  1. Replies
    37
    Views
    11,225

    What software version

    What software version
  2. Replies
    177
    Views
    26,351

    The application is still there you probably will...

    The application is still there you probably will have to go back to device manager and re sect for each device
  3. Replies
    18
    Views
    2,063

    Check your general system settings and make sure...

    Check your general system settings and make sure there are devices in the device mAnager.
  4. Replies
    177
    Views
    26,351

    Tried using hyper terminal ? Password shod be...

    Tried using hyper terminal ? Password shod be pass
  5. 1.3 would be bactalk, I dont think the usb keys...

    1.3 would be bactalk, I dont think the usb keys are backward compatable. backtalk used a serial key. I have a couple
  6. Replies
    3
    Views
    824

    code has nothing to do with the network numbers. ...

    code has nothing to do with the network numbers. The code lives as a .bd4 file in the data base on your server.....Writing global subcaller code is not as easy as writing vlc code.

    What are...
  7. Replies
    10
    Views
    1,394

    Correct

    Correct
  8. Replies
    10
    Views
    1,394

    The BTW-KEY-3 BACTALK FOR WINDOWS is probably a...

    The BTW-KEY-3 BACTALK FOR WINDOWS is probably a serial key and will only work with bactalk for windows. Envision for bactalk or "EBT" uses a usb key so it would say ebt on it.
  9. Replies
    4
    Views
    880

    Had the same issue with a aaon with honeywell...

    Had the same issue with a aaon with honeywell excell controls. 5 units altogether but only on would cause the BAS to have excessive com errors. Tried swapping drives, blah, blah, blah, ended up...
  10. Replies
    3
    Views
    922

    Are you tring to send it via visio or device...

    Are you tring to send it via visio or device manager?
  11. Ebt nor web talk 2.01 are 7 compatable. You will...

    Ebt nor web talk 2.01 are 7 compatable. You will have to upgrade to abs 3.0 it has we talk built into it and the software key is no longer they have gone to a license.
  12. How many devices are already on the network?

    How many devices are already on the network?
  13. What are the MAC adresses of each? True on...

    What are the MAC adresses of each?

    True on the resistors

    no. It hooks up just like a 8000
  14. Yes, the provider will spit it out as a text.

    Yes, the provider will spit it out as a text.
  15. Replies
    15
    Views
    3,453

    The file is to big to email. Im working on a...

    The file is to big to email. Im working on a file sharing web site, I havnt got it on there yet will let you know if it works or you could pm me
  16. VEGA EBT or most if not all monitoring...

    VEGA



    EBT or most if not all monitoring software has to send the text via tap modem number, and then your provider routes the message to your phone. The tap modem number is not your phone...
  17. Just last week I set up a customer who has ntelos...

    Just last week I set up a customer who has ntelos as there provider, ntelos provided me with tap modem number, but said that they did not support these numbers.... Ok....Thanks for the support. The...
  18. Replies
    15
    Views
    3,453

    Shylock What version was the customer running....

    Shylock

    What version was the customer running. Is the software key USB or serial.
  19. Also check the ms/tp mac setting(not to be...

    Also check the ms/tp mac setting(not to be confused with the mac address/dip switches) at the carel device. The bcm is typically set at 0, you might need to play with that number at the carel...
  20. Do a devivce scan. Are there any forgien devices...

    Do a devivce scan. Are there any forgien devices that show up? Most vlc devices communicate at 78.6, what speed is the bcm set up for?
  21. Replies
    5
    Views
    959

    Most definitly each Bcm should host the devices...

    Most definitly each Bcm should host the devices that live beneath it, the way they have it set up there is gonna be alot of network traffic across networks, which tends to slow down traffic, and can...
  22. Replies
    5
    Views
    959

    What kind of problem are you experiencing?

    What kind of problem are you experiencing?
  23. Replies
    5
    Views
    959

    Yes Do transfers result in BACnet...

    Yes



    Do transfers result in BACnet traffic? YES


    i.e. is a 'Transfer' to another device a WriteProperty and a 'Transfer' from another device a ReadProperty? NO
  24. Replies
    4
    Views
    1,061

    buf, you need to update your profile

    buf, you need to update your profile
  25. Thread: Alerton

    by doubleduece
    Replies
    3
    Views
    700

    Make your bti has a ROC file that is up to date...

    Make your bti has a ROC file that is up to date for ebt 2.6
  26. Replies
    4
    Views
    1,061

    you need to put a email in your profile.

    you need to put a email in your profile.
  27. Replies
    12
    Views
    960

    I meant did it ever transfer OA?

