  1. Replies
    42
    Views
    3,790

    I Have been in the heating and air business for...

    I Have been in the heating and air business for over 6yrs and where I am from we have other companies that are infamous for condemning furnaces that are fine.If the other contractor is putting it in...
  2. Replies
    5
    Views
    1,543

    All contractors are different,some charge...

    All contractors are different,some charge more,but if they are punctual,profesional,and you are happy with the job it will be fine.Next time you may call someone who charges less,but shows up late,or...
  3. Replies
    11
    Views
    1,517

    The smaller of the 2 is for the outdoor fan motor...

    The smaller of the 2 is for the outdoor fan motor and the larger for the compressor,if the smaller cap. is bad it may be bulged where the wires hook up.
  4. Thread: residential hvac

    by azel6
    Replies
    9
    Views
    1,148

    The compressor is off on internal overload.Take...

    The compressor is off on internal overload.Take some cold water from your garden hose and run over the compressor until it resets the overload.Than run the unit you will probably find a low charge,or...
  5. Replies
    11
    Views
    1,517

    If the motor is a single shaft sitting on...

    If the motor is a single shaft sitting on top,then a universal 1/4hp motor should work for you.Any heating and air contractor should have one.Don't forget to have them check the capacitor,this time...
  6. Replies
    11
    Views
    1,517

    Is the fan motor a single shaft or adouble...

    Is the fan motor a single shaft or adouble shafted motor,Is the fan on the top or on the side?Most of the time you could probably use a universal motor,but if the system is 18 years old you probably...
  7. I would have to say that the system is probably a...

    I would have to say that the system is probably a little overcharged,listen to what the other guys are saying and have someone come and look at it.Most of the time simple problems don't show up until...
  8. Replies
    2
    Views
    692

    If there is water coming out of the emergency...

    If there is water coming out of the emergency drain pan maybe the installer did not trap the drain and the water is not draining and overfilling the pan.Usually if the txv is installed,the txv would...
  9. Replies
    38
    Views
    2,391

    MAYBE YOU SHOULD GO OUTSIDE WHEN THE UNIT IS...

    MAYBE YOU SHOULD GO OUTSIDE WHEN THE UNIT IS RUNNING AND SEE WHAT IT IS DOING.IT SOUNDS LIKE THE COMPRESSOR IS SHUTTING OFF DURING OPERATION,MAYBE LOW ON REFRIDG. AND OVERHEATING.