantly under charged.

    Yes The system is defiantly under charged.
  8. Replies
    47
    Views
    3,027

    I can not get a super heat because I cant get...

    I can not get a super heat because I cant get system fully charged to take one
  9. Replies
    47
    Views
    3,027

    No Txv only

    No Txv only
  10. Replies
    47
    Views
    3,027

    No can't get a full sight glass. High side goes...

    No can't get a full sight glass. High side goes to 250 and it says the pressure in system should not exceed 300. Filter dry seam very cool. But compressor heats up quit a bit. To hot to touch.
  11. Replies
    47
    Views
    3,027

    Yes I do Thanks

    Yes I do Thanks
  12. Replies
    47
    Views
    3,027

    Thanks guys. Never had an issue like this before....

    Thanks guys. Never had an issue like this before. Never do favors for people
  13. Replies
    47
    Views
    3,027

    Thanks man. Will the compressor re set it self?

    Thanks man. Will the compressor re set it self?
  14. Replies
    47
    Views
    3,027

    Oh ya What is id wager?

    Oh ya What is id wager?
  15. Replies
    47
    Views
    3,027

    I have pumped system down several time. Pumped...

    I have pumped system down several time. Pumped nitrogen through system. Should I remove filter dryer? Will the compressor reset it self do you know?
  16. Replies
    47
    Views
    3,027

    A/C evaporator coil. Sorry

    A/C evaporator coil. Sorry
  17. Replies
    47
    Views
    3,027

    It is a hydro air handler coil Advanced...

    It is a hydro air handler coil Advanced Distributor Products (ADP)
  18. Replies
    47
    Views
    3,027

    Can sombody help???

    I have my own small company and I know I shouldn't have done this but I'm kinda stuck now. I have a carrier condensing unit Model 38TRA060330 R-22 and bought a ADP 13 seer, changed out txv vale to...
  19. Thread: New here

    by Dann Prentiss
    Replies
    6
    Views
    373

    Am I allowed to ask Questions here?

    Am I allowed to ask Questions here?
  20. Thread: New here

    by Dann Prentiss
    Replies
    6
    Views
    373

    New here

    I'm new to this site. Not sure if I am doing the right thing here
  21. Replies
    1
    Views
    581

    What Tag?

    Have a weil mclain boiler with no tags. Can I find a serial # on block? Trying to find the age of it.:anyone:
Results 1 to 21 of 21
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event