Search:

Type: Posts; User: farbeondriven

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Replies
    52
    Views
    2,622

    http://www.getnitrogen.org/pdf/graham.pdf ...

    http://www.getnitrogen.org/pdf/graham.pdf

    Written by air products though. Lol
  2. Replies
    52
    Views
    2,622

    I'm certain the gimmick was n2 molecules are...

    I'm certain the gimmick was n2 molecules are larger than o2 molecules and wouldn't permeate as easily.
  3. Replies
    1
    Views
    216

    How to post a PDF?

    I can't seem to get a PDF file to load up on here. Tried searching as well but no results.
  4. Replies
    16
    Views
    1,327

    ranging anywhere from 20-35 would be my guess for...

    ranging anywhere from 20-35 would be my guess for an average for od temerature at night
  5. Replies
    16
    Views
    1,327

    yes electric water heater.......I know when the...

    yes electric water heater.......I know when the aux heat is on and off as I cycled all the controls and confirmed via amp draw
  6. Replies
    16
    Views
    1,327

    Actually checked them unwired from elements after...

    Actually checked them unwired from elements after I noticed only 25 amps on L1....Physically pulled heaters and found the break.....Sequencer works as it should
  7. Replies
    16
    Views
    1,327

    Energized with defrost....does not run with call...

    Energized with defrost....does not run with call for heat unless stat starts to lag and differential is met
  8. Replies
    16
    Views
    1,327

    His highest bills were 250-300 for the past 10...

    His highest bills were 250-300 for the past 10 years....Last 2 months were 5-600....
  9. Replies
    16
    Views
    1,327

    Could this thread be moved to pros residential...

    Could this thread be moved to pros residential area please....I posted in wrong area.....Thanks
  10. Replies
    16
    Views
    1,327

    to clarify "losing ground" bad choice of...

    to clarify "losing ground" bad choice of words......The house temp would fall more during defrost cycles and house temp would be even further from satisfying.....
  11. Replies
    16
    Views
    1,327

    Heat Pump Aux heat question....

    Had a customer call in with excessivly high electric bills.....I checked charge, coils, defrost operation and sensor, tstat and Electric heater banks.....

    Only thing I found was one element on 10k...
  12. Replies
    3
    Views
    1,751

    water source ductless?

    Hello guys.....I have a customer inquiring about a ductless system.....He would like to go geothermal also.....

    I can get floor mounted self contained console unit's thru climate master but the...
  13. Replies
    10
    Views
    2,649

    I've had success with the loop conditioner on...

    I've had success with the loop conditioner on leaks that needed charged once a year......Its worth trying before changing everything over.......I just use a push pull pump to get it in and leave...
  14. Replies
    22
    Views
    2,093

    Do they make 3 inch? I've only used up to 2 inch...

    Do they make 3 inch? I've only used up to 2 inch which is r8.......

    Ductboard is all we use around here.....yea I'd like to do sheet metal but we would always get beat out on pricing.......I've...
  15. Ive noticed that climate master has the all...

    Ive noticed that climate master has the all aluminum air coil.....they used to have one that was coated.....was that the tin coating? Was all black

    formicary corrosion? is that fancy words for...
  16. You should be happy with CM......30,000 seems...

    You should be happy with CM......30,000 seems like an awful lot to just replace the units or did you have earth loop work done also?
  17. hhhhmmmmmm I bet your not flowing thru all...

    hhhhmmmmmm I bet your not flowing thru all circuts... First thing you need to do is flush with a cart and pressure test...I don't personally beleive a non pressurized system is good enough to purge...
  18. Replies
    84
    Views
    12,042

    You knew what I was talking about...slick

    You knew what I was talking about...slick
  19. Replies
    84
    Views
    12,042

    the collector is a compressor also....i wonder if...

    the collector is a compressor also....i wonder if a lack of thermal dump of some sorts may have been why flared joints failed...it gots to hot...maybe not controlled properly among other things..the...
  20. Replies
    3
    Views
    1,527

    Did you here any change in the sounds from the...

    Did you here any change in the sounds from the compressor and amp draws when jumping r directly to y2 with a jumper? You may wanna contact Climate Master first I though I read in there newsletter...
  21. Replies
    3
    Views
    1,963

    I agree with the loop conditioner....used it once...

    I agree with the loop conditioner....used it once on a job we picked up from our local hackers club...slow leaker about once a year needing recharged..put in conditioner and its been 3 years and...
  22. Whats the heat of rejection? Its possible the...

    Whats the heat of rejection? Its possible the loop is undersized but also possible your only flowing through some circuts...Could be piped incorrectly or need flushed with a cart...
  23. id forget about the pex and wraping it all...

    id forget about the pex and wraping it all up....why not just use a coil of well pipe?

    Id like to try taking an old refridge or freezer and setting a tank inside painted black then a sliding glass...
  24. it has been my experience that the source in and...

    it has been my experience that the source in and load in can tie in at the same point at the bottom of any tank, least thats what ive been told on here and by climate master.
  25. Good call. Ive seen this with the ewc zone...

    Good call. Ive seen this with the ewc zone controls where the only control of the aux heat was based on a time setting. Based on the op's posting is does seem to be timing out thru the stages...
  26. find the breaker that controls the power supply...

    find the breaker that controls the power supply to the aux heaters turn it off and then see if the unit is capable of doin the job on its own. Unless you r close to design temp you shouldnt need the...
  27. you would recoop the cost particularly if you are...

    you would recoop the cost particularly if you are overadiated at all. the logic is to run the circulator continously and keep the water temp low as possible. The compressor will just cycle to...
  28. water heater tank? load in goes to bottom of...

    water heater tank?
    load in goes to bottom of tank
    load out goes to cold inlet on top of the tank (i remove the dip tube)

    house load out comes off hot outlet on top
    house load in goes to t at...
  29. Thread: pond.

    by farbeondriven
    Replies
    14
    Views
    3,298

    could you elaborate on this hyper loop? I've...

    could you elaborate on this hyper loop? I've been hearing about it and very curious.
  30. ditto. Hell I've heard of guys using windshield...

    ditto. Hell I've heard of guys using windshield washer fluid in geo systems. We always buy the premix 5 gal pails of methanol from our equipment supplier.
  31. Replies
    24
    Views
    5,345

    i talked to a man that sold WF for years and...

    i talked to a man that sold WF for years and switched to climate master because WF was getting out of control with complicated circut boards and controls mainly on the envision model, i guess. Any...
  32. Ive seen these before and think there a really...

    Ive seen these before and think there a really cool set up. My only thing is bringing the manifold inside and having vlvs. on each loop. I generally like to keep them burried where i dont have to...
  33. awesome pics. I do residential and light...

    awesome pics. I do residential and light commercial. I really wanna get into and learn commercial and industrial stuff someday.
  34. Replies
    8
    Views
    1,591

    We always back fill the entire colum. water or...

    We always back fill the entire colum. water or not.
Results 1 to 34 of 1000
Page 1 of 20 1 2 3 4

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event