Search:

Type: Posts; User: david chamberla

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    17
    Views
    1,307

    THE ONLY HOSHI IVE EVER SEEN SLUSHI IS DCM WHEN...

    THE ONLY HOSHI IVE EVER SEEN SLUSHI IS DCM WHEN THEY 1ST CAME OUT HAD TO PUT TIMER ON THEM . ,
  2. Replies
    12
    Views
    1,290

    This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  3. Replies
    21
    Views
    1,919

    DO YOU SEE SOME OF THE ORFICE FROST I HAD TO...

    DO YOU SEE SOME OF THE ORFICE FROST I HAD TO REPLACE HEADER KIT .
  4. YOU HAVE RELIEF VALVES ON YOUR WATER OR GLYCALL...

    YOU HAVE RELIEF VALVES ON YOUR WATER OR GLYCALL CONDENSER THAT COULD RELEASE IF YOU DO THAT; I WOULD HOOK UP FLOW CONTROLE THAT IF I LOOSE FLOW MY BACK UP PUMP WOULD COME ON ,ALSO I WOULD TEST IT 4...
  5. Replies
    10
    Views
    1,223

    AFTER YOU PUT NEW GEAR BOX IN MAKE SHURE YOU...

    AFTER YOU PUT NEW GEAR BOX IN MAKE SHURE YOU BALANCE IT ALSO ALINE SHAFT CORECTLY OR YOU WILL BE REALING ON WOBLE SWITCH TO SAVE IT HAVE DUNN A FEW.FUN STUF GET A HOLD OF MARLY OR REP FOR SPECKS ON...
  6. Replies
    26
    Views
    2,587

    IF YOU HAVE MOISTURE IT WILL FREEZ AND ICE TAKE...

    IF YOU HAVE MOISTURE IT WILL FREEZ AND ICE TAKE TORCH HEAT UP IF IT GOES AWAY YOU HAVE MOISTER IT WILL BREAK LOOS LIKE ICE PLUGG ;
  7. Replies
    16
    Views
    1,517

    GET AHOLD OF WATER TREATMENT PEOPLE THERE WATER...

    GET AHOLD OF WATER TREATMENT PEOPLE THERE WATER TREATMENT CONTROLLER MIGHT BE OVER FEEDING CHEMICALL
  8. Replies
    5
    Views
    1,282

    might wont to check on new evap .easer saID THEN...

    might wont to check on new evap .easer saID THEN DUNN
  9. Replies
    11
    Views
    1,727

    RUNDAWS IVE WORKED WITH SO MANY PEOPLE THEY SAY...

    RUNDAWS IVE WORKED WITH SO MANY PEOPLE THEY SAY BETTER LUCK THAN SKILL .I LIKE ,INSTEAD OF LEARNING TRICKS OF THE TRADE LEARN THE TRADE SO TRUE ...
  10. Replies
    20
    Views
    3,059

    R.S.E.S HAD A NICE TRAINING 'HIGH VOLTAGE WERE...

    R.S.E.S HAD A NICE TRAINING 'HIGH VOLTAGE WERE THYE ACTUALY USED LIVE VOLAGE AND CARBON ARCH FRIED HOT DOGS AND MADE FIREWORKS DISCUSED HOT STICKS AND FLAME SUITES LOCK OUT TAG OUTS 4160 DOWN TO 120...
  11. Replies
    28
    Views
    3,052

    if you charge to full sight glass you take good...

    if you charge to full sight glass you take good chance on a overcharge if you have a txv and the box is warm . i like sight glasses use full,
  12. Replies
    42
    Views
    4,317

    3 phase moter will have resistance the same on...

    3 phase moter will have resistance the same on all 3 legs .If not moter bad ,which i worked on a older trane which was a 208 230 volt 3 phase which hinding in the corner was a step up transfprmer 460...
  13. Replies
    14
    Views
    1,294

    just got done with weilmclane boiler with a wayne blue angel burner clean as can be

    :angel:
  14. Replies
    3
    Views
    1,341

    i have got my oven gas valves from haritage food...

    i have got my oven gas valves from haritage food . if you need a 1800 3 let me know .they have got a lot of even steam kettle parts;refer parts .
  15. Replies
    9
    Views
    1,301

    thank you invertor was speeding up to compensate...

    thank you invertor was speeding up to compensate for refrigerant waighed out charge was short waighed back in .got up and running ,went back to leack search found leak in evaperator ,its on the way...
  16. Replies
    9
    Views
    1,301

    wow suction psi starts at 70 pounds than goes...

    wow suction psi starts at 70 pounds than goes to140 after it ramps up supper heat 20 deg .head psi stays at 290 psi subcool 5 .is clear as mud iam old school like to abrevate spelling allways...
  17. Replies
    14
    Views
    2,876

    hello skrewdriver spent 30 years in az still hold...

    hello skrewdriver spent 30 years in az still hold my phx lic there know in oh ,i hit those coils evap coil cleaner few cans also spray water bottles in those tuff location hey tailler freezer sales...
  18. Replies
    7
    Views
    940

    used 409a ranco a12 700 worked out good

    used 409a ranco a12 700 worked out good
  19. Replies
    9
    Views
    1,301

    server room troubles

    have a mitsubishi muya24na that when it ramps it at 70# gradualy goes to 140 sh 20 hp allway stays at 290 sc 5 amps on start up 6.7 goes as high as 7.5 out side temp 75 indoor 80 .when i first got...
  20. Replies
    50
    Views
    4,957

    put unit back to gether and put in vac weigh in...

    put unit back to gether and put in vac weigh in charge and take amps if it 3ph switch two wire ,if it is a scrolll comp you will have to make sure you do not leave like that . if it is stuck it...
  21. Replies
    15
    Views
    2,352

    had to retro mini new bin control from mechanical...

    had to retro mini new bin control from mechanical to thermostatic ,dont forget the bin braket.the extension.
  22. Replies
    15
    Views
    2,352

    got to to love it , midnight call

    got to to love it , midnight call
  23. Replies
    50
    Views
    4,957

    looking at manuel .place jumper t1 t2 2 contiuous...

    looking at manuel .place jumper t1 t2 2 contiuous seconds .allowing unit to energize ,the unit can now be scrolled through modes.when you remove jumper it will stay in that mode 1hr . if you need...
  24. Replies
    15
    Views
    1,722

    i have a infacom it has been the best one .had it...

    i have a infacom it has been the best one .had it 5 y and it still find lots of leaks ,changed diode once .pin holes that brands could not find
  25. Replies
    4
    Views
    1,050

    FIND OUT WHAT TOTAIL DUCT STATIC IS DIFERANT PART...

    FIND OUT WHAT TOTAIL DUCT STATIC IS DIFERANT PART OF THE SYSTEM. FIND OUT WHAT YOUR SC SHOULD BE 20 SOUND HIGH GET THAT AIR FLOW TD 30 HIGH AFTER AIR FLOW THAN YOU MIGHT FIND POSIBLY OVER CHARGE...