  1. The suction line HAVE to be insulated, beginning...

    The suction line HAVE to be insulated, beginning to end. No exceptions.
  2. Replies
    24
    Views
    723

    Yes, simple 24vt isolation relay to protect the...

    Yes, simple 24vt isolation relay to protect the primary control
  3. Replies
    5
    Views
    283

    Some additional sealing foam strips may be...

    Some additional sealing foam strips may be necessary.
  4. Replies
    24
    Views
    723

    Honeywell 8000 with out side temp sensor. On oil...

    Honeywell 8000 with out side temp sensor. On oil you will also need a simple isolation relay. Call a pro or you will be replacing a primary control as well as possibly a transformer.
  5. Replies
    21
    Views
    945

    Duct issues AND insulation. Fix both and the...

    Duct issues AND insulation. Fix both and the problem will disappear. The key is Manual J AND Manual D and follow local codes/guidelines for insulation and ventilation.
  6. Replies
    17
    Views
    805

    I'm betting he installed a dry R-22 condenser...

    I'm betting he installed a dry R-22 condenser with the old coil. In which case, probably a 1 year warranty.
  7. Replies
    17
    Views
    805

    Depending on the manufacturer, most likely only a...

    Depending on the manufacturer, most likely only a 1 year warranty on the condenser in your situation. Please re-read the rules for the site. Pricing of any kind is forbidden on this site. If you are...
  8. Replies
    8
    Views
    454

    The problem here Joel is this site does not allow...

    The problem here Joel is this site does not allow DIY instructions and advice. While the part you need may be obsolete, any competent tech should be able to retrofit a board and associated sensor(s)...
  9. Replies
    15
    Views
    985

    Have it repaired, as long as it is evacuated...

    Have it repaired, as long as it is evacuated properly and filter drier replaced, no issue. Do not hope for any help from Allied Air (Lennox), you are not likely to get any. I had the same issue on a...
  10. Replies
    12
    Views
    561

    High line ICP products are good.

    High line ICP products are good.
  11. Sorry Phil, the rules on site, which you agree to...

    Sorry Phil, the rules on site, which you agree to when you sign up prohibit DIY advice or instruction. Just adding refrigerant with out knowing how to properly can be bad for your equipment and...
  12. Use 3/4" thick insulated line set (both lines)...

    Use 3/4" thick insulated line set (both lines) and run it in the attic.
  13. A bath room scale would not be accurate enough to...

    A bath room scale would not be accurate enough to weigh in a charge but as a consumer, it would give a ball park idea. I weight EVERY time I use refrigerant I also have a minimum fee (equal to 1/2...
  14. Replies
    17
    Views
    459

    Tony, the reason you are getting no real advise...

    Tony, the reason you are getting no real advise is because of the site rules "No DIY" This holds trues ESPECIALLY when it comes to high voltage and your ability to electrocute yourself. You have to...
  15. If I were you, I'd go with electric. Your cost...

    If I were you, I'd go with electric. Your cost per gallon of heated water will be higher, but you will be able to put this porpoising to bed.
  16. Solid PVC maybe, foam core PVC, no way. The...

    Solid PVC maybe, foam core PVC, no way. The difference is obvious when you pick them up. Go by manufacturers recommendations. As far as purple primer, depends on the area and the inspector, here,...
  17. Replies
    22
    Views
    1,868

    I'd look into a York modulating LP furnace...

    I'd look into a York modulating LP furnace coupled with a higher SEER heat pump. We do a lot of oil work and I wouldn't touch a condensing oil furnace with a ten foot pole. I've seen half a dozen...
  18. Thread: Issues again

    by heaterman
    Replies
    19
    Views
    1,781

    I ended up with several pop-ups this afternoon...

    I ended up with several pop-ups this afternoon when the site tried to load. First issues I've had since the last go round. I'm running Chrome now instead of IE
  19. Replies
    13
    Views
    692

    Duct system is marginal at best. Probably leaks...

    Duct system is marginal at best. Probably leaks like a sieve. Lots of restriction on 4" flex especially if its loosey goosey. Betting the return intake/filter box is restrictive as well.
  20. hvcasolutions: if you are in the trade, as it...

    hvcasolutions: if you are in the trade, as it appears you are, why not apply for pro status and move your questions to the professional forums. You will get better answers and responses.
  21. You won't find that valve any where. The cost of...

    You won't find that valve any where. The cost of upgrading to a 100% safety shut off unit will be high. Outside of that, site rules don't allow for DIY advice or instructions. I would look into a new...
  22. For the same reason they didn't upgrade the...

    For the same reason they didn't upgrade the thermostat I'm guessing;)
  23. There are more than one way to identify the...

    There are more than one way to identify the guilty component. If his detector fails he can try dye in the system. The 3 manufacturers that I deal with say that this will not impact on warranties....
  24. The outdoor sensor is supposed to be run with an...

    The outdoor sensor is supposed to be run with an independent 2 conductor wire. Most contractors cheap out and use a multi conductor cable to do all of the functions of the outdoor section of the heat...
  25. Not for naught. You have grasped the concepts of...

    Not for naught. You have grasped the concepts of what should be. Now communicate with the powers that be at the company that sold your system to you. Some companies might consider you a pain in the...
Results 1 to 25 of 500