  1. Replies
    41
    Views
    1,986

    It's the same as the 550 less the temp clamps. ...

    It's the same as the 550 less the temp clamps. I've had my 550 for 4 years, have had to replace the temp probes once. Have never had a regular manifold stand up as well as these and I use them on...
  2. Replies
    8
    Views
    253

    better to use a tandem set up, a regular 72,000...

    better to use a tandem set up, a regular 72,000 normally will not work as the oil sumps must be connected with a seperate line. If someone has already changed them maybe they got it wrong. It may...
  3. Replies
    16
    Views
    635

    if there is room install a swival tee with new...

    if there is room install a swival tee with new schraders in the tee's
  4. I like the idea, remember it can work both ways. ...

    I like the idea, remember it can work both ways. You can evaluate them at the same time
  5. Replies
    7
    Views
    715

    Cooper sh66

    Cooper sh66
  6. Replies
    7
    Views
    560

    replace the damper in the basement with a...

    replace the damper in the basement with a motorized damper and give them a switch
  7. Do an isolation, I have seen H10 pick up a leak...

    Do an isolation, I have seen H10 pick up a leak from clorine that utilities inject into water systems from a water fountain
  8. Replies
    3
    Views
    467

    the indoor coil is the condenser in the winter,...

    the indoor coil is the condenser in the winter, and normally it is not as large as the outdoor coil
  9. Replies
    3
    Views
    534

    check your preasure drop accross your condenser,...

    check your preasure drop accross your condenser, you may find that is where your problem is. Have seen this before and had to use a line tap on the condenser outlet to find it.
  10. Replies
    22
    Views
    1,352

    Never saw a copper spun muffler and being it...

    Never saw a copper spun muffler and being it sounds as tho it is on the outlet of the condenser coil it's probally a drier
  11. Replies
    22
    Views
    1,352

    who is the mfg. You said they sent a drier for a...

    who is the mfg. You said they sent a drier for a straight condenser. York put driers on the compressor discharge line on their heat pumps some years back.
  12. with high superheat, low head, and low suction it...

    with high superheat, low head, and low suction it sounds as tho you may still be low on refrigerant especially with a fixed metering device. Would need to know what your subcooling is along with a...
  13. Replies
    19
    Views
    1,616

    FYI when I only have one good condenser motor out...

    FYI when I only have one good condenser motor out of 2 and there is no baffel between them I cover the dead ones opening will make a difference on trying to keep the head psi down
  14. Replies
    26
    Views
    1,895

    if you have it overcharged by 2 pounds you...

    if you have it overcharged by 2 pounds you probally need to get it out or you may loose the compressor especially with a fixed orfice. Rule of thumb if you have low superheat adding refrigerant will...
  15. Thread: Temp meters.

    by SouthTex
    Replies
    15
    Views
    1,611

    I have used the Cooper Atkins SRH 77A for years,...

    I have used the Cooper Atkins SRH 77A for years, have no issues with calibration and I check it from time to time. it is great for a/c work for splits and if you need humidity readings. Also does...
  16. Replies
    24
    Views
    1,991

    Dumb question but have you tried reversing the...

    Dumb question but have you tried reversing the rotation on the compressor?
  17. Thread: Heat Pump TXV

    by SouthTex
    Replies
    20
    Views
    1,778

    With a 65 outdoor and a 74 indoor I would expect...

    With a 65 outdoor and a 74 indoor I would expect to see high preasures. Try running the unit in the heat mode and disable the outdoor fan. The outdoor txv should lower the suction preasure which...
  18. Read your incoming power and make sure the right...

    Read your incoming power and make sure the right voltage tap is being used, if it is set for 240 and you only have 208 your secondary voltage will be too low and will cause this issue see it alot
  19. ACCA-SA South Texas Trade Show January 15th

    The San Antonio Chapter of ACCA has it's Trade show coming up this Wednesday. There will be seminars for both owners/principals and techs. Ruth King will be the keynote speaker. The vender fair...
  20. Replies
    8
    Views
    707

    Run a PT check

    Run a PT check
  21. Replies
    12
    Views
    1,560

    If it's a small area realitive to the size of the...

    If it's a small area realitive to the size of the system we have used the ZoneX damper systems and seems to work fairly well. They have a modulating damper with a sensor in the supply air to help...
  22. Replies
    7
    Views
    760

    New pan if available(with no warranty on existing...

    New pan if available(with no warranty on existing coil) and give them an option for a new pcoil with warranty
  23. Replies
    13
    Views
    1,143

    Had one years ago on a GE package heat pump. ...

    Had one years ago on a GE package heat pump. Intermitten restriction, 4 companies looked at along with factory rep would not happen on a regular basis. Finally got it to act up, cut tubing and...
  24. Replies
    9
    Views
    936

    What was your voltage accross the capacitor while...

    What was your voltage accross the capacitor while it was running, you may find 370 is ok
  25. Old school we still have alot of the Lennox Zone...

    Old school we still have alot of the Lennox Zone masters in place, have some condensers with 8 ahu's connected to a 15 ton system.
    Lennox had a version for the residential market.
  26. Replies
    22
    Views
    2,202

    Save inventory and carry only the 440

    Save inventory and carry only the 440
  27. Replies
    6
    Views
    783

    Will give it a try, but out of coursity how did...

