  1. general question for all you professionals..

    Forgive me if this is the wrong place for this post. I was looking at the wall of shame area, came across the HVAC system built by the engineer, and I wonder if any of you add components to your...
  2. Replies
    3
    Views
    276

    Filter is always perfectly clean. But if is was a...

    Filter is always perfectly clean. But if is was a dirty filter and therefore bad indoor airflow, wouldn't that tend to lower the suction and trip out on low pressure?
  3. Replies
    3
    Views
    276

    high pressure trip.

    Goodman 2-stage heat 16 seer heat pump, communicating system. Once in a while, via the t-stat I will check for error codes. Found that over the past 2 months, it has tripped out on high pressure /...
  4. Great news. Thanks for the reply.

    Great news. Thanks for the reply.
  5. That's my question too. Was it just a "shot in...

    That's my question too. Was it just a "shot in the dark to shut the guy up" board or is it a documented problem that now has a verified fix.
  6. I've had the HP for a year, and this is the first...

    I've had the HP for a year, and this is the first time anyone anywhere has ever said anything. Couldn't have a conversation at all, then suddenly Goodman has a new board and tells my tech "problem...
  7. Goodman no indoor blower error code, solved?

    Posted about this before, but no one here was able to offer help, but have helped in so many other ways I thought I would share this:
    3 ton 16 seer 2 stage HP with modulating gas furnace and CTK02...
  8. So is it safe to assume that no one has ever done...

    So is it safe to assume that no one has ever done this? And also no one has ever looked at the network communications as a computer and could benefit from cabling as such?
  9. Any Goodman / Amana guys have thoughts?

    Any Goodman / Amana guys have thoughts?
  10. twisted pair for communication wires, maybe solve occasional communication glitches.

    Goodman communicating system, uses a 4 wire hook up. I saw in the manual that communications can be improved if shielded, twisted pair cable is used for the data lines. So that would mean, as I...
  11. random thoughts after first winter with dual fuel system

    Well, I guess with this winter it might be far from over. Goodman 2 stage 16 seer HP with modulating propane furnace and CTK02 t-stat. Overall, I just love this system. I am amazed how well the HP...
  12. It plugs directly into the board, so not exposed....

    It plugs directly into the board, so not exposed. But probably a bad connection, unless it is a board problem (bad solder joint, hairline crack, etc. I will ask him when it comes out in spring,...
  13. outdoor ambient temp sensor blanking out.

    Goodman 2 stage 3 ton HP, with modulating furnace and CTK02 t-stat. During our first real cold snap about a month ago, below zero outside, come home and the HP is running. I have the dual fuel temp...
  14. Replies
    11
    Views
    582

    I understand.. if it isn't cheaper for you then...

    I understand.. if it isn't cheaper for you then it might as well sit in my garage from your point of view. That makes sense, and I appreciate your honesty. I am in NE Ohio, could this stuff even be...
  15. Replies
    11
    Views
    582

    No clue what it is worth, but I could google it. ...

    No clue what it is worth, but I could google it. Any fair price is better than what I am getting for it sitting in the garage. Can the stuff be shipped without a hassle?
  16. Replies
    11
    Views
    582

    the original nat gas burner and valve for an 80K...

    the original nat gas burner and valve for an 80K Goodman GMVM, never used. The furnace was converted to Propane. And when I bought my house in 1999 it had an R22 AC unit that was not working quite...
  17. Replies
    11
    Views
    582

    can a homeowner sell stuff here?

    Like the subject says..
  18. Replies
    4
    Views
    346

    thank you very much.

    thank you very much.
  19. Replies
    4
    Views
    346

    No picture, and frost was not thick. It was...

    No picture, and frost was not thick. It was probably just starting to restrict airflow, hence the slight drop in temperature rise.
  20. Replies
    4
    Views
    346

    outdoor coil frosting in a pattern.

    Perfect conditions yesterday for frosting of a heatpump. I noticed mine was frosting in a pattern, that eventually filled in almost completely before it went into defrost. When it was completely...
  21. Replies
    8
    Views
    642

    Thanks for the replies. But why was this moved...

    Thanks for the replies. But why was this moved to "tech to tech"? I am not a tech!
  22. Replies
    8
    Views
    642

    propane vs. natural gas

    See a lot of threads here pertaining to this.. But exactly why is propane harder on equipment than natural gas? Never lived in the city, been on propane my whole life, nearly 50 years.
  23. Replies
    15
    Views
    804

    Agreed on the 60k, but too late now! Regarding...

    Agreed on the 60k, but too late now! Regarding the ductwork, in my case I am sure that is okay even for the furnace I have, on high fire with proper temp rise, the static pressure in the ducts are...
  24. Replies
    13
    Views
    837

    Oh... well, who knows where the heck that little...

    Oh... well, who knows where the heck that little bracket went! So essentially the little sensing bulb is out in the weather, okay, then where it is now is a reasonable place. My installer told me the...
  25. Replies
    13
    Views
    837

    I have painted an incorrect picture for you, I am...

    I have painted an incorrect picture for you, I am sorry about that! This HP has a temp sensor on about a 12" lead that plugs directly into the main board of the HP. It is not connected to the...