    Data Sharing Between Two Jace Stations

    Hello, I have a customer that does not want a supervisor on site for a few different reasons.

    I need the best way to have one access point so they do not have to log into two separate stations. I...
  2. Replies
    16
    Views
    466

    I'm with you on this. If its all two way with no...

    I'm with you on this. If its all two way with no bypass it should basically dead head the pump. If the suction is getting low enough to open fill you got some other issues. It almost sounds like its...
  3. Yeah I may try the oil swap. It just seems like a...

    Yeah I may try the oil swap. It just seems like a waste because during the tear down at the manufacturers they had to use compressed air to blow out the orifice and that little pill filter like the...
  4. Just a simple R22 20 ton split. Cooling only. Yes...

    Just a simple R22 20 ton split. Cooling only. Yes it's a liquid core drier no suction. No acid in the system. I may get the oil tested to see what it is if they will actually tell what the...
  5. Anyway To Tell If "Stop Leak" Has Been Added To System?

    Long story short 06E tripping off on oil failure. Compressor doing odd things and I mean odd. I condemn compressor due to issues and noises. Pull it out swap in new away we go. Field strip unit to...
  6. Replies
    5
    Views
    407

    http://www.emersonclimate.com/en-us/Resources/Docu...

    http://www.emersonclimate.com/en-us/Resources/Documents/Frozen-Coil-Update-8-28-14.pdf

    As mentioned check with tech support from your manufacturer. Different companies doing different repairs from...
  7. As already mentioned that is a waste of money it...

    As already mentioned that is a waste of money it is not a PM. This is what happens when sleazy companies try to use a business technique to "lock" customers into agreements hoping to get repair work....
  8. Replies
    0
    Views
    122

    Lonspec Question

    I have an old Lonspec site that is I believe 5.0.. They just have a few RTU on the system (W7750). One started acting weird and not taking set-points correctly, zone sensor drifting around etc. I...
  9. Replies
    2
    Views
    276

    I think I kind of figured it out. The limits look...

    I think I kind of figured it out. The limits look good and I figured if it was those it would mess up the active whether it was enabled or disabled on the thumb wheel. My CSLL 70 HSHL 76 HSLL 68 CSHL...
  10. Replies
    2
    Views
    276

    3.8 AX Comm 4 VAV Question

    Hello All.
    I am just starting to get my feet wet with AX and I have a quick question. When I set my thumb wheel enable to on I have an issue. The active heat/cool changes and they switch from set...
  11. Replies
    2
    Views
    268

    Cool! Thanks for the help.

    Cool! Thanks for the help.
  12. Replies
    2
    Views
    268

    Niagara AX Comm 4 Driver Question

    I see where the Comm 4 driver is listed for the Intellipak RTU but can it also be used on the Intellipak CSC? Both are comm 4. Thanks!
  13. Thanks guys I think that you hit the nail on the...

    Thanks guys I think that you hit the nail on the head. They are writing way too much to the boards. They basically exposed every point available, stuff that does not need to be messed with. Thanks...
  14. Trane Comm 4 Board Failures On Tridium Systems

    Has anyone else noticed a fair share more of comm 4 failures on PIU/VAV brought into a JACE. I have done Trane controls for a long time and it seems if I did see a failure of a UCM it was a total bit...
  15. Replies
    3
    Views
    674

    Very easy, done several, very good response from...

    Very easy, done several, very good response from customers. Usually done as part of LEED green building certifications. Give engineers three levels of set points to unload facilities as you get...
  16. Replies
    9
    Views
    900

    So when you say you tested the switch you put the...

    So when you say you tested the switch you put the unit in test mode and kept the mag (and meter clamped across terminals on ohms) on it while you started just the exhaust fan and took readings every...
  17. Replies
    15
    Views
    6,408

    Hopefully you are not in the previously mentioned...

    Hopefully you are not in the previously mentioned area because if you are I can almost guarantee that they will tell you to pound sand. Hopefully if you are you have friends in another jurisdiction...
  18. Replies
    9
    Views
    900

    Like mentioned the DP switch or usually I just...

    Like mentioned the DP switch or usually I just bump the minimum HZ up on the VFD.
  19. Replies
    11
    Views
    1,642

    Second Hugh Cole. If he is still doing it you...

    Second Hugh Cole. If he is still doing it you won't find a more knowledgeable teacher and all around great guy. When I took the test the difference between restricted and non restricted was four...
  20. Replies
    15
    Views
    3,238

    I've seen some codes that wanted a motorized...

    I've seen some codes that wanted a motorized damper for smoke/fire shut down instead a RTU mounted chimney with barometric relief and fixed % intake.
  21. In my state you are allowed as a company owner to...

    In my state you are allowed as a company owner to be exempt from your policy and you pay the base amount to "have" a workers comp policy. This doesn't cover you but it allows your COI to show you...
  22. Replies
    3
    Views
    658

    That does help. I think I can program that....

    That does help. I think I can program that. Thanks!!!
  23. Replies
    3
    Views
    658

    Trane TGP Question

    I have a really simple question I am sure for someone who is very adept to TGP. I'm not, I cookbook and can make changes but not a from scratch pro. I have a small 20 Ton CV AHU with OA damper, CO2,...
  24. Replies
    5
    Views
    720

    Oil Additive For Voyagers Headers Now?

    I just had another restricted header on a Voyager and was going to replace the header with a TXV kit and now I m being told that this 1.5 year old (410A) RTU has an additive that can be injected...
  25. Replies
    0
    Views
    526

    Help Stop CISPA/CSA

    Unless you love government digging into every part of your computer habits, this bill needs to DIE. In typical big brother fashion they didn't get their first draft thru, but that isn't stopping them...
Results 1 to 25 of 216
Page 1 of 9 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event