  1. I got a new furnace. The Lennox was a tear-out...

    I got a new furnace. The Lennox was a tear-out that I used for 10 or 12 years. I think I got a decent return for the time I invested on the install.
    If I come up with a cheap blower I'll use it in...
  2. Main fan motor, Lennox Pulse Model #...

    Main fan motor,
    Lennox Pulse
    Model # GSR1404/5-80-7
    Serial # 5890E10710
    The unit is just about to old to mess with. If I can fix it cheap I will. Otherwise it's going for scrap.

    How about a...
  3. Replies
    71
    Views
    10,696

    Nope, it was 2 1/2 lb density spray foam over...

    Nope, it was 2 1/2 lb density spray foam over sheeting with a coating that had a stucco look. Sept or Oct issue 2006. I've been trying to find more info about the coating. Spray foam is differant...
  4. Replies
    71
    Views
    10,696

    Could you put me in contact with your friend. I...

    Could you put me in contact with your friend. I would like to pick his brain a little if he's willing. Could you ask him what the product is that he uses to coat foam on verticle applications. The...
  5. need a blower motor for a 80,000 btu Lennox pulse.

    I need a blower motor for a 80,000 btu Lennox pulse.
  6. Replies
    27
    Views
    8,338

    I am in immediate need of a 80,000 btu 90+...

    I am in immediate need of a 80,000 btu 90+ furnace. Upflow or down flow.
    I will buy a furnace today.
  7. Replies
    71
    Views
    10,696

    Does anybody have any experiance with homes spray...

    Does anybody have any experiance with homes spray foamed on the exterior? There was one in Fine Homes a while back. I've been looking into it but haven't found any info on what to coat the foam with....
  8. Replies
    27
    Views
    1,933

    Having the work inspected still gives you no...

    Having the work inspected still gives you no gaurantees of quality work. Most inspectors don't know how to size ductwork or systems. Nor do they care about quality. It's all about meeting minimum...
  9. Replies
    27
    Views
    1,933

    scroll down & read the "which one should I go...

    scroll down & read the "which one should I go with thread"
  10. Replies
    27
    Views
    1,933

    did you get any kind of itemized bids so you...

    did you get any kind of itemized bids so you could compare apart from the furnaces? Did you get referances & check out their work. Company size has nothing to do with quality.
  11. Replies
    3
    Views
    960

    Thanks

    Thanks
  12. Replies
    3
    Views
    960

    It's a 2.5 ton with a 1000 cfm blower

    It's a 2.5 ton with a 1000 cfm blower
  13. Replies
    3
    Views
    960

    I would much appreciate it if somebody could give...

    I would much appreciate it if somebody could give me a rough sq" start size for the return & supply of a 60,000 output BTU Yok direct vent furnace. Model# P2UDD10N05701C Serial# ELCMS15607. 2 1/2 ton...
  14. Replies
    71
    Views
    10,696

    My take is that as density increases insulation...

    My take is that as density increases insulation value & strength increases up to 3 lbs density. The contractor I work with advises me per application.
  15. Replies
    71
    Views
    10,696

    I prefer closed cell foam up to 3 lb density. It...

    I prefer closed cell foam up to 3 lb density. It is the only foam that I know of that adds structural integrity.
  16. Replies
    12
    Views
    779

    I am planning to put it behind the refridgerator....

    I am planning to put it behind the refridgerator. Planning on setting it at 75 for a start. There will be 1 person who will know where it's at for further adjustment if needed.
  17. Replies
    12
    Views
    779

    What the sam hxxx are you typing about? Please...

    What the sam hxxx are you typing about? Please explain your question.
    I assume by saying anexhaust fan may kill the occupants, You are speaking of sucking enough air out of the room so the...
  18. Replies
    12
    Views
    779

    I dont have 1000 posts but I'll try. Install a...

    I dont have 1000 posts but I'll try.

    Install a Thermostat in line with the exhaust fan. Set it for 80 to 90 deg F. You can fine tune it later.

    I recomend Fan Tech for this usage. Quiet...
  19. Replies
    12
    Views
    779

    Thought about turning it down but somebodies...

    Thought about turning it down but somebodies going to do it. I like doing new things. I'm going to learn something I never thought I would need to know. Might even come up again some day. Never know....
  20. Replies
    12
    Views
    779

    New guys aren't allowed to be a smart ass to...

    New guys aren't allowed to be a smart ass to those with more than 1,000 posts! It isn't in the site rules but I'm backing it.

    My first question & instead of an intelligent thought out answer I...
  21. Replies
    12
    Views
    779

    This is residential. Not exactly my level of...

    This is residential. Not exactly my level of residential. 2 refridgerators, 2 pantries, I didn't catch the brand, all stainless, larger than average, top half fridge, bottom half freezer. They do...
  22. Replies
    12
    Views
    779

    I need to install an exhaust fan for a...

    I need to install an exhaust fan for a refridgerator. I am planning to use 6" pipe with a booster fan installed. I need a current sensing relay to start the fan with the fridge. My supply houses...