Search:

Type: Posts; User: trgams

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    21
    Views
    2,146

    I'm So CONFUSED!!!!!!!!!!!!!!!!!!!!! :(

    I'm So CONFUSED!!!!!!!!!!!!!!!!!!!!! :(
  2. Replies
    1
    Views
    708

    Googled Psychrometric and came up with this...

    Googled Psychrometric and came up with this website pretty quick, there were many others...hope this helps...

    http://www.kw-energy.com/psych.htm
  3. Replies
    6
    Views
    848

    Blower relay or blower board bad...? Is someone...

    Blower relay or blower board bad...? Is someone looking over my shoulder?!?! :)
  4. Replies
    16
    Views
    1,648

    I'm sorry, I thought you had lived with this...

    I'm sorry, I thought you had lived with this system for a while....as far as what brand name system you buy, It really dosn't make much difference...try to find a reputable company in your area, or a...
  5. Replies
    16
    Views
    1,648

    Your old AMANA lasted for ten years...which is...

    Your old AMANA lasted for ten years...which is approximately a lifespan for a residential unit.(maybe a little short) Why not go back with AMANA? They have really improved their product line in the...
  6. Replies
    7
    Views
    946

    My first thought for New Hampshire was High...

    My first thought for New Hampshire was High efficiency oil fired boiler and hydronic heat with high effeciency straight A/C. You could even heat your water with it, and put in a towel warmer or two....
  7. Replies
    21
    Views
    2,146

    Gentlemen: How in the F*&^ is this guy going to...

    Gentlemen: How in the F*&^ is this guy going to have a compressor there in a straight cooling system and it be good?
    On a hot day the compressor runs for a while and overheats this is a fact we...
  8. Replies
    21
    Views
    2,146

    The green Slime has been Known to infect systems...

    The green Slime has been Known to infect systems that have gotten moisture in them for one reason or annother...A hole in the condenser coil is one reason why I can think of, also not properly...
  9. Replies
    10
    Views
    2,852

    I would check the expansion valve indoor...it...

    I would check the expansion valve indoor...it would seem your liquid line is restricted somewhere, causing the system to pumpdown...loss of suction pressure...there is probably a restriction entering...
  10. Replies
    21
    Views
    2,146

    Is this a heatpump? If so, you could have a stuck...

    Is this a heatpump? If so, you could have a stuck reversing valve letting hot gas bypass back to the compressor and overheating it...your pump might be OK, but I would suggest further...
  11. Thread: Pool Heaters?

    by trgams
    Replies
    10
    Views
    2,009

    You could try one of these heat-exchangers, a...

    You could try one of these heat-exchangers, a couple of circ. pumps and an aquastat.....

    http://www.flatplate.com/
  12. Replies
    13
    Views
    2,885

    It may not make a difference at all...it depends...

    It may not make a difference at all...it depends on how far your furnace is from the meter...it seems to me if your buddy is cutting the valve off a percentage, he is restricting the flow through the...
  13. Replies
    30
    Views
    4,091

    Pretty countryside...looks like prime deerslaying...

    Pretty countryside...looks like prime deerslaying country. :) The unit looks ok, but as we all know they are all POS's. I bet that unit was a ***** to drag up the extension ladder! LOL :)
  14. Thread: Same old story

    by trgams
    Replies
    5
    Views
    3,413

    HA HA HA!!!! I guess you got a couple of free...

    HA HA HA!!!! I guess you got a couple of free screwdrivers!!! What the hell were they thinking, it's just too easy to prop up this stuff with a couple of tools rather than go to the truck and get a...
  15. Thread: California Roof

    by trgams
    Replies
    50
    Views
    6,159

    OK Squeekie, I see it is insulated...well, you...

    OK Squeekie, I see it is insulated...well, you folks out west do things differently than here I can see that clearly, but different isn't necessarily wrong...I apologise for what I said earlier about...
  16. Thread: California Roof

    by trgams
    Replies
    50
    Views
    6,159

    Hey Squeekie....I'm not trying to put you...

    Hey Squeekie....I'm not trying to put you down..well maybe a little, but, insulation isn't an issue??? What the Fudge are you talking about? Anyways everyone who has responded here so far has...
  17. Thread: California Roof

    by trgams
    Replies
    50
    Views
    6,159

    What the....(scratching my head)....did I just...

    What the....(scratching my head)....did I just wake up in annother dimension again?!!! It sure is pretty! (trying to get along with the local alien beings) LOL :)
  18. Yes, it's recommended, we did check these, also...

    Yes, it's recommended, we did check these, also had to remove and replace the drive pulleys and belts to get the correct design CFM...the belts are holding up well so far.
  19. Replies
    11
    Views
    4,342

    Still not too cool, but that fan is going to blow...

    Still not too cool, but that fan is going to blow towards the building, hence the stains all over the wall from the steam coming off the unit....probably in low ambient conditions. :) PS I love how...
  20. Yes there is a Chiller...180ton Carrier...

    Yes there is a Chiller...180ton Carrier Flowtronic POS...It works pretty good now though...also, that boiler is I think on the order of 4.3 Million BTUH, or there abouts...there is also a steam...
  21. These are just make-up air units...built up...

    These are just make-up air units...built up airhandlers for intake air, this had to be conditioned...


    http://ww2.imagewiz.net/images/hvac/55984_IM000298.JPG
    ...
  22. Replies
    25
    Views
    9,107

    I'll bet it's nice and quiet!!! :)

    I'll bet it's nice and quiet!!! :)
  23. Hey! This has been covered right here before!!!!...

    Hey! This has been covered right here before!!!! :)


    Check this out: http://hvac-talk.com/vbb/showthread.php?threadid=21969


    That furnace looks alot similar to what I saw...Happy reading! :)
  24. Replies
    21
    Views
    5,190

    The only way I see it being close to right: Tie...

    The only way I see it being close to right: Tie both natural draft flues(water heater 3") together with a 3x3x7" tee, run it past your flues for the induced draft furnaces and tie it to your 8"...
  25. Replies
    21
    Views
    5,190

    Tell customer that they need to suffice with one...

    Tell customer that they need to suffice with one water heater...or relocate one...that takes care of the sizing issue.
Results 1 to 25 of 42
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event