  1. I want to put a little pipe dope on the stem, but...

    I want to put a little pipe dope on the stem, but also want to see it happen again to see what is really going on.
  2. Very interesting, never taught this was even a...

    Very interesting, never taught this was even a possibility. The rack is about 50 HP, about 10 years old, with no excessive vibrations, other than normal rack vibrations. But with the right...
  3. Sporlon Refrigeration Solenoid Stem Moving?

    On a supermarket rack system we had a Sporlon cool gas solenoid (1 line in 1 line out, mounted vertically, coil up) stuck open feeding gas to a circuit of about 20 freezer doors. A co worker ordered...
  4. Replies
    10
    Views
    1,157

    Thank you for your replies.

    Thank you for your replies.
  5. Replies
    10
    Views
    1,157

    Let me reword the last line. I don't think the...

    Let me reword the last line.
    I don't think the installers intended to pipe a trap they just piped it that way to get around the obstacle.
  6. Replies
    10
    Views
    1,157

    Sorry for the confusion, I haven't explained...

    Sorry for the confusion, I haven't explained well enough. The drop leg line (liquid line) comes down the condenser coil to the roof 4', travels along the roof then up 1' (around obstacle) then...
  7. Replies
    10
    Views
    1,157

    Yes. except backwards.

    Yes. except backwards.
  8. Replies
    10
    Views
    1,157

    Drop leg pipping

    On a 60 HP r507 refrigeration rack, The piping from a rooftop condenser to the indoor receiver, does the drop leg have to have a continuous drop to the receiver or can it have a 1' rise then drop...
  9. Replies
    1
    Views
    1,001

    Taylor C602 shake not filling

    :gah:I am working on a Taylor C-602 unit and have a problem where the cup is only filling 1/2 full on the shake side, fills for about 2-3 seconds, well below sensor level. I have already replaced...
  10. Replies
    9
    Views
    3,018

    thanks for the help, sorry I didn't update but it...

    thanks for the help, sorry I didn't update but it was a connector to the back of the board.
  11. Replies
    5
    Views
    858

    Thank for the advice. Looks like we'll be eating...

    Thank for the advice. Looks like we'll be eating the compressor and pricing a new condenser unit. (med temp this time)
  12. Replies
    5
    Views
    858

    Thank you PVC1984 for the info. Compressor is 3...

    Thank you PVC1984 for the info. Compressor is 3 phase. Sorry for the incomplete info.
  13. Replies
    5
    Views
    858

    Low temp compressor in med temp app.

    I was wondering if anyone could help. A coworker ordered a compressor for a walk in cooler TXV r12 1-ton C-charge, 12000 btu evaporator WJ-120-B. The compressor was a direct replacement for the...
  14. Replies
    11
    Views
    1,547

    Sounds weird but whatever works. But I suspect...

    Sounds weird but whatever works. But I suspect the wax will ware out in a couple of months.
  15. Replies
    33
    Views
    3,638

    :cheers:Sounds like you figured it out. Someone...

    :cheers:Sounds like you figured it out. Someone mentioned the grasslin timer. The relays burn up from the compressor load. We've been adding external relays on those true boxes if they don't...
  16. Replies
    30
    Views
    3,036

    I started pushing carts at a large supermarket...

    I started pushing carts at a large supermarket then became the manager, quit, started as 1st step apprentice then became general foreman so I see both sides. These two occupations have completely...
  17. Replies
    25
    Views
    2,410

    I apologize. Never meant any disrespect to any...

    I apologize. Never meant any disrespect to any remanufacturer. In fact I stated most of them have been very helpful. I take every precaution when installing a compressor reman, rebiult or new. ...
  18. Replies
    24
    Views
    3,479

    Have to admit, never used R22 as a flushing agent...

    Have to admit, never used R22 as a flushing agent but I heard this being done before. I can see why compressor manufacturers wouldn't recommend other "chemicals" damaging their compressors. ...
  19. Replies
    7
    Views
    833

    Soda machines have removable nozzles which...

    Soda machines have removable nozzles which require daily cleaning by staff. Unfortunately some establishments fail to clean these and they develope a seaweed like growth which is pretty nasty. Ice...
  20. Thread: Revco freezer

    by western
    Replies
    0
    Views
    380

    Revco freezer

    Working on a revco -80 freezer ult2586. 1st stage restricted. Took off liquid and suction line flushed through with rx11 and nitrogen. Clogged and first then blew threw pretty good. replaced...
  21. Thread: hoshi

    by western
    Replies
    24
    Views
    2,125

    agree, sounds like plate separation. Get a new...

    agree, sounds like plate separation. Get a new icemaker.
  22. Replies
    15
    Views
    1,968

    I guess for long shutdowns or a start up on a...

    I guess for long shutdowns or a start up on a package unit when the system never got a chance to pump down then by turning on the heater for a day before start up will keep the liquid out of the...
  23. Replies
    17
    Views
    2,156

    Another very important thing is to check the...

    Another very important thing is to check the cleanilest and integrity of the blower wheel. Especially on older units. Bearings, motors, pulleys may be availiable locally but shipping in an oem...
  24. Replies
    21
    Views
    2,364

    Used nylog about 3 years ago to seal a crankcase...

    Used nylog about 3 years ago to seal a crankcase bolt on a military type a/c unit to cool commercial airlines. Haven't leaked yet. But also used it for a suction transducer at a supermarket and it...
  25. Replies
    24
    Views
    3,479

    Just used it today to flush out stainless steel...

    Just used it today to flush out stainless steel (non acr) lines (Rx11). I agree you have to have some kind of restriction on the back end to biuld up pressure. I also wonder how well it does on some...