  1. Replies
    2
    Views
    218

    Actually i was just logging in to edit post and...

    Actually i was just logging in to edit post and ask that very question how does one verify the relief valve is not seated as thats actually what im leaning towards as the pressure didnt doesnt rise...
  2. Replies
    2
    Views
    218

    Odd cope 6D loading behavior

    Have a cope 35HP 6D remaan'd by Mcquay. During the off cycle short cycles incessivley. Front seated suction service valve and verified a head is blowing by- The strange thing is when i run the...
  3. Replies
    5
    Views
    292

    Yes I easily could've missed a seperate device...

    Yes I easily could've missed a seperate device that is a 24v signal amp. Lots of controllers on the wall. Is far as mislabeling that doesn't happen does it?
  4. Replies
    5
    Views
    292

    It does not power any of them like I said it is a...

    It does not power any of them like I said it is a regular transformer that says signal amplifier never seen that
  5. Replies
    5
    Views
    292

    24vac signal amp

    Ahu room had a plan 40va 24v xfrnr marked signal amplifier . Just wondering as to what's its purpose is although I imagine it gas to do with almost 30 actuators sharing a signal just looking for any...
  6. Replies
    19
    Views
    681

    That is true. So if where in 100% hgbp and our...

    That is true. So if where in 100% hgbp and our recips are suction gas cooled we can only hope it doesn't run overheated?funny I went from flooding to overheating compressors. Ice makes a convincing...
  7. Replies
    19
    Views
    681

    Yes I'm sure there's no intention to alter the...

    Yes I'm sure there's no intention to alter the piping and it'll still be distrod directly after the TXV. The idea is more precise dat control only. The DHRE works just fine and serves its purpose-...
  8. Replies
    19
    Views
    681

    I see this in precision cooling apps- CRACS. And...

    I see this in precision cooling apps- CRACS. And in my mind they're scrolls. Comfort cooling hardly demands such precise DAT. I realize the TXV will throttle back but if we're running hot gas were...
  9. Replies
    19
    Views
    681

    But I like the old one... Ha

    But I like the old one... Ha
  10. Replies
    19
    Views
    681

    Systems already have hot gas and have been in...

    Systems already have hot gas and have been in service for almost 20 years. Some consultant recommends this fancy new hgbp for more precise dat control during DX season. My fear is too much hot gas...
  11. Replies
    19
    Views
    681

    A hot gas valve that will modulate based on DAT...

    A hot gas valve that will modulate based on DAT for more precise dat control won't to much hit gas flood evap
  12. Replies
    19
    Views
    681

    Yes two circuits 40 ton each one with hot gas

    Yes two circuits 40 ton each one with hot gas
  13. Replies
    19
    Views
    681

    Hot gas bypass and slugging

    As part of renovations a "mechanical enginerring consultant" recommends putting some sort of digital hot gas bypass to let the compressors run at next to nothing capacity. It is always fashionable to...
  14. Replies
    21
    Views
    1,070

    I totally agree that to open again for minor...

    I totally agree that to open again for minor repair and replace new dryer is pointless and waste of time. As far as the HH driers and 404 I was referring to retrofit scenerios and the fact that the...
  15. Replies
    21
    Views
    1,070

    That's another cause for discussion sporlan...

    That's another cause for discussion sporlan literature speaks of HH driers basically for removal of parafin wax as in lowtemp 404 retrofits but I hear guys talk about using them after a burnout...
  16. Replies
    21
    Views
    1,070

    If out of shear bored em I can see baking it. I...

    If out of shear bored em I can see baking it. I think I small purge while I rebuild a solenoid will keep it plenty dry- something that should be done anyways
  17. Replies
    21
    Views
    1,070

    Because I've read on this very site dudes- and...

    Because I've read on this very site dudes- and here's one I don't understand- baking an old dryer in the oven to save the $25 cost of a new dryer. That's one I don't get- I'm suggesting a more...
  18. Replies
    21
    Views
    1,070

    "Drying" a drier

    Long story short after replacing a drier the other day I realized I need to open the system for repair again briefly. Was thinking of placing a heat lamp above the dryer while it evacuates again to...
  19. Replies
    2
    Views
    255

    I could be dead wrong here but it's a data center...

    I could be dead wrong here but it's a data center and I believe it may be on ups already
  20. Replies
    2
    Views
    255

    York chiller YLAA101 takes down BACNET

    Have a York YLAA101HE46X chiller. Everytime the facility does a load transfer gen test all devices go offline. Isolated problem to the chiller which uses BACNET gateway. Have to cycle control power...
  21. Replies
    24
    Views
    1,681

    My main point was regarding hairline cracks in...

    My main point was regarding hairline cracks in commercial equipment absolutley an atmospheric vented fan temp or time on would expose a co risk- on say a a continuos fan Rtu with induced draft if the...
  22. Replies
    12
    Views
    993

    [QUOTE=VTP99;17620201] 10-15lbs at least

    10-15lbs at least
  23. Replies
    12
    Views
    993

    The line "worked well" was in reference to the...

    The line "worked well" was in reference to the retrofit procedure. I knew it was wrong hence spending my "off" time - as if there really was such a thing- dwelling on stuff. I was more less intrigued...
  24. Replies
    12
    Views
    993

    I regress I have heard of dual pressure...

    I regress I have heard of dual pressure headmasters- if I remember right U break off one of the bulb stubs
  25. Replies
    12
    Views
    993

    So wouldn't just charging to clear site glass...

    So wouldn't just charging to clear site glass with cond coil wide open have an overcharge condition in the warmer weather