  1. Replies
    2
    Views
    330

    Jace access through Comcast Modem

    A customer recently had a Comcast modem installed at one of our sites. I cannot seem to get the bugger to communicate with the Jace. Does anyone have a cheat sheet or can instruct me as to getting...
  2. Replies
    10
    Views
    692

    Jace Remote access without a static IP

    I have a customer whom is getting a static IP. At this time the communication is lost remotely to the device. Can anyone tell me how to set up another temporary non static IP using the :81?

    TY
  3. Replies
    1
    Views
    232

    Jace remote communication loss

    Has anyone had any remote access drops on any Jace 3.6 ? I have two sites that are doing the same thing with different service providers. One is Comcast and the other is Verizon. I have checked both...
  4. Replies
    5
    Views
    1,040

    DuffyHVAC are you still looking for this...

    DuffyHVAC

    are you still looking for this device?
  5. Replies
    5
    Views
    1,040

    Facilitator

    I still have the device and the operators manual. Do you have the Johnson tools to access and reprogram? Because I do not have.
  6. Replies
    15
    Views
    3,717

    Trane units will run the economizer-If the...

    Trane units will run the economizer-If the economizer does not satisfy the supply air temperature in about 5-10 minutes, it WILL bring on a stage of cooling to try to satisfy the supply temperature...
  7. Replies
    28
    Views
    2,728

    Trane units will bring on the mechanical cooling...

    Trane units will bring on the mechanical cooling if the economizer does not make the supply temperature (55*F) in a certain amount of time. They usually run only the first stage with the economizer....
  8. Is this Voyager a VAV? They can take up to 15...

    Is this Voyager a VAV? They can take up to 15 minutes before a heat is initiated via test mode or a call from the controlling devices. If its an older model, they have cube relay(s) that I have seen...
  9. Replies
    6
    Views
    2,213

    There are 8 radiant loops coming from the supply...

    There are 8 radiant loops coming from the supply and return of the boiler. Each have their own pump and mixing valve. The boiler has its own pump and mixing device internal of the boiler. The boiler...
  10. Replies
    6
    Views
    2,213

    Primary

    Primary
  11. Replies
    6
    Views
    2,213

    Radiant heat boiler piping question

    I walked into a small nighmare. I went on a service call to deal with some noise issues with radiant floor heat. I have a Burnham Reliant boiler that maintains 160* at the boiler. The loop piping is...
  12. Replies
    14
    Views
    2,791

    Service tool

    It may not help you at the moment with a changed password, but you can purchase a Carrier Service tool and access anything you need to via the Carrier network or the connector on the front of the...
  13. I haven't been on a Tracker in some time. Did...

    I haven't been on a Tracker in some time. Did they give you the operating software for a PC?

    When you have had enough, you can see if they have the reliatel board in them that accept a...
  14. Replies
    1
    Views
    539

    Bacnet speed question

    I have an FX-40 running bacnet at a facility. I know this device has limited capabilities, but an engineer has asked if the Baud rate can be ramped up from the current 38+ to 76+ to improve...
  15. Replies
    36
    Views
    7,677

    I hope I didn't ruin your expectations. Unless...

    I hope I didn't ruin your expectations. Unless you work for the government, you will have to work. Sorry for the pain and anguish. It is my beleif that you will find good and not the Evil.:cheers:
  16. Replies
    36
    Views
    7,677

    You can lead a human to knowledge, but you can't...

    You can lead a human to knowledge, but you can't make him think. There are no short cuts in life. Stop leaks do not work. When the oil is trashed and the lubrication fails, the next guy will be...
  17. Replies
    40
    Views
    5,404

    I have used the "Johnson"/Yokagawa for years....

    I have used the "Johnson"/Yokagawa for years. This is the best leak detection device I have ever used or seen in 32 years in the business. Do not look any further, look to find where you can get one....
  18. I hope the water heat is constant. Some people...

    I hope the water heat is constant. Some people like to shut that heat off when the temp. gets warm outside. Just sayin Yo. Can really mess things up and then they will blame the controls tech.
  19. Replies
    22
    Views
    3,469

    Most Liebert or any other computer room...

