  1. Replies
    12
    Views
    412

    Pull plate off motor and look on backside

    Pull plate off motor and look on backside
  2. Replies
    11
    Views
    542

    I might add, when cleaning that pilot, with the...

    I might add, when cleaning that pilot, with the pilot in your hand and he orifice removed, look thru thru and you will see a venturi. About midway there is a hole that can become linted and affects...
  3. Replies
    30
    Views
    1,460

    You want them all to be just a cap

    You want them all to be just a cap
  4. Does the noise appear before the blower starts?...

    Does the noise appear before the blower starts? If yes it may be an undersized flex connector
  5. Replies
    14
    Views
    758

    Sounds like time to try the old screwdriver to...

    Sounds like time to try the old screwdriver to the ear and try to pinpoint area
  6. Replies
    43
    Views
    3,973

    I didn't read all the posts, maybe someone...

    I didn't read all the posts, maybe someone already mentioned the time honored coffee can repair.
  7. This is where I am, retired and my wholesale...

    This is where I am, retired and my wholesale company went out. So I buy off the internet, not very often do I need anything though.
  8. Replies
    10
    Views
    637

    I just went on EBay and they have many solenoid...

    I just went on EBay and they have many solenoid valves and coils.
  9. Replies
    10
    Views
    637

    Are you able to send a picture of the entire...

    Are you able to send a picture of the entire control area and the furnace
  10. Replies
    10
    Views
    637

    Are trying to find a replacement? Maybe easier to...

    Are trying to find a replacement? Maybe easier to remove all the controls and either convert to millivolt or 24 volt since you have line voltage for the transformer. I know most will answer sell a...
  11. Replies
    14
    Views
    1,380

    Company policy was to change any copper pilot...

    Company policy was to change any copper pilot tubing we found. Seems all had some degree of sulphate restriction. I have found many copper connectors with the flares gone and choked to the point of...
  12. Replies
    32
    Views
    2,331

    Some jobs are 4 tens and people love it. Actually...

    Some jobs are 4 tens and people love it. Actually they get to work their day off for overtime and still have the weekend free
  13. Replies
    23
    Views
    2,231

    Several years ago our local Johnstone had a...

    Several years ago our local Johnstone had a female working the counter. She was the in house expert on motors.
  14. Replies
    12
    Views
    674

    I drain the water lines and leave stat at 55 in...

    I drain the water lines and leave stat at 55 in Portland Oregon area
  15. Replies
    13
    Views
    810

    Same as keeping jumper in green-yellow and...

    Same as keeping jumper in green-yellow and yellow-white at the same time. Keeps coil pulled in
  16. Replies
    13
    Views
    810

    You may want to take the pilot out of the system...

    You may want to take the pilot out of the system for testing. Unplug the molex plug. Install a jumper in the green and yellow holes. After pilot lights remove jumper and install in the white and...
  17. Replies
    6
    Views
    547

    What appliance are asking about and what is the...

    What appliance are asking about and what is the delivery pressure from the meter? If nat gas probably 7".
  18. Replies
    17
    Views
    1,439

    Testing a millivolts system is a little different...

    Testing a millivolts system is a little different from a 24volt system. You must know the values of various pilot generators, what reads to expect across the different test points. What read would...
  19. Replies
    7
    Views
    772

    I think you are correct. They took over the old...

    I think you are correct. They took over the old General Controls co.
  20. Replies
    8
    Views
    344

    Norton igniter. 3.2-3.6 amps Carborundum 2.5-3.0...

    Norton igniter. 3.2-3.6 amps
    Carborundum 2.5-3.0
    You need to take an amp reading
  21. Replies
    7
    Views
    772

    An open read is pretty much useless unless it is...

    An open read is pretty much useless unless it is low. I've seen thermocouples show an open read of 21-22 or so and show 0-1 under load. Remember the values such as 30mv. 250mv. 750mv are open reads...
  22. Replies
    12
    Views
    1,574

    My SWAG is a dirty pilot or restricted orifice

    My SWAG is a dirty pilot or restricted orifice
  23. Replies
    16
    Views
    1,190

    Millivolt systems can be tricky if you have...

    Millivolt systems can be tricky if you have limited experience with them. First you need to know the types of pilot generators and their ratings. Next where to take reads , what they mean and what...
  24. Replies
    48
    Views
    4,145

    What, thermocoupler ?

    What, thermocoupler ?
  25. Replies
    22
    Views
    1,889

    Four items put DNP products into continuos fan...

    Four items put DNP products into continuos fan and no heat
    1-bad transformer 2-open limit/rollout switch 3-open fuse link 4- bad board
  26. Replies
    2
    Views
    346

    Spark generator for a 3 wire system??

    Spark generator for a 3 wire system??
  27. Thread: 60s what is it?

    by mike3
    Replies
    35
    Views
    2,529

    Magic Chef

    Magic Chef
  28. Replies
    11
    Views
    929

    I had the filters across the back of the truck on...

