Search:

Type: Posts; User: saylor240

Page 1 of 20 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    0
    Views
    60

    IAQ/HVAC consultant

    I am considering starting my own business as a HVAC/Indoor air quality Consultant, I am looking for feed back and possible advise from a current consultant.. ( I know online we are all...
  2. Fujitsu Mini splits are superior when it comes to...

    Fujitsu Mini splits are superior when it comes to noise and vibration, even if a fan blade broke ( seen in many mini splits but not Fujitsu) the vibration would probably not be noticeable less your...
  3. Thread: Bad Damper?

    by saylor240
    Replies
    2
    Views
    132

    if you can locate the damper look at it and...

    if you can locate the damper look at it and listen to it...have someone activate the t-stat and see if there is any noise or sound change. do not dismantle it as there is voltage inside of it. on...
  4. Thread: Trash Night

    by saylor240
    Replies
    9
    Views
    246

    lots of little baggies and Empty "joker"...

    lots of little baggies and Empty "joker" packages? :eek2::eek2:
  5. Replies
    34
    Views
    618

    just like any other unit, weigh in charge very...

    just like any other unit, weigh in charge very critical in marine AC maybe more than most, like ice machine. weigh in charge, check proper water flow thru tube in tube coil, and amp draw. I have one...
  6. so you have filter at the hvac unit, but not in...

    so you have filter at the hvac unit, but not in the return grill? im guessing...if that is case i recommend a cheap blue (not pleated) on the return grill to catch large debris and pleated filter at...
  7. Replies
    5
    Views
    449

    going simple would be easy, are either units...

    going simple would be easy, are either units working at all now? sounds like you may have other issues. what type of programmable t-stats did you remove?
  8. Replies
    3
    Views
    243

    i got the samsung french door top and freezer...

    i got the samsung french door top and freezer bottom from lowes about a year ago, got the extended warranty from lowes.
    Unit great so far, you can set fridge and freeze temps, have dual cooling. we...
  9. Well tiger loop makes them, its required for a...

    Well tiger loop makes them, its required for a single pipe system. you do have to consider tank location. is the oil heater above or below the oil tank? when was the last time the tank was drained...
  10. Replies
    11
    Views
    444

    really should not be a problem, just buy one from...

    really should not be a problem, just buy one from a big box store that has a good return policy, then if it fails just bring it back...
  11. Thread: Goodman

    by saylor240
    Replies
    8
    Views
    432

    what is amp draw of the motor? this really...

    what is amp draw of the motor?
    this really first time you have seen a sequencer used for fan operation?
    Does the unit have electric heat?
    Does the unit only freeze when the fan is not running?
  12. there is a lot more than just capping off, Tank...

    there is a lot more than just capping off, Tank location, and if you worked on oil 30 plus you would know you would need a "device" installed to make it a one pipe.
  13. :grin2:

    :grin2:
  14. you can make it last longer by setting your...

    you can make it last longer by setting your thermostat at 78 instead of 72...I am guessing you have set at 72 due to your return temp. if you could set higher you could reduce energy bills and make...
  15. had issues with Trane coils years ago, was the...

    had issues with Trane coils years ago, was the coating on the coils...ask how much to change the indoor evap coil with new..
  16. Has any of the 3 done a proper load calculation? ...

    Has any of the 3 done a proper load calculation? Who ever you go with have everything in writing of what they are promising, so in the event you have issues in the future you have paperwork to back...
  17. Replies
    29
    Views
    883

    try and pump it down...

    try and pump it down...
  18. Replies
    7
    Views
    269

    I would like to know where they get 16 seer out...

    I would like to know where they get 16 seer out of that..
  19. Replies
    10
    Views
    2,278

    looks like it just needs new paint///

    looks like it just needs new paint///
  20. Replies
    3
    Views
    313

    no way he got in thru the PVC vent as it is a...

    no way he got in thru the PVC vent as it is a sealed burner chamber that does not allow flue gas to mix with your air return, yes the unit could have a bypass if it is a zone system it would be off...
  21. Replies
    51
    Views
    2,582

    New techs have it easy these days anyway, all the...

    New techs have it easy these days anyway, all the caps I see at the supply house say 370/or 440 and they have Turbo caps available.....Oh how i could have used some turbo caps 20 years ago on a...
  22. Replies
    31
    Views
    2,033

    Just a thought....have the Airflow been checked?

    Just a thought....have the Airflow been checked?
  23. Replies
    15
    Views
    792

    sparks could fly and board meltdown if it board...

    sparks could fly and board meltdown if it board failed and called for low/high motor speed at same time?...
  24. Replies
    16
    Views
    1,181

    i would get hoses with manual shut off 1/4 turn...

    i would get hoses with manual shut off 1/4 turn valves, almost no failure rate on those.
  25. Replies
    12
    Views
    323

    Access to a breaker panel should never be...

    Access to a breaker panel should never be block/restricted what if Muffy the cat chewed on electrical cord and was being shocked would you rather grab the cat or just shut off the breaker..
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4