    i suggest every tech in the feild has on his...

    i suggest every tech in the feild has on his truck the copeland bible chocked full of everything including oil pumps, net oil pressures and troubleshooting for those who don't have i seen some nice...
  2. Thread: HELP

    by jumperwire
    Replies
    7
    Views
    840

    you're walk-in freezer sounds to be running at a...

    you're walk-in freezer sounds to be running at a perfect temp for a walk-in cooler LOL no need to convert. i suggest remove the ice or find the leak. Sounds like there's going to be a all you can eat...
  3. Replies
    11
    Views
    1,125

    oh see if mgnt. might spring for some water...

    oh see if mgnt. might spring for some water filters for in line with the water or water softer
  4. Replies
    11
    Views
    1,125

    sounds to me you have a machine that was...

    sounds to me you have a machine that was neglected and mgnt. dos'nt care too much either all i can suggest is to clean with ice machine cleaner on a 60 day bases if your enviro conditions are that...
  5. Replies
    9
    Views
    848

    i dont think you have a built unit with hot shot...

    i dont think you have a built unit with hot shot i dont think anyone is using hotshot as a factory charge seems it was put in as a replacement for r-12 or 134a i hear on low temp refrig S.H should be...
  6. Replies
    11
    Views
    1,125

    Realistically theres no way to control mold only...

    Realistically theres no way to control mold only way to control mold is to control moisture since we are talking ice machine there goes that thought there are over a 100,000 species of mold and...
  7. Jimmy cracked corn and I dont care. Now what kind...

    Jimmy cracked corn and I dont care. Now what kind of attitude is that?
  8. Replies
    13
    Views
    1,270

    super heat is taken at the outlet of the evap....

    super heat is taken at the outlet of the evap. temp on outlet line and pressures converted to temp. no service port at evap pump it down and install one. another theory superheat is to protect the...
  9. i hope noboby is pumping down in a vac like i...

    i hope noboby is pumping down in a vac like i read in the one thread all pump downs cut-out 0 cut-in 10
  10. i like zoom spout oil as a thread sealant leak...

    i like zoom spout oil as a thread sealant leak lock i have found in the screens of the txv like to migrate if gets in the system be careful when using
  11. wow someone sounds experienced in artifical mind...

    wow someone sounds experienced in artifical mind altering
    thats scary thank god for random drug testing and the weeding out process
  12. Replies
    17
    Views
    1,437

    it took me and my helper 14 hours we sat the new...

    it took me and my helper 14 hours we sat the new comp in place i told him to install the oil pressure contol awhile i'll be right back 5 mins later i had oil from here to china and guess where i sat...
  13. sorry dowadudda i stand corrected

    sorry dowadudda i stand corrected
  14. LOL dowadda or list in the asian times

    LOL dowadda or list in the asian times
  15. Replies
    15
    Views
    1,093

    i like to appologise my caps were stuck un...

    i like to appologise my caps were stuck un beknownst to me i was not screaming thank you mr. flanders
  16. Replies
    14
    Views
    1,794

    to lower superheat means that more refrig is...

    to lower superheat means that more refrig is needed in the evap.

    with more refrigerant the point at which all vapor is boiled off moves closer to the coil outlet. in other words, more of the evap...
  17. seriously call some refrig companies if they are...

    seriously call some refrig companies if they are unused explain your sit. i bet you will find that buyer maybe find a refrig. co. doing rest.
  18. cut out the coils it will fetch you more then...

    cut out the coils it will fetch you more then ebay clean copper how much a pound now?
  19. Replies
    15
    Views
    1,134

    correct naming icemeister thank you you're cool...

    correct naming icemeister thank you you're cool with me i'll get better at my pecking see ya around hey theres a great 1939 refrig manual on ebay that should be fun to read
  20. Replies
    15
    Views
    1,134

    iceman you're killing me LOL i'm going back to...

    iceman you're killing me LOL i'm going back to listing used refrig manuals on ebay
  21. Replies
    15
    Views
    1,134

    thank you ICEMAN lol

    thank you ICEMAN lol
  22. Replies
    15
    Views
    1,134

    oopppsss sorry about the caps busing pecking here

    oopppsss sorry about the caps busing pecking here
  23. Replies
    15
    Views
    1,134

    THE WAY I SEE THE QUESTION WE ARE TALKING T'STAT...

    THE WAY I SEE THE QUESTION WE ARE TALKING T'STAT OPERATING A SOLENOID. OPEN OR CLOSED DEPENDING ON TEMP I SEEN RACKED SYSTEMS WITH FANS AND GRAVITY COFFIN CASES. ARE WE TALKING FORCED AIR. THEN THE...
  24. Replies
    15
    Views
    1,134

    I'M TALKING FORCED AIR ON COMMERICIAL...

    I'M TALKING FORCED AIR ON COMMERICIAL REFRIGERATION EVAPORATORS IN THEORY. WHAT YOU APPROX. SHOULD HAVE COMPARED TO WHAT YOU ACTUALLY HAVE. THESE ARE JUST STANDARD INDUSTRY FIGURES BALLPARK LIKE...
  25. Replies
    15
    Views
    1,134

    IF I WAS TO PUT THE T'STAT AT THE RETURN OF THE...

    IF I WAS TO PUT THE T'STAT AT THE RETURN OF THE COIL AND READ 40 DEGREES THAT TELLS ME I SHOULD HAVE A 20 DEGREE COIL AND A 30 DEGREE SUPPLY WITH A TD OF 20 R-22 SHOULD HAVE AROUND 43 # SUCTION AT...