Search:

Type: Posts; User: keywest

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    9
    Views
    1,494

    make sure the liquid line solenoid is not...

    make sure the liquid line solenoid is not sticking,check the txv,make sure the dump valve is not stuck open,and water inlet valve.
  2. Thread: question

    by keywest
    Replies
    1
    Views
    586

    where can i find a schematic for a mitsubishi...

    where can i find a schematic for a mitsubishi freezer shipping container,
  3. Replies
    25
    Views
    7,544

    you can learn alot from a dummy

    you can learn alot from a dummy
  4. Replies
    28
    Views
    2,824

    check your evaporator fans make sure at right rpms

    check your evaporator fans make sure at right rpms
  5. Replies
    8
    Views
    1,550

    you can use them they work fine

    you can use them they work fine
  6. Replies
    30
    Views
    3,369

    sounds like a bad electrical connection...

    sounds like a bad electrical connection somewhere.or the blower is under alot of strain from the pully assembly
  7. Replies
    12
    Views
    2,080

    ive had this problem before make sure that when...

    ive had this problem before make sure that when the system gose into defrost that the fans shut off
  8. Replies
    22
    Views
    3,481

    you should have brought your shorts with you and...

    you should have brought your shorts with you and went swimming
  9. Replies
    28
    Views
    1,950

    hoshizaki

    hoshizaki icemachines are way over priced.
  10. Replies
    22
    Views
    1,429

    ive had this problem with iceomatic if the...

    ive had this problem with iceomatic if the icemaker doesnt drop the ice,there is a hidden 2 wire switch that is hidden under the armaflex on the suction line i think your problem is there its a...
  11. Replies
    28
    Views
    1,950

    there are manitwoc icemachine out there that are...

    there are manitwoc icemachine out there that are still working that are 20 years plus nothing chipping
  12. Replies
    28
    Views
    1,950

    the only thing they have good are the s/s...

    the only thing they have good are the s/s evaporators
  13. Replies
    3
    Views
    1,264

    has anyone worked on cold tech refrigerators or...

    has anyone worked on cold tech refrigerators or freezers what do you think about there designs
  14. the finns on the coil are still straight

    the finns on the coil are still straight
  15. what causes a evaporator copper line to deflate...

    what causes a evaporator copper line to deflate into a u
  16. Thread: Scottsman CM3

    by keywest
    Replies
    8
    Views
    1,422

    was the machine on/off switch turned to ice

    was the machine on/off switch turned to ice
  17. Replies
    3
    Views
    3,029

    they were bought buy cornelious refrigerators...

    they were bought buy cornelious refrigerators there shematics are the same as ross temp dont think there in operation anymore
  18. Thread: KM-900MRH

    by keywest
    Replies
    4
    Views
    1,109

    check the thermister i think your problem might...

    check the thermister i think your problem might be there
  19. Replies
    11
    Views
    1,598

    make sure that the tstat bulb is in the right...

    make sure that the tstat bulb is in the right place and pushed in far enough. if it is then replace with ranco A12701
  20. Thread: Floral Walk-in

    by keywest
    Replies
    11
    Views
    1,294

    have one forsale email teenyaking@aol.com

    have one forsale email teenyaking@aol.com
  21. Replies
    9
    Views
    1,144

    txv systems last way longer than captube systems,...

    txv systems last way longer than captube systems, but if you should get a captube system get a true freezer,the compressors are located at the bottom of the unit,its the same...
  22. Replies
    26
    Views
    3,136

    it should have plugged the filter,before the...

    it should have plugged the filter,before the captube, make shore the end of captube is open, if not replace the whole captube, there only about 8 dollars
  23. Replies
    2
    Views
    1,047

    you might check to see if water is leaking from...

    you might check to see if water is leaking from the icemaker
    which would explain water in the bottom of the freezer someone may have broken something by craming food in the freezer
  24. Replies
    10
    Views
    1,241

    You might want to check the captube size and...

    You might want to check the captube size and length if you put to much freon in a traulsen by 5 ounces more or less the coil wont get cold enough this is a critical charge system if it doesnt have a...
  25. Replies
    5
    Views
    2,560

    you might want to try ARS supply out of...

    you might want to try ARS supply out of oakland,ca they use to sell ross temp.also they changed the name of ross temp to cornelius icemachines the shematics are the same ass the old ross temp...
Results 1 to 25 of 26