12-04-2005, 02:44 AM
Thread: Consolidated Industries furnance
by page- Replies
- 6
- Views
- 677
I check the volts from the MV and the PV and the...
I check the volts from the MV and the PV and the problem was from another bad smart valve that I installed I took it of again and bench test it and one of the valves was bad in that new valve. I was...
-
12-03-2005, 06:08 PM
Thread: Consolidated Industries furnance
by page- Replies
- 6
- Views
- 677
I checked the control board,all of the rollout...
I checked the control board,all of the rollout switch and the sensors. The gas valve was not giving off the gas to the rail. I put a new valve(honeywell) on the unit and the valve is still not...
-
07-17-2005, 11:58 PM
Thread: EMI Heat pump
by page- Replies
- 1
- Views
- 873
How you all been doing. I have been working here...
How you all been doing. I have been working here in Louisiana on these A/C's in these attics from 7:00 a.m. to 8:00-9:00p.m. at night, that is why I have not been online. I am repairing a EMI unit...
-
06-03-2005, 09:56 PM
Thread: Checking a circuit board on a goodman
by page- Replies
- 4
- Views
- 789
I changed that board to day and that took care of...
I changed that board to day and that took care of that.
-
05-31-2005, 10:42 PM
Thread: Checking a circuit board on a goodman
by page- Replies
- 4
- Views
- 789
From my checking the relay on the circuit board...
From my checking the relay on the circuit board is bad. Some time the unit kick on some time it don't, it does good at night but in the day time that relay on that board sticks. The unit is just two...
-
05-25-2005, 05:49 AM
Thread: beer cooler with r134a
by page- Replies
- 3
- Views
- 844
I have been running around like crazy in those...
I have been running around like crazy in those attics. I will let you know by tonight.
-
05-24-2005, 11:00 PM
Thread: beer cooler with r134a
by page- Replies
- 3
- Views
- 844
What should the loe and high pressure be around...
What should the loe and high pressure be around when you are charging the unit with a hot box that uses r134a.
-
02-21-2005, 10:21 PM
Thread: Quatron unit
by page- Replies
- 9
- Views
- 642
thank you,I will check goodman out tomorrow. And...
thank you,I will check goodman out tomorrow. And by the way this is my parent house they been in it one year now.
-
02-20-2005, 05:09 PM
Thread: Quatron unit
by page- Replies
- 9
- Views
- 642
The unit is ten years old. and the computer board...
The unit is ten years old. and the computer board is not cutting the unit off. Unless you cut the unit off from cool to off on the thermostat. And the heat is not coming on at all. The blower relay...
-
08-31-2004, 03:32 PM
Thread: Trane 3 ton that is six years old
by page- Replies
- 14
- Views
- 1,866
I changed the evaporator and I used my electronic...
I changed the evaporator and I used my electronic leak detector to make shore that the new one was not leaking. But what is a good why to check the condensor for leak because there are a lot of trees...