Search:

Type: Posts; User: Robert norton

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    18
    Views
    1,368

    Plastic line set

    My supply house counter guy said they are getting line set made from plastic braze at coil and condenser then the rest is plastic is this for real
  2. Tool for cutting round holes in Sheetrock

    Guys just landed 2 attic installs where I need to cut 6,7,8 " holes in attic in somewhat of a confined space what tool is everyone using thanks
  3. Replies
    9
    Views
    659

    Did the original post speak of running out of hot...

    Did the original post speak of running out of hot water while in the shower
  4. Replies
    9
    Views
    659

    Are you having this problem at the shower only...

    Are you having this problem at the shower only could also be a bad symmons shower valve
  5. Replies
    473
    Views
    44,051

    How do you guys carry your clamp sensors between...

    How do you guys carry your clamp sensors between jobs .i don't want to have to disconnect them every time but afraid if I don't they'll get damaged
  6. Replies
    473
    Views
    44,051

    Thanks

    Thanks
  7. Replies
    473
    Views
    44,051

    Can I get them with the scissor sensor

    Can I get them with the scissor sensor
  8. Replies
    473
    Views
    44,051

    What your phone number or website I want a set of...

    What your phone number or website I want a set of the dc ak 900
  9. Replies
    24
    Views
    2,668

    I have a 2 stage Ruud furnace that once a month...

    I have a 2 stage Ruud furnace that once a month amber light blink clean it and I comes back in a month later replaced sensor now gonna change the board this is direct vent to outside 12 ft above the...
  10. Replies
    35
    Views
    5,864

    Portable easy to carry oxy/acet kit

    Need a good oxy / acet kit I can drag in attics and up ladder must be able to braze up to 7/8 tubing
  11. Replies
    39
    Views
    5,875

    I had a Ruud 2 1/2 split system in a attic have...

    I had a Ruud 2 1/2 split system in a attic have same problem it was last year new install came out 2times with scroll running backwards hard to find what was causing problem it was the condensate...
  12. Replies
    8
    Views
    2,283

    Fieldpiece infrared leak detector

    Any reviews ? I work on 22 and 410a
  13. Replies
    3
    Views
    781

    Rheem academy has troubleshooting online...

    Rheem academy has troubleshooting online classroom .i used to sell Trane they had a little book that had everything from checking an igniter to troubleshooting an ECM motor looking for same info for...
  14. Replies
    3
    Views
    781

    Ruud/Rheem rgrm

    Is there a training cd or down load for the rgrm I have installed a bunch of these furnaces and thought they were coming out with one
  15. Replies
    2
    Views
    671

    Fieldpiece sc77

    Can the fieldpiece sc77 multimeter measure millivolts I'm looking into this multimeter but still have some old steam or gravity hot water boilers that have millivolt burner circuits
  16. Replies
    14
    Views
    2,577

    R-422b freon

    Anyone use nu-22b (r-422bfreon) for r22 jobs how difficult ??
  17. Replies
    10
    Views
    1,058

    What heater is a Navien not involved 2 pipe...

    What heater is a Navien not involved 2 pipe terminates to outside different part of house
  18. Replies
    10
    Views
    1,058

    Ruud rgpn 80 plus furnace

    I installed a Ruud rgpn furnace in 2005 vented unit into existing b vent air for combustion from basement.Custumer calls yesterday says making bedroom in basement making my install in a confined...
  19. Replies
    3
    Views
    541

    GE gas water heater

    What size star torque screwdriver do you use to remove ge waterheater door
  20. Replies
    30
    Views
    3,890

    Best knee pads

    Just finished install in crawl space need new knee pads mine are terrible which ones are the best
  21. Replies
    73
    Views
    7,122

    Where I am I've brought samples to a lab scrape...

    Where I am I've brought samples to a lab scrape the coil and gathered the material lab will tell you if chemical,what it is and where it likely came from if you do it any other way your just guessing...
  22. Replies
    46
    Views
    3,963

    My garmin gps coyld get lost anywhere

    My garmin gps coyld get lost anywhere
  23. Replies
    3
    Views
    553

    Which is better

    Zebra or techmate troubleshooting ecm blower motors
  24. Replies
    15
    Views
    1,673

    Making the biggest bubbles

    When searching for a leak how much nitro (psi)do you fill system to to make best bubbles
  25. Replies
    3
    Views
    439

    I put ballvalve on all my returns on my supply i...

    I put ballvalve on all my returns on my supply i come out of the boiler with a nipple then a 90 from that a riser nipple into a tee which i put a drawoff in one side of the branch out of the other...