08-18-2008, 06:14 AM
Thread: Lennox xp 14 heat pump
by S_Helton- Replies
- 5
- Views
- 1,378
Could be thermostat location. Also, it could be...
Could be thermostat location. Also, it could be due to lack of insulation in your house.
-
08-07-2008, 06:15 AM
Thread: Low (too low?) Fan Speed with Comfort R
by S_Helton- Replies
- 4
- Views
- 556
Unless things have changed with Trane in the past...
Unless things have changed with Trane in the past 3 years, the blower runs at 50% of full air flow when the fan is set to on. Also the first 10 mins should be at 50% as well. Unless you are using...
-
08-07-2008, 06:01 AM
Thread: Split Geo Thermal units
by S_Helton- Replies
- 2
- Views
- 460
It can as long as the blower capacity matches...
It can as long as the blower capacity matches what the Geothermal unit requires. If the unit is rated using a variable speed blower, make sure the furnace has one.
-
08-07-2008, 05:58 AM
- Replies
- 8
- Views
- 697
No. You should contact an HVAC specialist in your...
No. You should contact an HVAC specialist in your area and let them tell you if they can shorten the piping. This is not a DIY site.
-
08-06-2008, 06:30 AM
Thread: Is Aeroseal still in business
by S_Helton- Replies
- 7
- Views
- 713
Call the factory and find a different vendor. The...
Call the factory and find a different vendor. The website may not have been updated in a while.
-
08-06-2008, 06:24 AM
Thread: Heat pump advice
by S_Helton- Replies
- 6
- Views
- 587
I would say dual fuel would be the way to go.
I would say dual fuel would be the way to go.
-
08-03-2008, 09:29 AM
Thread: Cooling my garage
by S_Helton- Replies
- 6
- Views
- 755
You would still want a heat loss/heat gain done...
You would still want a heat loss/heat gain done on the garage. If you put too big of a unit in, it can lead to short cycling. Ductless mini splits are the way to go. The air handler is mounted on the...
-
08-03-2008, 08:47 AM
Thread: Balancing AC
by S_Helton- Replies
- 2
- Views
- 342
I would suggest a zoning system. If there is...
I would suggest a zoning system. If there is access to the attic above both rooms, or at least 1 wall accessible from the attic in both rooms, then you could have a thermostat in both rooms....
-
08-03-2008, 08:41 AM
- Replies
- 28
- Views
- 3,706
It is possible for a coil to leak within 4 years....
It is possible for a coil to leak within 4 years. The model number and manufacturer name would help. Some manufacturers have a 10 yr part warranty, which would allow you to get other labor...
-
08-02-2008, 06:20 PM
Thread: ac recommendation
by S_Helton- Replies
- 9
- Views
- 704
You need to edit your post. Discussing prices are...
You need to edit your post. Discussing prices are not allowed. Read the rules.
-
08-02-2008, 05:58 PM
Thread: ac recommendation
by S_Helton- Replies
- 9
- Views
- 704
What Daltex and Beenthere said.
What Daltex and Beenthere said.
-
08-02-2008, 05:33 PM
Thread: Electronic Dampers on Return Air?
by S_Helton- Replies
- 24
- Views
- 1,457
Yes, but again I say, if his lifestyle changes...
Yes, but again I say, if his lifestyle changes and he wants both floors occupied, he will be sorry.
-
08-02-2008, 05:31 PM
Thread: capacitor sparking
by S_Helton- Replies
- 21
- Views
- 1,065
Loose connections would be my first thought....
Loose connections would be my first thought. Either the spade connection, or where the spade connection is crimped on the wire.
-
08-02-2008, 05:17 PM
Thread: Electronic Dampers on Return Air?
by S_Helton- Replies
- 24
- Views
- 1,457
Dash- I agree, you shouldn't plan for future...
Dash- I agree, you shouldn't plan for future owners. But I still stand by my opinion that it is not smart to replace 2 systems with 1 system. Then zone it, and hope that you never want the whole...
-
08-02-2008, 05:05 PM
Thread: Electronic Dampers on Return Air?
by S_Helton- Replies
- 24
- Views
- 1,457
Yes, he does. He is also considering doing away...
Yes, he does. He is also considering doing away with 2 systems, and going back with just 1 system with zoning.
I was just making points of why I would not recommend doing that.:cool: -
08-02-2008, 04:55 PM
Thread: Electronic Dampers on Return Air?
by S_Helton- Replies
- 24
- Views
- 1,457
So, when he sells the house and the new owner has...
So, when he sells the house and the new owner has a different lifestyle? Or if his life style changes? He can control the house the same way with 2 systems.
-
08-02-2008, 02:34 PM
Thread: WD-40 Is Used For?
by S_Helton- Replies
- 13
- Views
- 966
Agreed!!
Agreed!!
-
08-02-2008, 02:31 PM
Thread: Electronic Dampers on Return Air?
by S_Helton- Replies
- 24
- Views
- 1,457
One negative that I can think of by going from 2...
One negative that I can think of by going from 2 systems to 1 system with a damper system, is breakdowns. If you have 2 systems and one has a problem, then at least you have 1 working system until...
-
08-02-2008, 02:17 PM
- Replies
- 1
- Views
- 456
First, I would make sure that they provide a...
First, I would make sure that they provide a Manual J heat loss/heat gain, and show the capacities of the chosen equipment.
I can only say what I've seen in my area for the rest. I would prefer my... -
08-02-2008, 01:53 PM
Thread: Why does Goodman get a bad rap?
by S_Helton- Replies
- 111
- Views
- 6,841
Hehe....too true:cool:
Hehe....too true:cool:
-
08-02-2008, 01:42 PM
Thread: Power factor converter
by S_Helton- Replies
- 17
- Views
- 892
This is a link to Reducing Power Factor Cost. It...
This is a link to Reducing Power Factor Cost. It is a US Dept of Energy document. It does a good job explaining what the Power Factor is. Also, how "real" power, "apparent" power and "reactive" power...
-
08-02-2008, 01:31 PM
Thread: Where should returns go?
by S_Helton- Replies
- 49
- Views
- 2,196
Cost for many consumers would be the deciding...
Cost for many consumers would be the deciding factor. Cost is almost always a factor. Even when you educate the consumer, they still look at the bottom line. In my area, metal duct has become rare....
-
08-02-2008, 01:08 PM
- Replies
- 7
- Views
- 585
Did Sears show you the heat loss? That would be...
Did Sears show you the heat loss? That would be the first question. Also, the ductwork will affect it as well. Is it insulated? Is your floor insulated? These things will have a direct bearing on the...
-
08-02-2008, 01:04 PM
Thread: Do you buy your work tools or not?
by S_Helton- Replies
- 31
- Views
- 1,401
This is what matters when it is your...
This is what matters when it is your business...agreed:D
-
08-02-2008, 12:59 PM
Thread: Where should returns go?
by S_Helton- Replies
- 49
- Views
- 2,196
I think the assumption was if a 1" space under...
I think the assumption was if a 1" space under the door is enough, do you need more? I don't think that more is always better, unless you are talking about the velocity of the air. A larger return...
Results 1 to 25 of 53