    Good to see someone else out there that does it...

    Good to see someone else out there that does it right! Thanks flounder!
  2. Replies
    38
    Views
    8,228

    Re: Quality Install better than brand!

    Good point andrew!!!
  3. Replies
    33
    Views
    8,892

    Re: Re: Re: Re: OK

    Yeah, but Texas energy code requires 1/2 armaflex on drain lines inside a building, even or should I say especially in the attic. [/B][/QUOTE]

    I can see that since an attic is a non conditioned...
  4. Replies
    33
    Views
    8,892

    Re: Re: Clearance

    Well, you are correct, according to National Fire Code there shall be six inches clearance from combustibles when using single wall pipe, one inch when using "B" vent.
    But that isn't what I was...
  5. Replies
    33
    Views
    8,892

    Clearance

    Correct me if I'm wrong, but I'm pretty sure it's 6" clearance from the front of the furnace to combustibles. I'm not a Lennox dealer, but 6" is pretty much the industry standard on 80% gas furnaces.
  6. Replies
    10
    Views
    4,972

    BS?

    Have you ever used heresite? I have, and have gotten good results. No, it will not make the coil last forever, but will add years to the life it, and the cost to the equipment owner is more than...
  7. Replies
    38
    Views
    8,228

    Sorry Boss, and fellow members. I let a very...

    Sorry Boss, and fellow members. I let a very rough week get to me and ended up venting here in the forum. I realize this was not the thing to do, and will do my best not to let it happen again in the...
  8. Replies
    26
    Views
    6,135

    Actually, a single pole contactor costs more than...

    Actually, a single pole contactor costs more than a 2 pole, at least they do in this part of the country. Generally, manufacturers use them because they're cheaper than an insertion, or wrap around...
  9. Replies
    39
    Views
    11,980

    Get a life

    Hate to be a dick, but you need to get a life.
  10. Replies
    26
    Views
    6,135

    Look again.

    Look again.
  11. Replies
    38
    Views
    8,228

    [ deleted by Boss iceman2_us, read this...

    [ deleted by Boss

    iceman2_us, read this http://hvac-talk.com/vbb/showthread.php?threadid=36056

    you are way out of line

    ]
  12. Replies
    38
    Views
    8,228

    So....what's your point? By the way, ICP is now...

    So....what's your point? By the way, ICP is now owned by United Technologies, which is Carrier. You have the right to sell and install any brand you like, I happen to like York. Having been a dealer...
  13. Replies
    38
    Views
    8,228

    Absolutely! And you did do a very nice job!

    Absolutely! And you did do a very nice job!
  14. Replies
    38
    Views
    8,228

    Re: Re: Goodman?

    I installed several Goodman units in the past, had problems with all but one system. Biggest problem was coils springing refrigerant leaks. I dropped my Goodman dealership in 1992, and went to York....
  15. Replies
    39
    Views
    6,330

    Looks good

    Other than the electrical tape holding down what looks to be the hose from the condensate pump to the furnace vent, and I'm assuming that's the vent for a 90+ unit. Please tell me that was...
  16. Replies
    38
    Views
    8,228

    Goodman?

    Job looks great, but since when did Goodman equipment qualify for the hall of pride?
  17. Replies
    26
    Views
    6,135

    Single Pole Contactor

    They used a single pole contactor for a reason, the idea is, keep one leg to the compressor hot to act as a crankcase heater. Never said it was a good idea, but it does work.
  18. Replies
    9
    Views
    4,259

    Gotta do what you gotta do.

    Looks good.
    We've all cut corners when it comes to clearance, because, after all, it's an imperfect world.
  19. Replies
    33
    Views
    8,892

    OK

    [QUOTE]Originally posted by Steve Wiggins
    A return in every room is not doing it right, it is doing it old school. We have learned a lot about building science since then. [/QUOTE "Old school" or...
  20. Replies
    30
    Views
    12,056

    Vent

    [QUOTE]Originally posted by hvacdr
    no vent on condensate line? thatll get one day [
    /QUOTE]Why trap or vent a positive pressure coil? Unless code says you have to. Air is gonna push the water...
  21. Replies
    39
    Views
    11,980

    Nice

    Very nice work, and professional, right down to the uni-strut and clamps. Two thumbs up!!
  22. Replies
    33
    Views
    8,892

    Returns

    If you're going to do it, do it right and put a return in every room but the kitchen and bathroom. If nothing else, put in "jumper returns". If the customer wants comfort, they'll pay for it, if not,...
  23. Replies
    10
    Views
    4,972

    Coat The Coils

    When replacing the system, have the evaporator coil heresite coated before installing. It does not hamper heat transfer, and the coil will last for years.
  24. Replies
    4
    Views
    5,688

    Line Sizes

    Up-sizing the refrigerant lines for a 150' run would also help.