    I meant did it ever transfer OA?
  28. Replies
    12
    Views
    960

    Did this program ever work?

    Did this program ever work?
  29. Replies
    177
    Views
    26,351

    The password could be anything and is set the...

    The password could be anything and is set the first time you launch ebt after installation. You would have to backup ebt, uninstall ebt and reinstall ebt(if you have a software disk). Launch ebt...
  30. Replies
    12
    Views
    960

    When you say reflash, what procedure r you using....

    When you say reflash, what procedure r you using. you should never have to reflash a bcm once the program is installed. What version is your ROC file? Maybe the program stopped running or halted,...
  31. Your system should be piped primary/secondary,...

    Your system should be piped primary/secondary, and I sure it is. When you say post purge, that usually means how long a comb. fan runs after the gas valve turns off. Im sure you mean how long the...
  32. Replies
    23
    Views
    2,123

    What are the pressures and refig.? ...

    What are the pressures and refig.?


    Uncondensables??


    Fouled tubes maybe?
  33. A bad sensor. What is the delta T on the MP2...

    A bad sensor.

    What is the delta T on the MP2 compared to the boiler display when the boiler is running?

    What is the Delta T on the MP2 when the boiler is not running?

    how many stages do...
  34. Replies
    15
    Views
    2,725

    You can pick up a cheap router at...

    You can pick up a cheap router at http://www.ccontrols.com/building.htm.

    Visio is the preferred way to write code, but it has to have been installed before EBT for it to function properly with...
  35. Replies
    15
    Views
    2,725

    I think I just broke a rule........ Sorry mods...

    I think I just broke a rule........ Sorry mods...
  36. Replies
    15
    Views
    2,725

    list price is 2 strong

    list price is 2 strong
  37. Replies
    15
    Views
    2,725

    You have to buy it through a dealer, not cheap.

    You have to buy it through a dealer, not cheap.
  38. Replies
    80
    Views
    18,480

    You have to buy it through a dealer, not cheap....

    You have to buy it through a dealer, not cheap....
  39. Replies
    15
    Views
    2,725

    Yes Vlc's with ROC file v4.02 or later(this...

    Yes Vlc's with ROC file v4.02 or later(this version was released in 20o5 can share data using the WED(Write to External Device) and the RED(Read from External Device) functions, when using them you...
  40. Replies
    15
    Views
    2,725

    If visio was properly installed all of the visual...

    If visio was properly installed all of the visual logic functions should be there
  41. Replies
    15
    Views
    3,453

    A 2.5 key will not work below 2.01 but will work...

    A 2.5 key will not work below 2.01 but will work with 2.6
  42. Replies
    80
    Views
    18,480

    SamTam What r u lookn 4

    SamTam What r u lookn 4
  43. Replies
    15
    Views
    2,725

    The REDS and WEDS are the way to go if you dont...

    The REDS and WEDS are the way to go if you dont have a bcm, but use them sparingly because they slow down the communications on the segments where the devices live. Is is explained in the...
  44. Replies
    20
    Views
    2,262

    Trane sucks!!!!!! Miss ya!!!!!!!

    Trane sucks!!!!!! Miss ya!!!!!!!
  45. Replies
    15
    Views
    3,453

    Become a Alerton dealer or associate...

    Become a Alerton dealer or associate dealer.:cheers:
  46. Replies
    19
    Views
    4,280

    WRONG When the unit switches the motor speed...

    WRONG

    When the unit switches the motor speed it uses a relay to switch from on speed to the next. To run the motor on high speed switch the the high and mediums speeds, easy peazy, lemon squeezy.
  47. Replies
    2
    Views
    733

    Lochnvar has a solid platform of boilers to meet...

    Lochnvar has a solid platform of boilers to meet any buildings need. You just need a good sales rep yo sell the right package. How many boilers does your campus require?
  48. Replies
    2
    Views
    452

    You could have BCM config issues, device config...

    You could have BCM config issues, device config issuse software config issues, trunk issues, are eol resistors installed, polarity correct everywhere, if it lives on a network, network issues. Its...
  49. Replies
    15
    Views
    2,725

    Are you sure the input is kaput and not the...

    Are you sure the input is kaput and not the sensor? If it is AI0 with the microset living on it you have to replace the controller. After you launch the vlc emulator(blue screen) and set the device...
  50. Replies
    8
    Views
    2,168

    the training has to be set up through your local...

    the training has to be set up through your local dealer.