Search:
Type: Posts; User: helgy
Search: Search took 0.01 seconds.
-
03-15-2013, 07:49 AM
- Replies
- 1
- Views
- 219
Larger Carrier/Bryant heat ex. replaceable in sections?
I have a M# 580DPV090180ACAA that has rusted through on the right 4 tubes. The left 3 are ok and actually look newer. This would lead me to believe that the two sections can be replaced separately....
-
03-08-2013, 01:05 PM
Thread: alk in freezer moisture refreeze on ceiling
by helgy- Replies
- 10
- Views
- 367
What I came up with is the defrost term. Switch...
What I came up with is the defrost term. Switch is working. I have 208v between 3 and X back at the clock. Still will not term defrost. Must have a bad defrost term relay in the time clock. Is this a...
-
03-08-2013, 11:11 AM
Thread: alk in freezer moisture refreeze on ceiling
by helgy- Replies
- 10
- Views
- 367
On site right now. I will try that. Thanks
On site right now. I will try that. Thanks
-
03-07-2013, 08:47 PM
Thread: alk in freezer moisture refreeze on ceiling
by helgy- Replies
- 10
- Views
- 367
Good info. Heading back to the site tomorrow. I...
Good info. Heading back to the site tomorrow. I will run it through a complete defrost cycle. Thanks
-
03-07-2013, 08:03 PM
Thread: alk in freezer moisture refreeze on ceiling
by helgy- Replies
- 10
- Views
- 367
freezer
Yes it is. Seems like excess moisture off the evap.
-
03-07-2013, 07:35 PM
Thread: alk in freezer moisture refreeze on ceiling
by helgy- Replies
- 10
- Views
- 367
alk in freezer moisture refreeze on ceiling
Working on a small walkin freezer that is about 1 1/2 yrs old. It has had the issue of moisture refreezing on the ceiling. Did have a backed up drain. That has been fixed. Otherwise freezer working...
-
12-04-2012, 07:32 AM
Thread: Copeland 9RS3-0760-TFC compressor
by helgy- Replies
- 4
- Views
- 568
Thanks guys for the help.
Thanks guys for the help.
-
11-30-2012, 03:28 PM
Thread: Copeland 9RS3-0760-TFC compressor
by helgy- Replies
- 4
- Views
- 568
Copeland 9RS3-0760-TFC compressor
Working on this compressor that has a combo pressure control with both cap tubes hooked to the compressor head. Can this be correct? Must be, its been in for 20+ years. Anyone know more about these...
-
11-09-2012, 09:39 AM
Thread: copelamatic compressor making noise
by helgy- Replies
- 9
- Views
- 935
copelamatic compressor making noise
Hey guys I'm checking out a Copeland M# ERF1-0310-TAC-218. This compressor serves a walk in cooler. It was holding temp ok and pressures were good. But the customer was complaining ab out the loud...
-
11-08-2012, 09:19 PM
Thread: commercial air handler controls layout
by helgy- Replies
- 17
- Views
- 1,151
Thanks guys for all the help. Good info.
Thanks guys for all the help. Good info.
-
11-07-2012, 09:04 PM
Thread: commercial air handler controls layout
by helgy- Replies
- 17
- Views
- 1,151
ncboston thats what I'm looking for. I tried to...
ncboston thats what I'm looking for. I tried to print it not coming out very well. Do you have a darker scan or a source on the internet I can go to. Let me know.
supertek65 if you could scan or... -
11-07-2012, 07:40 PM
Thread: commercial air handler controls layout
by helgy- Replies
- 17
- Views
- 1,151
Thanks flange I will give that a try. If anyone...
Thanks flange I will give that a try. If anyone has any other ideas I'm still open
-
11-06-2012, 09:28 PM
Thread: commercial air handler controls layout
by helgy- Replies
- 17
- Views
- 1,151
commercial air handler controls layout
I have a controls test coming up for a job position. I seem to remember a few years back a Johnson Controls layout for a commercial air handler. It showed all the controls and placement of them....