    Will give it a try, but out of coursity how did you find this as the issue?
  28. Replies
    6
    Views
    783

    Older job sites installed by others, wiring looks...

    Older job sites installed by others, wiring looks great and no issues with other 10 units at each site. I assume the tracker system is used to report and send set points to the onboard controller.
  29. Replies
    6
    Views
    783

    Reliatel controls issue

    Have a Trane Model YHC 102A4RLA2GD0B/Serial 638100715l with reliatel controls on a tracker system with a 3 wire zone sensor. Tracker showing -67 degrees space temp and the cool not operating. Check...
  30. Replies
    9
    Views
    773

    Are you using stamped faced grills? Bar type...

    Are you using stamped faced grills? Bar type grills have less of a noise issue normally, less restrictive
  31. Replies
    5
    Views
    592

    Head psi seems high check for a restriction maybe...

    Head psi seems high check for a restriction maybe some one has over charged it to get the suction up. Really need to know superheat and subcooling and temp drop accross the evap.
  32. Replies
    74
    Views
    7,995

    Agree only might want to use unions to make it...

    Agree only might want to use unions to make it easier the next time and there will be a next time to access it
  33. Replies
    9
    Views
    1,325

    Try going a little more south to San Antonio,...

    Try going a little more south to San Antonio, plenty of work and all the good firms are looking for good people. Cost of living is less and you don't have as many traffic issues to deal with. I...
  34. Replies
    16
    Views
    846

    You may also look at your grill selection, hvs...

    You may also look at your grill selection, hvs type grills seem to work better
  35. Replies
    13
    Views
    1,533

    Most pkg units have multi tap transformers 208 or...

    Most pkg units have multi tap transformers 208 or 230. Make sure its tapped for 208 with the voltage you are reading. I normally see 26 or 27 when transformer is tapped properly.
  36. The device you are looking for is called a...

    The device you are looking for is called a helper, they normally are just out of trade school and don't stay long, they just don't build them like they used to.
  37. Thread: Tricky one

    by SouthTex
    Replies
    18
    Views
    1,755

    take some temp readings on your return bends of...

    take some temp readings on your return bends of the evap, you may have a restriction and some one has overcharged it and is overfeeding on the unrestricted areas of the coil
  38. Replies
    6
    Views
    611

    forget the indoor temp if you are looking for...

    forget the indoor temp if you are looking for evap load in the heat mode, the condenser is now the evap. Have found in years past on some units we would cycle the outdoor fan in the heat mode by...
  39. Replies
    13
    Views
    1,316

    Why I like the digital gauges all the imformation...

    Why I like the digital gauges all the imformation is built in
  40. Replies
    16
    Views
    1,345

    sometimes alignment of the puller can be a...

    sometimes alignment of the puller can be a problem, on 1/2" shafts put a copper coupling on the shaft of the motor, sure makes it easier
  41. Replies
    4
    Views
    898

    If it has a multi tap transformer make sure it is...

    If it has a multi tap transformer make sure it is on the right tap. Have seen where they are taped for 230 volt and there is 208 being supplied. Will make a difference when the contactors pull in. ...
  42. Replies
    9
    Views
    761

    crankcase heater will keep the liquid refrigerant...

    crankcase heater will keep the liquid refrigerant out of the crankcase but will do nothing to keep large amounts of refrigerant from slugging that has accumulated in the coil or in the lineset. I...
  43. Replies
    6
    Views
    873

    Recently picked one up at Home Depot called the...

    Recently picked one up at Home Depot called the whistler for under a hundred. First day out found 2 dirty evap coils going thru the high limit, of furnaces paid for itself right then and there.
  44. Don't forget checking the temp drop accross the...

    Don't forget checking the temp drop accross the indoor coil, I have seen units that have the correct subcooling / superheat but still have a low temp drop.
  45. Sounds as tho there is a Lovejoy coupling. Get...

    Sounds as tho there is a Lovejoy coupling. Get shaft size and you should be able to find a replacement. The tough part is getting the old one to move, sanding and lots of wd 40. May have to pull...
  46. Thread: carrier clo

    by SouthTex
    Replies
    1
    Views
    693

    install a icm voltage monitor and set it up for...

    install a icm voltage monitor and set it up for auto rest
  47. Replies
    48
    Views
    7,429

    Keep a set of gear wrenches to 9/16" in bag along...

    Keep a set of gear wrenches to 9/16" in bag along with set of Dewalt magnetic nut setter to 1/2" for my impack driver. Very seldom have to use sockets any more. Keep an extension for the nut...
  48. Replies
    7
    Views
    2,297

    You are right it is a filter drier, had a...

    You are right it is a filter drier, had a customer that had 3 compressor failures and the company doing the work thought it was a muffler and never changed it. It was a split York heat pump figured...
  49. Replies
    28
    Views
    4,210

    You said this was a heat pump outdoor, would not...

    You said this was a heat pump outdoor, would not use a solenoid with a heat pump with out some specical consideration for the heating cycle. Is there a suction acculator installed between the...
  50. Replies
    17
    Views
    3,645

    Had similar problem, Rheem unit with 4...

    Had similar problem, Rheem unit with 4 compressors set up for 2 stages, thermostat 150 ft run. When contactors pulled in they chattered, especially if calling for both stages, low voltage dropped to...
Results 1 to 50 of 226