    well since u asked, i dont mind a y per duct but...

    well since u asked, i dont mind a y per duct but what i'm talking about is 3 or even 4 y's per duct. when i SAY PER DUct i mean the duct coming from plenum. and no dampers on those y's.
  2. Replies
    23
    Views
    1,631

    I like metal triangles, start collars with...

    I like metal triangles, start collars with dampers and I hate y after y with no dampers. And I cant stand ductboard.
  3. Replies
    23
    Views
    1,474

    i COME ACROSS THOSE MISMATCHED SYSTEMS EVERY NOW...

    i COME ACROSS THOSE MISMATCHED SYSTEMS EVERY NOW AND THEN WHEN THE GOAL IS TO DO MORE LATENT COOLING. THAT NEW COIL COMES WITH A TXV INSTALLED I USUALLY SWAP TXV WITH ONE THAT MATCHES CONDENSER...
  4. Hi my reply only works if its a ck carrier coil.

    Hi my reply only works if its a ck carrier coil.
  5. Replies
    22
    Views
    2,118

    electronic leak search followed by soap bubbles...

    electronic leak search followed by soap bubbles work for me 99% of the time. I make sure i am leak checking a dry evaporator coil not a wet one.
  6. If the evaportator is a carrier coil it is very...

    If the evaportator is a carrier coil it is very possible. Improper air changes, chemicals, blah blah blah if you hear that as an excuse thats a bunch of crap.
  7. Replies
    12
    Views
    2,125

    That contractor does not know what he is doing...

    That contractor does not know what he is doing other than changing out the txv until the problem finally is the txv.
  8. To whoever said they like to use cork tape. You...

    To whoever said they like to use cork tape. You obviously have never had to troubleshoot a txv after some idiot has wrapped it with cork tape. Takes like a half hour just to peel it off. It's not a...
  9. Replies
    14
    Views
    1,426

    Carrier has the tin coated coils.

    Carrier has the tin coated coils.
  10. Replies
    15
    Views
    3,720

    Thats fine if he does it himself. That way when...

    Thats fine if he does it himself. That way when the a/c crooks in his area sell him a new system at least he will know that it really is shot and that it is time to change.
  11. I would not waste my money on that company. If...

    I would not waste my money on that company. If they dont know what is wrong with equipment than maybe they should not be doing this type of work to begin with. Thats true about seer ratings but you...
  12. Replies
    17
    Views
    1,221

    he was the crook thats why he is as he stated...

    he was the crook thats why he is as he stated "previous home remodeling contractor". He says he knows the system and how it works. He means his system of how it worked. Not everyone is dishonest...
  13. Replies
    16
    Views
    1,480

    that sounds like a riser to help clean primary...

    that sounds like a riser to help clean primary drain.
  14. Just a question. Was this the lowest bid you...

    Just a question. Was this the lowest bid you got. Home owners thinking they did a smart thing and saved a couple hundred. Now you pay double. Just a question I could be off.
  15. Replies
    9
    Views
    717

    They should have used tubing insulation and some...

    They should have used tubing insulation and some tie straps to cover the txv.
  16. Replies
    155
    Views
    13,200

    "Varying professional opinions" ? From what I've...

    "Varying professional opinions" ? From what I've been reading everybody has the same opinion of your install.
  17. Replies
    155
    Views
    13,200

    Plexus is the installer of this furnace. Install...

    Plexus is the installer of this furnace. Install is not that great.
  18. Replies
    29
    Views
    2,031

    Oh I know this one. 4 potato peelers with...

    Oh I know this one. 4 potato peelers with missing teeth should do the trick.
  19. Replies
    5
    Views
    737

    how many people have died due to co

    how many people have died due to co
  20. Replies
    0
    Views
    646

    anybody know where I can get wiring diagram for...

    anybody know where I can get wiring diagram for armstrong furnaces?
  21. yes it will, and it is not the las.

    yes it will, and it is not the las.
  22. You need to sign up as a pro member and post this...

    You need to sign up as a pro member and post this question in the pro tech forum.



    [Edited by Mod2 on 11-24-2005 at 09:47 PM]
  23. Replies
    5
    Views
    2,237

    Hey thats over off of I-10. I always pass that...

