Search:

Type: Posts; User: tbk

Page 1 of 6 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    13
    Views
    1,606

    He lives down here in SC now, yes a remarkable...

    He lives down here in SC now, yes a remarkable man! One of very few I call a true friend!
  2. Replies
    11
    Views
    925

    Which is why this section should be in the PRO...

    Which is why this section should be in the PRO SECTION which has been stated numerous times!
  3. Replies
    13
    Views
    1,606

    I by no means am an expert or have any experience...

    I by no means am an expert or have any experience with them just putting out there for comparsion / options
  4. Replies
    13
    Views
    1,606

    Ok here is the link to his web site, can tell you...

    Ok here is the link to his web site, can tell you the cost is a FRACTION of those others posted. And know he is looking for installers/ reps

    coolfreeinc.com
  5. Replies
    13
    Views
    1,606

    Wow! Didnt know, all I know is he said he has...

    Wow! Didnt know, all I know is he said he has had it patented for 20 PLUS years! Ill be sure to send him those links!
  6. Replies
    13
    Views
    1,606

    Cooler Guys New Old Product

    Have A friend of mine getting ready to Re-ramp up a product he designed and patented and trade maked years ago! Pretty cool setup!

    Think he calls it COOL FREE! basiclly for colder climates, it...
  7. Replies
    53
    Views
    12,839

    tar stuff = previouslly exploded soda cans ...

    tar stuff = previouslly exploded soda cans clean it
  8. Thread: Mani Im question

    by tbk
    Replies
    35
    Views
    2,140

    bin switch or something on evap plate catching...

    bin switch or something on evap plate catching ice and not allowing it to drop, dirty/ nick or snag
  9. Thread: Cooler Panels?

    by tbk
    Replies
    7
    Views
    679

    thanks guys, passed on info

    thanks guys, passed on info
  10. Thread: Cooler Panels?

    by tbk
    Replies
    7
    Views
    679

    Warm Beer, i gave this guy ur email addy that...

    Warm Beer, i gave this guy ur email addy that you have listed, maybe you guys can do something!
  11. Thread: Cooler Panels?

    by tbk
    Replies
    7
    Views
    679

    thanks, but has to be new for his bid

    thanks, but has to be new for his bid
  12. Thread: Cooler Panels?

    by tbk
    Replies
    7
    Views
    679

    Cooler Panels?

    Hey guys need some help. Got a good friend in the bus and he needs to put toghether a bid for a 20,000 sg ft cooler. (200 x 100 I think).
    Problem is he doesnt think the local suply houses are...
  13. Replies
    18
    Views
    1,502

    can we assume it is running nonstop 24/7 the...

    can we assume it is running nonstop 24/7 the thermostat for that unit looks for a COIL temp of 28 degrees, maybe a bit overcharged. or undercharged freezing at the probe shutting unit off early????
  14. Replies
    7
    Views
    1,453

    this thing is supposedly less than a year old,...

    this thing is supposedly less than a year old, and yes its a daily use thing, they start it in the morning and cut off at night, the 2-4 psi thing is what I was looking for (I THINK). havent been...
  15. Replies
    7
    Views
    1,453

    saw that ICE, but this one doesnt have the cond...

    saw that ICE, but this one doesnt have the cond as part of the unit, not sure what kinda pressures to run or should be running at!
  16. Replies
    7
    Views
    1,453

    Sushi Table helppppp

    never seen an animal like these!

    OHO Products Co. LTD
    MH1500 NM-L

    appears to only be a flat coil incased in a stainless box, no evap fan, no thermostat, and a small condensor, no pressure...
  17. Replies
    18
    Views
    2,600

    my bad SORRY

    my bad SORRY
  18. Replies
    18
    Views
    2,600

    and be pepared to recharge it now that you put...

    and be pepared to recharge it now that you put your gages on it, cant remember the last time had to use gages on a mani to fix the problem
  19. Thread: TXV question

    by tbk
    Replies
    3
    Views
    473

    Doesnt have the SQB in it now, totally diff look,...

    Doesnt have the SQB in it now, totally diff look, so I am guessing no screen and Im prob gonna have to replace this one!
  20. Thread: TXV question

    by tbk
    Replies
    3
    Views
    473

    TXV question

    Iknow that the flare mounting type have the screen in the inlet, But what about the soldier mounting type, is there a screen somewhere, got one that is frosting /freezing starting at the distrib...
  21. Replies
    15
    Views
    1,174

    there was a service bulletin about water probs on...

    there was a service bulletin about water probs on a machine and it was something about a screw that was to long on the bottom of the evap, but dont know what model u have, I think it was on q or s...
  22. Replies
    7
    Views
    1,134

    if its 2 yrs old that evap is under warranty,...

    if its 2 yrs old that evap is under warranty, Make em give it to you!!!!!!
  23. Replies
    6
    Views
    851

    thanks, I coat it with a clear coat or buy...

    thanks, I coat it with a clear coat or buy another!
  24. Replies
    6
    Views
    851

    Fiberglass Ext ladders

    anyone have an issue with thier ladders that sit on top of there vans all the time. Mine is about 4 years old and every time I use it I get fiberglass all over my arms, just drives me nuts!!!!!!!!
  25. Replies
    40
    Views
    2,466

    PHM it is supposed to fill on start up and then...

    PHM it is supposed to fill on start up and then once more after the level drops below the probe during each cycle, ill get the book out and see what else it says.

    ok pg 68 of handbook talks about...
  26. Replies
    19
    Views
    3,671

    Had one about 2 years ago did Identical thing....

