  1. Replies
    8
    Views
    164

    suction line is 80 degrees.

    suction line is 80 degrees.
  2. Replies
    8
    Views
    164

    I figured 400cfm per ton of cooling and used a...

    I figured 400cfm per ton of cooling and used a sliding duct calc to lay it out. i may not be the sharpest service man, but I have fabed and installed alot of duct.
    so, here is where I am at now...
  3. Replies
    8
    Views
    164

    Poolde, the duct is all new and is sized...

    Poolde, the duct is all new and is sized properly.
  4. Replies
    8
    Views
    164

    No, problem was that I was using 404 instead of...

    No, problem was that I was using 404 instead of 410 on PT chart. Screwed up columns while scrolling down. So I now have, 90 ambient, have 350 head, 96 degree liquid line which makes 10 degree sub...
  5. Replies
    8
    Views
    164

    High sub cooling question

    I have a Rheem 3 ton split cooling unit.
    85 degrees outdoor temp
    133 suction pres
    335 high pressure
    12 degrees across evap
    And 26 degrees of sub cooling.

    Air flow is good, what am I not...
  6. Replies
    13
    Views
    556

    I talked to a tech at Cornelious and the error...

    I talked to a tech at Cornelious and the error code 5 is the same on the 530 as it is on the bigger units. Which makes sense, and is backs up what I thought the problem might be. A water feed issue.
  7. Replies
    13
    Views
    556

    http://www.cornelius.com/about-us/heritage.aspx ...

    http://www.cornelius.com/about-us/heritage.aspx

    I guess everyone looked like a mobster in 1930.
  8. Replies
    13
    Views
    556

    Terry, I know, that has me puzzled. I am going to...

    Terry, I know, that has me puzzled. I am going to try something tomorrow and will post the results. But the red error light is definitely blinking five times.
  9. Replies
    13
    Views
    556

    Wait, I believe I might have it. To be...

    Wait, I believe I might have it. To be continued.....
  10. Replies
    13
    Views
    556

    2004. I've worked on alot older units. Sadly.

    2004. I've worked on alot older units. Sadly.
  11. Replies
    13
    Views
    556

    Cornelious XAC530 ice mach problem

    The unit had red error light flashing a 5 flash code. I don't find a 5 in the error codes for a 530. Unless I am reading it wrong.
    The unit when started after cycling on/off switch, compressor...
  12. Wish I had this forum along time ago!!

    Great to be able to ask a question to so many knowledgeable people at once.
  13. Replies
    11
    Views
    2,702

    I will take a closer look at things today. Thanks...

    I will take a closer look at things today. Thanks for all the help.
  14. Replies
    11
    Views
    2,702

    http://www.tecumseh.com/en/corporate/product-searc...

    http://www.tecumseh.com/en/corporate/product-search?application=LBP+-+Low+Back+Pressure&refrigerant=R12&voltage=208-230V+~+60Hz&capacity_min=0&capacity_max=44000&producttype=Condensing+Units
  15. Replies
    11
    Views
    2,702

    I don't believe it was ever a freezer, maybe...

    I don't believe it was ever a freezer, maybe someone purchased the wrong condensing unit. I can't go into the history of work that has been done at this place, but it's very sketchy, to say the...
  16. Replies
    11
    Views
    2,702

    Is it common to have a low back pressure...

    Is it common to have a low back pressure condenser on a 40 degree walk in cooler?
  17. Replies
    11
    Views
    2,702

    R12 Low pressure on walk in cooler

    Have a walk in cooler where I work that had a frozen evap. After looking into it, I was surprised to see a low back pressure condenser on this walk in. Is this normal? The walk in is used in a...
Results 1 to 17 of 17