  1. Thanks May! By return, I assume you mean the cold...

    Thanks May! By return, I assume you mean the cold air returns? If so, I just counted 8 of them total in the house and they all measured approx 15 X 7 inches? What you can't see in the pictures is...
  2. Heres one more looking away from the furnace: ...

    Heres one more looking away from the furnace:

    http://www.imagewiz.net/usr/hvac1/railway/12199_P1010005.JPG
  3. Ouch, that was large. I'll just post the links: ...

    Ouch, that was large. I'll just post the links:

    http://www.imagewiz.net/usr/hvac1/railway/12198_P1010011.JPG

    http://www.imagewiz.net/usr/hvac1/railway/12197_P1010009.JPG
    ...
  4. I was going on a trip to Florida but was delayed...

    I was going on a trip to Florida but was delayed so I thought I would give this a shot. I'm just learning how to do this.

    Bare with me if the first few are screwed up.
    ...
  5. I'll see what I can do, it may take a week or so...

    I'll see what I can do, it may take a week or so to get some posted but no promises.





    I think we went through a lot too as home owners. Itís not too much to ask that a job be done...
  6. Thanks for looking out Mark. This was fixed too....

    Thanks for looking out Mark. This was fixed too. They ran a new wire-pair to the senser direct from the stat. This freed up the purple wire to hook up W2. W2 was ran to W2.

    Before the tech...
  7. The re-work was performed this morning in force. ...

    The re-work was performed this morning in force. Everyone had the attitude they were going to school....lol. Actually there is a lot of truth in this. I found out the tech and owner called train...
  8. Had my meeting this morning and it went fairly...

    Had my meeting this morning and it went fairly well. The owner agreed the install wasn't good and will do the tasks recommended. He didn't even hesitate at changing the line-set again either. He...
  9. I really want to thank everyone for their...

    I really want to thank everyone for their comments. I especially want to thank Mark, you are very knowledgeable and it shows. Youíve taught an EE a few things about control wiring. BTW, I now get 8...
  10. I most agree, He nailed how my blower would work...

    I most agree, He nailed how my blower would work from my crude attempt to display my current wiring.

    After looking at 4 sets of wiring diagrams (t-stat, furnace, and 2 with the 16i) and reading...
  11. I still have time to sign up for this. Before...

    I still have time to sign up for this. Before the install, I would have said no, normally extended warranties aren't a good bargain. However, I must admit in my case now, this is a no-brainer
  12. LOL, .well, actually, the service manager said he...

    LOL, .well, actually, the service manager said he would want me to work for him when he left on the first day and the owner told my wife he wished he could hire me when she talked to him too the...
  13. I also remember talking to the owner of the...

    I also remember talking to the owner of the company about this too. Actually, he went to the school himself. Guess he should of been out here doing my startup. I don't blame the guys doing the...
  14. Thanks!!!! This makes perfect sense. What I...

    Thanks!!!! This makes perfect sense. What I didn't mention in my original post, I did watch the CFM LED during low cool. It only flashed 6 times for 600 CFM. I thought it should have been higher....
  15. Actually, not the lowest bid. He did the load...

    Actually, not the lowest bid.

    He did the load calcs. The owner went over the installation of the system with me before hand. He spent time with me answering questions. Said he wouldn't accept...
  16. Reading is nothing new. I seem to be the only...

    Reading is nothing new. I seem to be the only one doing any reading so far in this process. The techs sure haven't done much reading so far.
  17. I guess this comes down the "Golden Rule". "He...

    I guess this comes down the "Golden Rule". "He who has the gold rules".

    I haven't paid for the system yet.

    I'm looking for some sound resonable technical advice that is fair to both sides.
  18. Thanks Wirenut, I hope I can get them resolved...

    Thanks Wirenut, I hope I can get them resolved too.

    What would be a reasonable remedy to the improper start up my AC received? Iím not too worried about most of the poor workmanship. However,...
  19. Thanks BaldLoonie, nope, they didn't pull a...

    Thanks BaldLoonie, nope, they didn't pull a vacuum at all until much later in the process but did purge and pressure check with nigrogen after leak fixed. So, what is the result of charging with...
  20. Location: Missouri Equipment Installed:...

    Location: Missouri

    Equipment Installed:
    - TUY100R9V4W (FURNACE XV90)
    - 4TTX6036A (CONDENSER XL16i)
    - RXC037S3 (EVAPORATOR)
    - TCONT802A (T-STAT)
    - UltraVation Progressive Media Air Cleaner...