08-22-2012, 03:08 PM
Thread: BTU's per square feet
by 7X- Replies
- 48
- Views
- 5,772
My 2000 sq ft house has a cooling load of 1.5...
My 2000 sq ft house has a cooling load of 1.5 tons - you are not going to get a return call if you ROT a 3.5 to 4 ton price at me. Just sayin.....
I get the whole "quote over the phone" thing for... -
07-31-2012, 02:47 PM
Thread: Heat problem-6 months to fix
by 7X- Replies
- 21
- Views
- 1,097
If it is truly power vented, then the termination...
If it is truly power vented, then the termination should not make a difference but then it would also not make much sense that the problem started after re-roofing. Type B vent is also not the...
-
07-28-2012, 09:20 AM
Thread: To set back, or not to set back?
by 7X- Replies
- 24
- Views
- 1,522
Strictly speaking from the combustion heating...
Strictly speaking from the combustion heating side - I remember quite a while back there was some testing done and conclusions made. I was told years ago that you could save 1%/degree/8hrs. Set...
-
07-28-2012, 08:57 AM
Thread: Heat Exchanger sweating
by 7X- Replies
- 24
- Views
- 1,281
It is not uncommon to have pressures in the...
It is not uncommon to have pressures in the building that are negative with reference to the outside when an air handler is operating. Could be due to duct leaks or door closure issues. So it is...
-
11-06-2008, 08:18 PM
- Replies
- 17
- Views
- 3,869
Loonie and Heybob are correct. THe unit has to...
Loonie and Heybob are correct. THe unit has to be rated for mobile home use. The Carrier unit needs to be modified to handle the high static duct system. Modular and manufactured housing are...
-
01-18-2007, 06:01 PM
Thread: lawyer joke?
by 7X- Replies
- 7
- Views
- 1,011
Why can't lawyers use Viagra? Makes 'em too...
Why can't lawyers use Viagra?
Makes 'em too tall. -
10-19-2006, 01:28 PM
- Replies
- 62
- Views
- 4,284
swnoel - I agree and wish you well.
swnoel - I agree and wish you well.
-
10-19-2006, 10:09 AM
- Replies
- 62
- Views
- 4,284
Wptski posted: "A bit off topic but my sister...
Wptski posted:
"A bit off topic but my sister was getting headaches and finally figured out that they only came after doing her laundry! The furnace, water heater and dryer are all gas in that... -
03-09-2006, 07:57 PM
Thread: venting furnace through masonry chimney
by 7X- Replies
- 5
- Views
- 2,307
No, the codes didn't change. I have an AGA...
No, the codes didn't change. I have an AGA publication from (I believe) 1990 that details the changes in the furnaces and addresses changes in venting, including tables. Venting instructions were...
-
02-20-2006, 09:23 AM
- Replies
- 21
- Views
- 1,089
I think much of what has been said is valid. I...
I think much of what has been said is valid. I am just going to summarize some of it. Condensation on the windows is a function of the temp of the windows and the amount of moisture in the house. ...
-
01-26-2006, 06:12 PM
Thread: Low temperature rise -help
by 7X- Replies
- 19
- Views
- 1,607
High vent temp and low air temp rise? Is the...
High vent temp and low air temp rise? Is the inside of the heat exchanger sooted up?
-
01-26-2006, 06:00 PM
Thread: Performance check on new furnace
by 7X- Replies
- 4
- Views
- 602
A couple things to look at might be duct leakage...
A couple things to look at might be duct leakage and proper air flow. Kind of hard to tell if the insulation is proper with a blower door. IR camera would be better.
-
01-18-2006, 07:48 AM
Thread: dye test kit
by 7X- Replies
- 4
- Views
- 743
Be aware that this test has some limitations -...
Be aware that this test has some limitations - seeing past the first bend on a tubular heat exanger...etc. Also need to consider heat exchanger construction. Some heat exchangers are built with an...
-
01-17-2006, 05:44 PM
Thread: dye test kit
by 7X- Replies
- 4
- Views
- 743
http://www.visibledefects.com Out of Missouri...
http://www.visibledefects.com
Out of Missouri I think. -
01-17-2006, 06:41 AM
- Replies
- 15
- Views
- 1,423
I'm with Loonie on duct issues and air flow. ...
I'm with Loonie on duct issues and air flow. Make sure there are no leaks - particularly from the garage. The air flow thing is huge - if the furnace is cycling on the limit switch, that could...
-
01-11-2006, 08:59 AM
Thread: furnace question??
by 7X- Replies
- 164
- Views
- 8,190
Tchntch mentioned durability - that's something...
Tchntch mentioned durability - that's something that I don't think is being talked about enough in this discussion. While the properly sized furnace should run all the time at design temp, it does...
-
01-11-2006, 08:27 AM
Thread: Water heater or TMV problem?
by 7X- Replies
- 19
- Views
- 1,009
Yes, it's possible you could have had an...
Yes, it's possible you could have had an intermittent problem with the mixing valve. If it happens again, I would have it serviced.
-
01-10-2006, 04:23 PM
Thread: Water heater or TMV problem?
by 7X- Replies
- 19
- Views
- 1,009
Good thought on the dip tube. The reason I asked...
Good thought on the dip tube. The reason I asked about the instantaneous heater is because I was wondering why you have a mixing valve in the first place. Is it really necessary with your system?
-
01-10-2006, 09:39 AM
Thread: Water heater or TMV problem?
by 7X- Replies
- 19
- Views
- 1,009
Is this an instantaneous heater? If you are...
Is this an instantaneous heater? If you are somewhat mechanical, maybe you can feel the pipe going to the mixing valve from the tank. If it is always nice and hot and the water coming out of the...
-
01-10-2006, 09:19 AM
Thread: furnace question??
by 7X- Replies
- 164
- Views
- 8,190
This has been a pretty entertaining thread. ...
This has been a pretty entertaining thread.
Trane, thanks for summarizing what appears to be the latest point of contention. It is always a good idea to point out where we agree versus disagree. ... -
01-10-2006, 08:43 AM
Thread: New Construction Questions
by 7X- Replies
- 21
- Views
- 1,705
My vote is for electric backup also. I am not a...
My vote is for electric backup also. I am not a big fan of propane appliances installed below grade. The thought I had was to find out if your electric utility will give a rebate for going all...
-
01-07-2006, 09:00 AM
Thread: furnace question??
by 7X- Replies
- 164
- Views
- 8,190
Maybe Deejoe is approaching this from a job...
Maybe Deejoe is approaching this from a job security perspective. Two six minute cycles at ten degrees outside? (Doesn't seem like a very real world example - must not run at all when its fifty...
-
12-23-2005, 09:31 AM
Thread: filter at the return grille
by 7X- Replies
- 12
- Views
- 999
Here's another thought to follow what Brendan is...
Here's another thought to follow what Brendan is saying in regard to negative pressures. If the return runs through the space in which the appliance is located, when the filter gets dirty the leaks...
-
11-11-2005, 10:36 PM
Thread: fan & limit
by 7X- Replies
- 13
- Views
- 833
Another interesting thing about not clipping the...
Another interesting thing about not clipping the clip is that if the limit was intended to be 24 VAC and the secondary on the transformer is not grounded, nothing would burn up, the system will work...
-
05-25-2005, 08:52 PM
Thread: Fishing after Ice off for big trout.
by 7X- Replies
- 15
- Views
- 836
I have caught a lot of nice browns when I used to...
I have caught a lot of nice browns when I used to live in Colorado. Browns are nocturnal. Best fishing I have found is between 10:00 at night to 2:00 in the morning. Woolybuggers are fine or even...