-
11-06-2012, 09:27 PM
Thread: commercial air handler control layout
by helgy- Replies
- 1
- Views
- 310
commercial air handler control layout
I have a controls test coming up for a job position. I seem to remember a few years back a Johnson Controls layout for a commercial air handler. It showed all the controls and placement of them....
-
07-16-2012, 11:07 PM
Thread: walk in freezer problem
by helgy- Replies
- 10
- Views
- 629
it pumps down with the solenoid and holds the...
it pumps down with the solenoid and holds the suction. Or are you refering pumping down using the service valves. I did not do the later of the two.
Did not get the water cooled temps. What kind... -
07-16-2012, 10:55 PM
Thread: walk in freezer problem
by helgy- Replies
- 10
- Views
- 629
refrigerant 404A Box temp 21 Ambient around...
refrigerant 404A
Box temp 21
Ambient around box 75 to 80 -
07-16-2012, 10:19 PM
Thread: walk in freezer problem
by helgy- Replies
- 10
- Views
- 629
walk in freezer problem
I'm working on a walk in freezer. Here are the stats.
suction 33 psi
head 270 psi
supheat 25 degrees - way to high
subcooling 10 degrees
sight glass is clear
this is a water cooled unit... -
06-05-2012, 10:55 PM
Thread: Trane - Robertshaw Guard Pac 3
by helgy- Replies
- 3
- Views
- 760
well made a trip back to this call today. Using...
well made a trip back to this call today. Using the two step method. I figured out two things.
1. I have a bad oil pressure switch. Have 20#'s oil pressure and it will not close.
2. the GP will... -
06-04-2012, 11:02 PM
Thread: Trane - Robertshaw Guard Pac 3
by helgy- Replies
- 3
- Views
- 760
Trane - Robertshaw Guard Pac 3
Can anyone direct me to an instruction or troubleshooting paper work for this control?
Condenser would not run. the lock out relay had 120v. going to it. Tried the reset botton, would not reset. ... -
12-16-2011, 12:09 AM
Thread: Intertherm gas fireplace
by helgy- Replies
- 0
- Views
- 2,090
Intertherm gas fireplace
Looking for Intertherms gas fireplace contact info. i have a warranty question for them.
Any help would be great..
Thanks, Helgy -
12-12-2011, 06:47 AM
Thread: Hoshizaki bin switch
by helgy- Replies
- 7
- Views
- 4,299
bin control
Ok I'll give that a try. Thanks for the help.
-
12-11-2011, 11:21 PM
Thread: Hoshizaki bin switch
by helgy- Replies
- 7
- Views
- 4,299
Hoshizaki bin switch
Never been a big fan of Hoshizaki ice machines. I'm stuck working on one anyway. The bin sensor has gone bad. Has anyone had any luck using another type of cold control or digital refrigeration stat....
-
10-17-2011, 07:28 PM
Thread: Dovre DV450S need burner
by helgy- Replies
- 3
- Views
- 665
Yep I kind of figured that. Thought I would take...
Yep I kind of figured that. Thought I would take a shot at it though. Guess I will have to go back to my former employer to get the part. Doesn't that sound like fun.. not.
-
10-16-2011, 06:50 PM
Thread: Dovre DV450S need burner
by helgy- Replies
- 3
- Views
- 665
Dovre DV450S need burner
Anyone know outside of Hearth and Home (Heat and Glow) were I can get a burner for a 450S. Hopefully online.
Thanks for the help. -
09-27-2011, 10:28 PM
Thread: REPLACEMENT OF YORK ISN CONTROLER
by helgy- Replies
- 8
- Views
- 961
REPLACEMENT OF YORK ISN CONTROLER
Is there something a little more user friendly out on the market today a person could use to replace this system with that would still intregate with the sensors and York chillers that are in place...
Results 1 to 25 of 96