    Most Liebert or any other computer room condensers are rather thick. It takes a "trained eye" to "really clean it" when it's "way bad dude". I never even trust my own work, therefore I alway double...
  20. Replies
    18
    Views
    2,309

    I feel for you. Always start with the easy stuff....

    I feel for you. Always start with the easy stuff. Power Supply-OK. Control voltage-OK. Reboot-OK. Alway check the stupid plug connectors on a Trane. On the small Voyagers, there is always one near...
  21. Thread: Megging!

    by Beacon Tech
    Replies
    26
    Views
    2,560

    Never had a problem megging anything low or high...

    Never had a problem megging anything low or high pressure myself in 32 years. I don't work on many systems that run the real low pressure refrigerants either (like R-11). Any system without crankcase...
  22. Replies
    14
    Views
    3,394

    Smoke detectors are ALWAYS a life safety device...

    Smoke detectors are ALWAYS a life safety device and should ALWAYS break the control power to any device immediatly including any time delays. Some manufactures have built in control logic for shut...
  23. Replies
    2
    Views
    682

    NVO Space Temp Not updating

    I have a lon building with a newer Tridium (3 Years old tops) and some Honeywell Excel 10 Smart VAV controls. I have one thats not smart anymore. The space temp will not update the current...
  24. Residential Refrigerator/Freezer Question

    I'm going to have to replace my refrigerator/Freezer soon at my home. Since I work in the Commercial/Industrial sector, I do not know much about which Brands are good or bad. I also heard they don't...
  25. Replies
    6
    Views
    1,008

    Would you happen to know the part #? I'll check...

    Would you happen to know the part #? I'll check the part #'s on the ones I have.
  26. Replies
    6
    Views
    1,008

    Javabob, I have some 6400's (6), A telelink...

    Javabob,

    I have some 6400's (6), A telelink which is the obsolete CCN Tel. Com Module, some zone stats (about 6), 1 monitor stat and a bypass control stat and module. I'm not familiar with the TSM...
  27. Replies
    4
    Views
    2,218

    Station running low on Java heap?

    One of the sites I monitor has given me a warning code "Station running low on Java heap". I haven't seen this one yet. Any ideas or fixes?

    Thanks:gah:
  28. Thread: AAON Unit

    by Beacon Tech
    Replies
    31
    Views
    4,502

    Yes, they do put 10 LBS. in a 5 LB. box on the...

    Yes, they do put 10 LBS. in a 5 LB. box on the small units. Good thing you have hot gas bypass, I,m sure you know it runs better with the disconnect on.
  29. Thread: AAON Unit

    by Beacon Tech
    Replies
    31
    Views
    4,502

    Any piece of equipment that gets bounced all over...

    Any piece of equipment that gets bounced all over the Interstate is bound to have problems. I have started hundreds of Aaon units and they have flaws like everyone elses equipment I have started. ...
  30. Replies
    20
    Views
    2,234

    The Cooper SH66A is my choice. I've had one for...

    The Cooper SH66A is my choice. I've had one for over 25 years. Every instrument has its flaws,especially the IR. You have to pay attention to how it does its "work" to be able to trust it. I use the...
  31. Replies
    36
    Views
    7,677

    Stop leak should be outlawed. I've seen it kill...

    Stop leak should be outlawed. I've seen it kill compressors and I will never use it. Learn to repair the leak as the other pros' have stated. I've silver soldered over the galvanized steel and have...
  32. Replies
    10
    Views
    1,914

    Also keep an eye on the superheat. If the...

    Also keep an eye on the superheat. If the Expansion valve is "hunting" (opening and closing rapidly) you may see bubbles appear and disappear. The TXV bulb needs to be mounted tightly. You also need...
  33. Replies
    5
    Views
    1,040

    Johnson Facilitator

    I have a Johnson Facilitator available. Been on the shelf for over 5 years. let me know if you need it or more info.
  34. Replies
    2
    Views
    700

    microzone?

