Search:

Type: Posts; User: rusty1217

Page 1 of 6 1 2 3 4

Search: Search took 0.00 seconds.

  1. Replies
    27
    Views
    7,255

    I always thought if I went on my own I would have...

    I always thought if I went on my own I would have install trailers. I hate trying to keep service and install stuff on a van, even a sprinter and have everything I need for a job. We have a lot of...
  2. Replies
    19
    Views
    4,246

    I have thought about selling CO detectors to...

    I have thought about selling CO detectors to customers before, but I would imagine it to be another liability. If one failed the lawsuits would fall back on you. I do recommend them to most of my...
  3. Replies
    28
    Views
    1,921

    Why not make it a dual fuel system?

    Why not make it a dual fuel system?
  4. Replies
    25
    Views
    2,204

    We have a genie lift which will lift a condensor...

    We have a genie lift which will lift a condensor high enough for most 1 story buildings, we have also called an electrical shop that has a bucket truck with a hoist, i believe it is rated at 500 lbs....
  5. Replies
    26
    Views
    2,622

    After the new construction bust i was off for...

    After the new construction bust i was off for about 6 months. I lined up a bunch of side work and ran it out of a '99 cavalier and even had a 4'x6' trailer for equipment. It did look funny but got...
  6. Replies
    10
    Views
    1,061

    Just had a humidifier mounted on the front side...

    Just had a humidifier mounted on the front side of the supply start leaking. It took out the board on a friday night. We convinced the home owner to have us move it the next week. We don't usually...
  7. Thread: Fluke 902

    by rusty1217
    Replies
    27
    Views
    6,305

    Been looking at the 902. Have 2 fluke meters and...

    Been looking at the 902. Have 2 fluke meters and never a problem. Got one in '96 at school. It has even been submerged in water. Changed the battery and it works just fine. One of my instructors...
  8. Replies
    17
    Views
    1,183

    How are you filling with water? are you removing...

    How are you filling with water? are you removing it from the furnace or just plugging the drain line? I have never done that before.
  9. Replies
    22
    Views
    1,600

    Wasn't a flame sensor. The oem ignitor was...

    Wasn't a flame sensor. The oem ignitor was longer and I had to modify the mount to get the glow fly to hit the flame right. This was a freebie for a relative that lived 45 minutes away in bfe and...
  10. Replies
    22
    Views
    1,600

    The york had 2 screw per burner. I loosened the...

    The york had 2 screw per burner. I loosened the screw and moved the burners around till I hit the right spot. Putting them together I would have thought the screw would have lined them up well...
  11. Replies
    22
    Views
    1,600

    Didn't see any mention of the fault code. Had 1...

    Didn't see any mention of the fault code. Had 1 york and 1 goodman give me intermittent ignition problems this year. On the york the other tech had cleaned it and it developed a problem. Both of...
  12. Replies
    61
    Views
    4,239

    Not a fan of lennox or carrier furnaces when it...

    Not a fan of lennox or carrier furnaces when it comes to service. It is freaking pain just to clean the dang flame sensor on a lennox...
  13. I cringe everytime I walk in to a pma on either...

    I cringe everytime I walk in to a pma on either of these furnaces. I don't know what the engineers were thinking or why they keep installing these furnaces. They r a service nightmare.
  14. Replies
    17
    Views
    7,969

    I have used nitrogen to break a vacuum on systems...

    I have used nitrogen to break a vacuum on systems where there was lots of moisture, most likely from bad install. It gets trapped in the oil. If I have a hard time getting under a 1000 microns, and...
  15. Thread: Damn dog!!!

    by rusty1217
    Replies
    9
    Views
    1,675

    Had a couple of those this summer...

    Had a couple of those this summer...
  16. Thread: Stolen Tools

    by rusty1217
    Replies
    31
    Views
    5,425

    Luckily the insurance covered all our stuff.

    Luckily the insurance covered all our stuff.
  17. Thread: Stolen Tools

    by rusty1217
    Replies
    31
    Views
    5,425

    One time my van started messing up. The boss had...

    One time my van started messing up. The boss had me take it to the shop and take his truck home. Loaded my tools up on it. Nice pick up with service bed and extra boxes on top. Set up for...
  18. Replies
    18
    Views
    3,254

    I will be looking to buy a set of new gauges this...

    I will be looking to buy a set of new gauges this winter. Just looked at the sman 3 online last night. The price beats out the others, I was worried about the quality but judging from all the...
  19. I was lucky enough to have been taught about...

    I was lucky enough to have been taught about charging to superheat or subcooling in school. With dual thermometers or gauges with 2 temperature clamps I just automatically check both every time and...
  20. Replies
    67
    Views
    10,088

    "Draft hoods supplied with a design-certified gas...

    "Draft hoods supplied with a design-certified gas appliance: certification of a gas appliance design under pertinent national standards includes its draft hood (or draft diverter). Consequently, the...
  21. Replies
    44
    Views
    8,197

    Is this a new unit still under warranty or just...

    Is this a new unit still under warranty or just the warranty on the txv that was replaced? If just the txv, forget the warranty and go with the new tech. You sound like you are totally unhappy with...
  22. Replies
    67
    Views
    10,088

    Never heard of shortening the hood or removing...

    Never heard of shortening the hood or removing the legs totally. Will have to look into that more. All old furnaces had draft boxes before they had draft inducers. I will definitely try to find the...
  23. Didn't Goodman sell a multi-position furnace that...

    Didn't Goodman sell a multi-position furnace that if you used it for a downflow, you just had to rotate the draft inducer.
  24. Replies
    67
    Views
    10,088

    Is it just me or has that draft hood been...

    Is it just me or has that draft hood been shortened by a lot. It looks it is almost sitting flat on the water heater. And is that a copper gas line? Ugh...
  25. Replies
    15
    Views
    2,326

    Recovery machine and vacuum pump should be...

    Recovery machine and vacuum pump should be supplied by the contractor. Refrigerant scales usually r also. Every shop I have worked for has also supplied the torch. Currently use a turbo torch at...