    Hey thats over off of I-10. I always pass that club. Never been inside but heard good things about it.
  24. Replies
    10
    Views
    714

    ok there is a misunderstanding here. I am not the...

    ok there is a misunderstanding here. I am not the one suggesting anything to my friend. Only thing that stood out from the techs quote was when he wrote down that lineset was small for 12 seer but...
  25. Replies
    10
    Views
    714

    ok, so 7/8 is too small for 12 seer but perfect...

    ok, so 7/8 is too small for 12 seer but perfect for 14 seer that was what the tech wrote on estimate that is my question.
  26. Replies
    10
    Views
    714

    youre right but i just wanted to clarify the part...

    youre right but i just wanted to clarify the part in the invoice about seer rating and size of copper.
  27. Replies
    10
    Views
    714

    thats what i thought. I've always thought size of...

    thats what i thought. I've always thought size of copper was determined by ton and length of lineset but not by seer rating.
  28. Replies
    10
    Views
    714

    Hey I had a friend call me and she had a service...

    Hey I had a friend call me and she had a service tech give estimate on new system. Right now she has 2 and half ton system with 7/8 and 3/8 10 seer, tech quoted new 12 and 14 seer system but wrote on...
  29. Replies
    4
    Views
    968

    first off this was not my call, I was trying to...

    first off this was not my call, I was trying to help fellow coworker out. He was describing the problem over nextel. He said suction pressure was very low head pressure high suction line temp kept...
  30. Replies
    4
    Views
    861

    Wait just one second. Did you say the tech added...

    Wait just one second. Did you say the tech added 10.1 pounds of refrigerant or just an extra 4 ounces? The specs do show that a cond. unit has refrigerant for the first 15 feet but that is in cond...
  31. Replies
    13
    Views
    1,512

    38tra30 is a 2 and a half ton unit.

    38tra30 is a 2 and a half ton unit.
  32. Replies
    13
    Views
    1,512

    I think that system takes a 67 piston. Could be...

    I think that system takes a 67 piston. Could be wrong.
  33. Unit probably frozen because lack of airflow...

    Unit probably frozen because lack of airflow across evap coil due to bad run cap on indoor blower. Just my opinion.
  34. Have all of you forgotten that there is run cap...

    Have all of you forgotten that there is run cap on the indoor blower that could be the problem. Maybe no need to replace whole blower.
  35. Replies
    4
    Views
    1,032

    I've since changed out that unit. Put in a 4 ton...

    I've since changed out that unit. Put in a 4 ton Goodman.
  36. Replies
    3
    Views
    847

    Am I going crazy or is it true that you need a...

    Am I going crazy or is it true that you need a txv when using recip compressors? And start cap also.
  37. Replies
    4
    Views
    1,032

    Hi I have a model and serial. Looks like an...

    Hi I have a model and serial. Looks like an Airflow condenser could be wrong. aa1cj048-b serial is 3095ez0114
  38. Replies
    6
    Views
    1,706

    Thanks, thats what I thought it was. But here in...

    Thanks, thats what I thought it was. But here in town parts stores close very early and Sunday not open.
  39. Replies
    6
    Views
    1,706

    Hey, I was at a house today and unit is goodman...

    Hey, I was at a house today and unit is goodman gmp100-5 and during heat mode everything works up until flame comes on then once blower starts clicking sound turning off gas valve and blower keeps...
  40. There is not much info to give on dwnstrs. unit....

    There is not much info to give on dwnstrs. unit. Last Nov. Technician came out and c/o ignitors on both systems. Now a little over 2 months later both units having problems again. Could be that last...
  41. No, these filters are installed right at the r/a...

    No, these filters are installed right at the r/a grills as opposed to a media filter rack @furnace. Handled ignitor very carefully today. Last call in Nov. other tech replaced both ignitors. My...
  42. I was at a call today, 2 story house with 2...

    I was at a call today, 2 story house with 2 units. Both ignitors bad and both had been replaced November last year.
    Walk in house dwnstrs has mstr area filter and main hallway filter,both filthy...
  43. Replies
    65
    Views
    6,744

    you have got to be kidding.

    I can't believe that PJ Sullivan is now trying to blame immigrant workers for this crappy duct design. First let me tell you that behind that desk designing these systems is an old us of a good old...
Results 1 to 43 of 47
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event