Search:

Type: Posts; User: tlb

Page 1 of 4 1 2 3 4

Search: Search took 0.00 seconds.

  1. Thread: Steamist unit

    by tlb
    Replies
    0
    Views
    452

    Steamist unit

    Anyone tell me where cheapest place to find Steamist units and parts.Have old hotel customer wanting us to check on one.Looked on internet, seems you better have plenty of vasoline and grab both...
  2. Replies
    11
    Views
    968

    Have yall heard they are now recommending to stop...

    Have yall heard they are now recommending to stop on the side of the road and fart in your in gas tank to conserve oil? :grin2:
  3. Thread: duct board

    by tlb
    Replies
    22
    Views
    1,801

    We use ductboard alot.If it is installed...

    We use ductboard alot.If it is installed correctly it is fine.Staple and tape seams good, strap every 4'.You wont have any problems.Yes,in crawl spaces it can be damaged by rodents etc.Overall imho...
  4. Replies
    10
    Views
    988

    Use ductboard:yes:We use pitt when we do...

    Use ductboard:yes:We use pitt when we do metal.Also S" and drive cleat are not the same.Drive will normally be on two narrow sides of duct and the "S" on the two wide sides.
  5. Replies
    5
    Views
    1,145

    Yes, stage 1 Y1-C and stage two Y2-C.Any time...

    Yes, stage 1 Y1-C and stage two Y2-C.Any time your system is running stage 1/Y1 will be energized, even when unit is running on second stage.If you are getting Y2 call from tstat unit will be running...
  6. Replies
    5
    Views
    1,145

    Read your other post so I assume this is an open...

    Read your other post so I assume this is an open loop.We use standard open/close solenoids.As stated before we use manual valves to set gpm.I have seen valves that operate off psi but to me simple is...
  7. Replies
    5
    Views
    1,145

    Yes,we use some sort of manual valve...

    Yes,we use some sort of manual valve ball,gate,etc.We put these on the unit side of the solenoid valves.All you have to do is split the single pipe.Install your valve assemblies then take back to one...
  8. Thread: Workers unions

    by tlb
    Replies
    71
    Views
    5,839

    Ok,was at a house other day and HO brother in law...

    Ok,was at a house other day and HO brother in law was bridge inspector.He went to jobsite to look things over.Noticed two welders arrive and take a seat,guy does his thing and few hours later comes...
  9. Thread: Workers unions

    by tlb
    Replies
    71
    Views
    5,839

    Workers unions

    Do you all think unions are a good or bad thing.I have heard some things that sound sort of counterproductive about unions.Not trying to offend just curious.I dont know that much about them.
  10. Replies
    6
    Views
    1,897

    jBooker56 you were right.Checked draft switch...

    jBooker56 you were right.Checked draft switch with inducer running and it was open.Disassembled venter and got to excavate 4 birds out of the vent pipe.Put back together and worked fine.Crazy why it...
  11. Replies
    6
    Views
    1,897

    Yes,there is a manual reset rollout and a auto...

    Yes,there is a manual reset rollout and a auto reset hi limit in the circuit.Again I have checked the limit circuit at the control board multiple times and it reads closed.Also I forgot to mention...
  12. Replies
    6
    Views
    1,897

    Carrier furnace lockout question

    Have Carrier furnace mod#58MXA100-F-1--16 ser#0503A10693.It is twinned.Was doing scheduled service and found the left furnace locking out on code "13",which is limit circuit lockout.Check...
  13. Replies
    11
    Views
    1,143

    Have replaced some control modules only on units...

    Have replaced some control modules only on units that werent covered by warranty.These units were trane.I would figure you could get just the mod but not sure where.
  14. Replies
    4
    Views
    582

    Thanks for the replies.Ended up putting psi...

    Thanks for the replies.Ended up putting psi regulator valves on each system.Problem solved.Thanks again
  15. Replies
    4
    Views
    582

    noisy water flow on geo open loop

    Have 3 2 stage geo systems hooked to common open loop.Have manual ball valves to regulate flow for hi and low stage.Had to cut back ball valves so much to get gpm down where needed that there is...
  16. Replies
    15
    Views
    1,679

    I did have same problem on smaller york package...

    I did have same problem on smaller york package units.Voltage,cap,amp draw all good but would cut on internal.These were generic motors that we had put on to replace the OEM.We had to upsize from 1/4...
  17. does the needle hold when blower is running? I...

    does the needle hold when blower is running? I would go with heat xger
  18. Thread: 10 ton goodman ac

    by tlb
    Replies
    8
    Views
    619

    more info

    more info
  19. Replies
    11
    Views
    650

    An ultrasonic works off the sound of a leak (same...

    An ultrasonic works off the sound of a leak (same principle as a dog whistle) the detector can hear it even though you cant.You will have to bump the pressure up to get these to work well most of the...
  20. Replies
    3
    Views
    417

    do anything different?

    when you arrive for a no cool\heat call would you change anything in this? 1:get system operational 2:verify proper airflow indoors and out. 3:check charge via superheat\subcooling 4:put the pedal to...
  21. Replies
    25
    Views
    2,720

    I use mapp\oxy.

    I use mapp\oxy.
  22. Replies
    41
    Views
    5,759

    I heard that people form a first impression in...

    I heard that people form a first impression in 3-5 seconds.Which if this is true they base this only on appearance.Your appearance can say I take pride in what I do or I could care less.So I think a...
  23. Replies
    9
    Views
    2,038

    New one on me,have never seen that.Seems to me...

    New one on me,have never seen that.Seems to me this could not work.The txv you were talking about that was restricting, was this on the indoor or outdoor section?Also I have seen outdoor coils with...
  24. Replies
    69
    Views
    6,632

    About the "special" schrader valves.They are only...

    About the "special" schrader valves.They are only on package units not splits.Also I have removed them with two small adjustable wrenches, they screw in half.The shrader stays in the top half.
  25. Thread: heat pump

    by tlb
    Replies
    6
    Views
    797

    The call to the RV is coming from the t-stat in...

    The call to the RV is coming from the t-stat in cooling mode. The only time your control board will generate the RV signal is when the heatpump goes into defrost
Results 1 to 25 of 95
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event