    Had one about 2 years ago did Identical thing. replace the probe per Mani, 2 days later same. Probe again per mani, 3 days later same thing. New board per ME havent had a prob since!!
  27. Replies
    42
    Views
    10,512

    from fear of looking stupid! What is coss...

    from fear of looking stupid! What is coss training and where !
  28. Thread: One or those days

    by tbk
    Replies
    15
    Views
    1,582

    Exactly why they can get someone else to work on...

    Exactly why they can get someone else to work on there crap, happened to me three times before I said NO MORE. Even tried the "MARKED UP" price thing to negotiate with them, didnt work, got cheated! ...
  29. Replies
    13
    Views
    990

    Dont know where the idea of this being a r12 comp...

    Dont know where the idea of this being a r12 comp came from but it is NOT.
    It was original r12 system but the condensing unit/compressor had been changed out to r-22, verified this the very first...
  30. Replies
    13
    Views
    990

    unknow why coverted to 22, thats just whats there...

    unknow why coverted to 22, thats just whats there now, wasnt a blackish goo, more like oxidation particles from brazing.

    Pumped down and removed the screens again, NO contamination, screens still...
  31. Replies
    13
    Views
    990

    All press align to PT chart until the valves...

    All press align to PT chart until the valves freeze, unit has been there for some time, checked the sizing originally and all matched up, dont see where you are going with this.
  32. Replies
    13
    Views
    990

    Did not pull into a vacumm, think it was set at...

    Did not pull into a vacumm, think it was set at 10psi. have, did, always use a micron gauge and yes have broke with nitro, and yes takes hours to pull down!

    This first time I repaired and pulled...
  33. Replies
    13
    Views
    990

    W/I Clr Retro Guru's needed

    Geesh ! I wish they would put this forum in the pro section! But anyway

    Been fighting this W/i for awhile. Dont have Mod #'s but dont believe it is relavent at this time.

    14 door convience...
  34. Replies
    14
    Views
    1,556

    alos check the power hear on the txv, break or a...

    alos check the power hear on the txv, break or a rub thru on the small tube going to the bulb will cause the same thing!
  35. Replies
    11
    Views
    836

    Well couldnt get a 134 unit in less than 2 days,...

    Well couldnt get a 134 unit in less than 2 days, so had to go 404a and change the txv ect... but thanks ever so much for those of you who chimed in, I think I learned more about condensing units on...
  36. Replies
    11
    Views
    836

    well thanks for the help guys, but got forced...

    well thanks for the help guys, but got forced into something different, ill type more in the morn, to freaking tired!!!!!!!!!!!! SNOOOOZZZEEEE!!!!!
  37. Replies
    11
    Views
    836

    Let me expond abit. there is a 3 foot...

    Let me expond abit.

    there is a 3 foot cleareance from the top of the cooler box to the drop in ceiling. unit will sit on top of the box as it has for 20 plus years!

    #2 , not saying it will get...
  38. Replies
    11
    Views
    836

    Ice , you wouldnt be concerned about the diff in...

    Ice , you wouldnt be concerned about the diff in amb ratings and the btu's??????? Educate me!!!!!!!!!
  39. Replies
    11
    Views
    836

    W/I Clr Retro Guru's needed

    ok here is the story need you guys help!
    Have a W/I 7.5 x 7.5 x 82 in tall, org R12 system, Was water cooled but sometime coverted to air cooled.

    Cope comp #KWG-0075-tac ( 3 Ph)
    Evap Bohn...
  40. Thread: Hoshi alarm help!

    by tbk
    Replies
    6
    Views
    992

    went to check it out, 3 beep (60 min freeze)...

    went to check it out, 3 beep (60 min freeze) checked water valve for leakage, float for sticking, HGV not bypassing, and couldnt get the thing to break again, watch about 4 cycles and all were at...
  41. Thread: Hoshi alarm help!

    by tbk
    Replies
    6
    Views
    992

    Thank you! Tried to email hoshi and get one of...

    Thank you! Tried to email hoshi and get one of these books but it wont go thru!
  42. Thread: Hoshi alarm help!

    by tbk
    Replies
    6
    Views
    992

    Thanks ICE, but you double linked the SB , no...

    Thanks ICE, but you double linked the SB , no manual!!
  43. Thread: Hoshi alarm help!

    by tbk
    Replies
    6
    Views
    992

    Hoshi alarm help!

    got a call last night, havent been there yet! Alarm going off on hoshi, dont know model # its only about 2 years old around a 500lb machine, just cleaned it a week ago and didnt pay attention to...
  44. Replies
    6
    Views
    745

    Well here is a thought........... Anyone ever...

    Well here is a thought........... Anyone ever Report them !!!!!!!!!!
  45. Replies
    23
    Views
    1,939

    NP I understood

    NP I understood
  46. Replies
    23
    Views
    1,939

    Think he said he is running at ZERO so that would...

    Think he said he is running at ZERO so that would be close, maybe Ill stop in and check it for him! Thanks
  47. Replies
    23
    Views
    1,939

    unknown, just got a call asking about it!

    unknown, just got a call asking about it!
  48. Replies
    23
    Views
    1,939

    frost on freezer compressor

    is it possible for frost to work all the way to comp it all SH setting are correct?
    Very short lines, maybe 3 feet long.
    Walkin freezer.
  49. Replies
    25
    Views
    5,546

    Check the grip plates for loose, they are not...

    Check the grip plates for loose, they are not supposed to move at all!
    common failure and same problems on many of these 170's.
    Oh and the new plate only cost $600.00 lol
  50. Replies
    11
    Views
    1,188

    last 2 i got from parts house were blue, maybe...

    last 2 i got from parts house were blue, maybe real old stock idk
Results 1 to 50 of 293
Page 1 of 6 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event