  1. climatemaster and heat controller geothermal heat pumps the same

    I have looked over the install manuals online for Heat controller and Climate master geothermal heat pumps they look the same ,my qeustion is are they the same product thanks,model #hrv048aic01art
  2. Replies
    2
    Views
    473

    Update on Geothermal heat pump

    Hi guys first i want to say thanks to Geodude and the others for there help with my lake loop geothermal heat pump, Heat Controller Brand {RE compressor head freezing old thread } .Well i ordered a...
  3. Replies
    17
    Views
    2,254

    Thanks for all the advice so far ´ do app it and...

    Thanks for all the advice so far ´ do app it and i do have yr round power i run a 25kW el in winter thanks
  4. Replies
    17
    Views
    2,254

    Hi Geodude you are right on the money ,if you...

    Hi Geodude you are right on the money ,if you want to pm me i will give you my work # ,i have been doing hvac installs since 1988 ,as i said before i do not service and the co i wk for does not do...
  5. Replies
    17
    Views
    2,254

    each leg of the manifold on land is apx 370ft...

    each leg of the manifold on land is apx 370ft each ,why would the air side have a low temp thanks
  6. Replies
    17
    Views
    2,254

    Geothermal loop temps help

    i have had some advice here before on a install at my cabin in Canada .iwas having problems with comp head frosting on a brand new install,i was told to chq water temp on return and supply .Outside...
  7. Replies
    9
    Views
    686

    i will chq it tommorrow headed back to cabin then...

    i will chq it tommorrow headed back to cabin then thanks guys
  8. Replies
    9
    Views
    686

    Sorry u did not take that temp . Outlet was...

    Sorry u did not take that temp . Outlet was frosted for about 12ft.it was alot colder thab inlet thanks
  9. Replies
    9
    Views
    686

    need advice please on geothermal

    i have a newly installed geothermal unit with a lake loop apx 2000ft of 1in in 4 x 500ft slinkys and apx 600ft of 11/4 manifold with a 55ft rise to pump ,it does produce some heat but suction line on...
  10. Replies
    10
    Views
    901

    i think with my 45 ft rise estimated it might be...

    i think with my 45 ft rise estimated it might be a bit higher 55ft max hard to judge by looking at cabin from lake to est height , possible with the two up26-116 pumps iam not getting the gpm i...
  11. Replies
    10
    Views
    901

    I had pipe flown in with contractor to do loop...

    I had pipe flown in with contractor to do loop unit came in by winter road.it is a 4 ton unit 4 500ft loops of 1in 500ft of 1 1/4. Manifold with 45 ft rise to unit in cabin .recircs are 2...
  12. Replies
    10
    Views
    901

    Sorry to upset you geo my cabin is fly in hard to...

    Sorry to upset you geo my cabin is fly in hard to Find help i have worked on hundreds of acs and furnaces never done geo
  13. Replies
    10
    Views
    901

    geo heat pump questi˘n

    I have got my heat pump up and running at my cabin my return Air is 63f my supply Air is 78f after 3 hrs i noticed frost on suction line ßt comp i have suff ra Air flow i know by servicing ACs that...
  14. installing geo unit this weekend pump question

    iam going to finish hooking up my geothermal heat pump at my cabin in Canada this weekend ,all the ducting and wiring is done, lake loops filled and up to unit ,the question i have is on the pumps...
  15. Replies
    18
    Views
    1,926

    thanks i understood the wiring part how about the...

    thanks i understood the wiring part how about the pump install in series one in front of the other pumping dir into inlet of second pump or i at inlet conn and one at outlet conn of the heatpump...
  16. Replies
    18
    Views
    1,926

    i have been doing Hvac installs and service for...

    i have been doing Hvac installs and service for 25yrs and just doing this one geothermal for my own cabin in Canada , our main line is res and com installed forced air ,finding info on geothermal...
  17. Replies
    18
    Views
    1,926

    The unit i have is single stage with two up26 116...

    The unit i have is single stage with two up26 116 pumps
  18. Replies
    18
    Views
    1,926

    It is a heat controller hv48

    It is a heat controller hv48
  19. Replies
    18
    Views
    1,926

    Hi is there a way to calculate gpm without a flow...

    Hi is there a way to calculate gpm without a flow meter installed when pumps are installed to see if i have req gpm thanks again for all your help
  20. Replies
    18
    Views
    1,926

    thanks for the info that is a 240volt cast iron...

    thanks for the info that is a 240volt cast iron pump no need for a bronze body pump?
  21. Replies
    18
    Views
    1,926

    Geothermal recirc pump size

    I have a remote cabin in Canada and am installing geothermal ,i had the loop done by a contractor ,the total lenght of loop is apx 3000ft, 4x500ft of 1inch slinky loops in lake 8ft deep and apx 700...
  22. Replies
    5
    Views
    1,250

    Hi the person that helped with the loop knows the...

    Hi the person that helped with the loop knows the contractor which i have given a deposit too ! ,iam basically looking for some good advice will this work ,will a lgr pump help or is it a write off...
  23. Replies
    5
    Views
    1,250

    need advice on geo pond loop

    Hi need some quick advice on a pond loop that i installed with the help of a guy who had said he had done it before, i am getting a 4 ton geo unit installed next week ,i was to install loop and they...
Results 1 to 23 of 23