  1. Replies
    34
    Views
    2,961

    try pressuring the unit back up and soap bubble...

    try pressuring the unit back up and soap bubble your weld joints
  2. Replies
    3
    Views
    1,234

    AMARICAN STANDARD AIR HANDLER

    PROBLEM SOLVED HAD TO RESET DIP SWITCHES. ALSO HEAT PUMP GROSSLY OVER CHARGED. THANKS FOR YOUR RESPONSES
  3. Replies
    74
    Views
    6,373

    CHECK LINE VOLTAGE POLARITY

    CHECK LINE VOLTAGE POLARITY
  4. Replies
    3
    Views
    1,234

    AMERICAN STANDARD AIR HANDLER

    I HAVE AMERICAN STANDARD AIR HANDLER /HEAT PUMP 16 SEER AFTER T-STAT SATISFIED VARIABLE SPEED BLOWER CONTINUES TO RUN RAMPED DOWN FOR SEVERAL MINUTES AS MUCH AS 20 MIN ISW THIS NORMAL?
  5. Replies
    13
    Views
    1,217

    freemind you dont seem to have a clue your state...

    freemind you dont seem to have a clue your state of mind way out there have you led a shelterd life it seems to me if everybody is out to screw you the i suggest you consult a priest or mental health...
  6. Replies
    17
    Views
    2,603

    6"down 4"up

    6"down 4"up
  7. Replies
    40
    Views
    3,629

    this kit comes from trane this is not an after...

    this kit comes from trane this is not an after market fix . this is what trane sells to twin their furnace again pt#baytwin400a
  8. Replies
    40
    Views
    3,629

    :cheers:

    :cheers:
  9. Replies
    40
    Views
    3,629

    you can buy trane twinng kit pt#baytwin400a...

    you can buy trane twinng kit pt#baytwin400a consists of 1 sequencer and relay cost is 29.95 online
  10. Sticky: hang in there .like you i began my career not...

    hang in there .like you i began my career not knowing squat.i rode with techs who taught me tons about the field peaking my intrest.then came school graduated 3.75 gpa twenty years later i find my...
  11. Replies
    10
    Views
    1,041

    odds are a stuck fan relay on control board...

    odds are a stuck fan relay on control board disconnect hi voltage to motor and check with meter.
  12. allways works for me

    allways works for me
  13. a techumshe model aea4440yxa is a 134a compressor...

    a techumshe model aea4440yxa is a 134a compressor should fit your needs
  14. you need to address sealing seams and points of...

    you need to address sealing seams and points of air and moisture infiltration .there should be no way that moisture should seep thru
  15. Replies
    20
    Views
    7,287

    went on a service call about 2yrs ago customer...

    went on a service call about 2yrs ago customer took 1soaker hose and coiled it around condenser coil then wrapped a 4in thick foam rubber piece around the entire coil then coiled another soaker hose...
  16. Replies
    10
    Views
    2,235

    sureley you jest airflow thru the front of the...

    sureley you jest airflow thru the front of the unit is little to none causing high head pressures
  17. Replies
    26
    Views
    4,536

    gotta love planned obsolecence

    gotta love planned obsolecence
  18. Replies
    8
    Views
    3,364

    not so rare thats why you look inside unit for...

    not so rare thats why you look inside unit for factory installed driers .takes a few minutes longer. saves a call back and a frustrated customer.
  19. this is just temporary right? til the right...

    this is just temporary right? til the right replacement could be found ?
  20. Replies
    14
    Views
    2,750

    good GOD at least your guy had the good sense to...

    good GOD at least your guy had the good sense to correct the flaws of the weak minded
  21. Thread: t-stat

    by foobee
    Replies
    2
    Views
    1,073

    do you mean ranco small gray box with dial for...

    do you mean ranco small gray box with dial for coolers ?
  22. Replies
    10
    Views
    942

    check LRA if its close replace compressor start...

    check LRA if its close replace compressor start components check for acid in system and nuetrilize accordinly acidaway and hh suction sucton drier
  23. Replies
    12
    Views
    2,098

    are they still employed? in business remember...

    are they still employed? in business remember this is what makes the rest of us that care look great
  24. lead service tech

    thats why they put the info on the3 data tag . its a starting point.also the EPA REQUIRES A LOG OF REFRIGERANT USED AND SOLD
  25. Replies
    1
    Views
    456

    lead service tech

    20 yrs and still learning something new everyday.