  1. What kind of train does he drive?

    What kind of train does he drive?
  2. This would probably get you in the right...

    This would probably get you in the right direction www.ke2therm.com/files/B-1-4_July_2013.pdf

    I haven't used it but it does modbus and is pretty inexpensive, the lead/lag you would probably have...
  3. Replies
    3
    Views
    286

    XL-10's go occupied when comm is lost.

    XL-10's go occupied when comm is lost.
  4. Replies
    11
    Views
    459

    Seems to me the bigger question is how did you...

    Seems to me the bigger question is how did you get Honeywell to open up the license? I hit a brick wall the one time I tried.
  5. Replies
    8
    Views
    547

    There is an enum point in kit control.

    There is an enum point in kit control.
  6. Replies
    11
    Views
    845

    Set it to auto.

    Set it to auto.
  7. Thread: Made me laugh

    by kirkH
    Replies
    7
    Views
    1,676

    Made me laugh

    http://www.captiveaire.com/CatalogContent/Fans/Sup_MPU/index.asp
  8. Replies
    3
    Views
    384

    http://www.niagara-central.com

    http://www.niagara-central.com
  9. Replies
    17
    Views
    3,355

    I've noticed the "made in the USA" controllers...

    I've noticed the "made in the USA" controllers we had to get from Honeywell for ARRA projects say assembled in Mexico. I guess the word made means different things when you can afford to hire the...
  10. Replies
    8
    Views
    682

    XL10's are configurable so you can't customize...

    XL10's are configurable so you can't customize the internal programming.
  11. Replies
    8
    Views
    682

    With something like that I would probably set the...

    With something like that I would probably set the DO as a free output and do the logic in Ax.
  12. Replies
    7
    Views
    441

    If you don't have enough straight duct up stream,...

    If you don't have enough straight duct up stream, you can have too much turbulence at the sensor and see this type of issue.
  13. Replies
    1
    Views
    300

    I think the big question is: do you really want...

    I think the big question is: do you really want to go down the Spyder hole?
  14. Replies
    21
    Views
    6,353

    There will be an integration module between the...

    There will be an integration module between the asd buss and the micro net buss for the vav's, I believe one for each 31 mn devices. It's been awhile I don't remember exactly what everything is...
  15. Thread: Homemade return

    by kirkH
    Replies
    15
    Views
    3,052

    I didn't know they made plenum rated OSB.

    I didn't know they made plenum rated OSB.
  16. Replies
    8
    Views
    951

    I just tested one of these on the bench that I...

    I just tested one of these on the bench that I condemned in the field. Works on the bench, I think maybe the little selector switch wasn't quite lined up just right, not sure. I don't get a warm...
  17. Replies
    26
    Views
    2,119

    I've had some luck over the years cleaning boards...

    I've had some luck over the years cleaning boards with distilled water and a toothbrush. All it takes is a little crust or whatnot to short across a couple traces. If it was underwater it may have...
  18. Replies
    12
    Views
    1,236

    That would be me. After looking at this thing it...

    That would be me. After looking at this thing it occurred to me that I never gave much thought into how something like this was being controlled back in the day when I was a service tech. Dusting...
  19. Replies
    12
    Views
    1,236

    It's all going to be managed by the BAS we are...

    It's all going to be managed by the BAS we are installing, just trying to nail down the best control scheme for the DX.
  20. Replies
    12
    Views
    1,236

    Thanks for the replies, it's a multizone all new...

    Thanks for the replies, it's a multizone all new VAV's, DAT will be reset based on demand we will control econo also. Hot gas is already piped also not sure it is really needed but I'm sure we will...
  21. Replies
    12
    Views
    1,236

    Thoughts on controlling a DX air handler

    We've got this old building we are retrofitting, the existing Trane air handler with 2 Carrier CU's is staying. Don't have M#'s not sure it would matter after 20 years of hackery not much is...
  22. Replies
    4
    Views
    547

    Maybe something like this would help...

    Maybe something like this would help http://workaci.com/products/arm-analog-re-scaling-module
  23. Thread: union math test

    by kirkH
    Replies
    29
    Views
    3,501

    Why was I expecting to find a joke here?

    Why was I expecting to find a joke here?
  24. Replies
    10
    Views
    1,431

    you will have oil return problems if you try to...

    you will have oil return problems if you try to run a compressor at less than full speed.
  25. Replies
    5
    Views
    675

    A DP switch wired to an indicator lamp of some...

    A DP switch wired to an indicator lamp of some sort would work.