    I had the filters across the back of the truck on top of old metal file drawers I used for fittings. Seemed to work pretty well, open double back doors and they were right there.
  29. Replies
    22
    Views
    4,951

    Speaking of old Lennox units, who remembers the...

    Speaking of old Lennox units, who remembers the in-wall unit, no blower, millivolt system. Sorry I don't have a model number. If memory serves me it was rated at 50,000.
  30. Replies
    22
    Views
    4,951

    [/B] Landmark Series Replaced several hx...

    [/B]

    Landmark Series
    Replaced several hx sections in horizontals. Was pretty quick
  31. Replies
    19
    Views
    1,539

    Keep it going, I've worked on zillions of those....

    Keep it going, I've worked on zillions of those. Love them, easy to troubleshoot and pretty much bulletproof.
  32. PG-9 open read factory fresh-750mv G-250...

    PG-9 open read factory fresh-750mv
    G-250 -------------------------250mv
    PG-1---------------------------320mv
    With the thermostat calling for heat, take reads at the gas valve as follows. 1-...
  33. Replies
    32
    Views
    3,572

    Nobody has mentioned energizing the tstat and...

    Nobody has mentioned energizing the tstat and have the blower come on after a few seconds when the gas is off. That is a sure indication there is a "heat assist" fan switch (control) installed.
  34. Replies
    8
    Views
    838

    One problem that occurs is a power outage. If...

    One problem that occurs is a power outage. If the furnace is in operation at the time of the outage the limit will open.
  35. Thread: What be it?

    by mike3
    Replies
    23
    Views
    2,091

    Fraser-Johnston

    Fraser-Johnston
  36. Replies
    32
    Views
    3,572

    Wrong terminology used here. It is not a heater...

    Wrong terminology used here. It is not a heater for the LIMIT. Camstat was one of the mgf's. They had 6 wire controls and 4 wire controls. Lennox and DNP used them several years ago, before...
  37. Replies
    8
    Views
    1,329

    Hasn't run in 10 years, heck yes there is a...

    Hasn't run in 10 years, heck yes there is a spider in there
  38. Replies
    30
    Views
    3,639

    Bingo, I taught our guys to take proper reads...

    Bingo, I taught our guys to take proper reads FIRST and then if in doubt use jumper and screwdriver and also take read from that.
  39. Replies
    25
    Views
    2,323

    Won't be the fuse link, that puts blower into...

    Won't be the fuse link, that puts blower into continuous operation and nothing else.
    hmm got to think a bit. Have you tried bypassing thermostat?
  40. Replies
    41
    Views
    5,541

    We supplied all of our guys with this tool. ...

    We supplied all of our guys with this tool. Although the one the guys had when I started in the mid sixties were a better quality.
  41. Replies
    12
    Views
    2,051

    Years ago Lennox came out with a service bulletin...

    Years ago Lennox came out with a service bulletin that said to wash area where soap was used with clear water.
  42. Replies
    15
    Views
    2,040

    Sounds like you have a classic "floating" flame. ...

    Sounds like you have a classic "floating" flame. Poor venting, clear the HX of crap. It is restricted and not allowing the products of combustion to vent and the flame is recirculating seeking...
  43. Replies
    41
    Views
    5,541

    Pilot orifice cleaning tool(s) we used to have...

    Pilot orifice cleaning tool(s) we used to have "stick drills" that came in "MTD" sizes that were great
  44. Replies
    2
    Views
    838

    I'm thinking that is a left over coil from a...

    I'm thinking that is a left over coil from a hydraulic thermostat on a gas valve. The coil reacts to temp and the gas valve responds.
  45. Replies
    12
    Views
    1,577

    When I get confused I put power to the load and...

    When I get confused I put power to the load and the start by breaking a wire to add a switch to control on/off and then break wire again to add a limit then break wire again if I want a thermostat. ...
  46. Sounds like Testo has treated you as a valued...

    Sounds like Testo has treated you as a valued customer. We have returned instruments to fieldpiece and always got a different in return. One that came back had a previous owners name etched in the...
  47. Man, I can't believe all the stories here. ...

    Man, I can't believe all the stories here. After reading these posts why anyone would wait is beyond me. Keep this thread alive, it might mean you live.
  48. We took our dog in today for an endoscopy and...

    We took our dog in today for an endoscopy and they found some troubling inflammation and dark spots in his esophagus and stomach. They took a bunch of biopsies and we will get results in a week.
  49. Replies
    118
    Views
    14,819

    26

    26
  50. Thread: Thermocouple

    by mike3
    Replies
    31
    Views
    2,035

    you are quite right, however it only shows an...

    you are quite right, however it only shows an open read. Actually in the whole scheme of tcouples and valves it only indicates your meter is on the proper setting and operating.
    Please read post #26