    Are you still looking for these? I have some at a site that have been no longer needed. I can only get them when I get called to the site. What would you be willing to pay for them? They were working...
  35. Replies
    6
    Views
    1,008

    Carrier hard to find controls available

    I have some hard to find and obsolete carrier zone controls, CCN etc... Anyone intersested? Some are new and some are used. I have some 6400's used and some zone stats, bypass controllers and one...
  36. Replies
    5
    Views
    457

    Its an Ax. Thanks for your replies. I will try...

    Its an Ax. Thanks for your replies. I will try them tomorrow.:putergreet:
  37. Replies
    5
    Views
    457

    Trend and history file help.

    I have a Jace running Lon. I recently had to swap out some proprietary VAV controllers with Honeywell Excel 10 smart controllers. All are programmed,commissioned and working well. I can't seem to...
  38. Replies
    23
    Views
    1,932

    johnbeck1000, When you change any pilot...

    johnbeck1000,
    When you change any pilot assembly, please take a very close look at the new one and the old one and compare the two of them. Please note where the "business" happens like the spark or...
  39. Replies
    7
    Views
    502

    CCIKelly I can relate to all of the quotes. My...

    CCIKelly

    I can relate to all of the quotes. My favorite is the second. The third is the reality I have to live with as well as you. The worst is trying to work the controls around everyones value...
  40. Replies
    7
    Views
    502

    CCIKelly, I do believe the point was mapped to...

    CCIKelly,

    I do believe the point was mapped to AI-14. I will check the other things when back on site.

    Great quote by the way.
    Thanks
  41. Replies
    7
    Views
    502

    Controlgeek, Not yet. I believe this sensor...

    Controlgeek,

    Not yet. I believe this sensor can be 24vac or 15VDC, someone else had installed this. Do you think thats worth a try? If so, I will try it next time I visit the site.

    Thanks.
  42. Replies
    7
    Views
    502

    DX-9100 expansion module question

    I have an expansion module XP9102 connected to a DX9100. There is a Humidity sensor running to AI6. All the other analogs are working fine off of this module. I have 15VDC feeding the humidity sensor...
  43. Replies
    15
    Views
    970

    Block the condenser with plastic and "throttle"...

    Block the condenser with plastic and "throttle" the plastic until your pressure reads about the equivelant of an 85*F ambient, then check the subcooling-it should be at least 10*F. If it has a...
  44. Replies
    28
    Views
    2,623

    The boards usualy have triacs (electronic...

    The boards usualy have triacs (electronic switches) for the output relays. Can you remove the output wires at the RTM going to the fan output and see if you have 24 volts. If you have 24 volts at the...
  45. Replies
    23
    Views
    1,932

    :cheers:

    :cheers:
  46. Replies
    60
    Views
    3,422

    Hewitt, Non condensibles suck and can do many...

    Hewitt, Non condensibles suck and can do many weird things. Never trust anything that was done before you showed up. When in doubt "Do the right thing" if you have anything strange happening, recover...
  47. Replies
    18
    Views
    3,493

    What is the model and serial? Is this over 10...

    What is the model and serial? Is this over 10 years old? Can you see the turbulators inside the burner outlet compartment? Are they rotted out? When all else fails, the simple rules for combustion...
  48. Replies
    23
    Views
    1,932

    Power flame is not unlike other burners. The...

    Power flame is not unlike other burners. The pilot assmblies "wear" and it all depends on run time or how many starts. Is this a draft induced commecial burner? The pilot assemblies will only last...
  49. Replies
    25
    Views
    1,871

    Where I am in New Jersey, our equipment is rated...

    Where I am in New Jersey, our equipment is rated at 95* F ambient temperature. 1 ton is equal to 12,000 btu's per hour and that is the maximum amount of work at that can be performed under those...
  50. Inducers do cause a similar problem when they...

    Inducers do cause a similar problem when they short, but also make sure it does not have a separate relay (#1) on a voyager, to bring on the inducer. I recently had one stick on me.
Results 1 to 50 of 68
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event