  1. Virgin Seeking Certain Geo Thermal Photos Please Help

    Hi, I am seeking Photos of Refrigerant being used to cool water. Can anyone provide any links or Photos of how the Refrigerant Coil or tank Cools the water exiting the ground, and how it works threw...
  2. Replies
    38
    Views
    763

    I found a bit, it measured 1.8mm on my meter and...

    I found a bit, it measured 1.8mm on my meter and when I toggled the Decimal switch it read .071 I hope to get this done in the next day! It rained and the unit is in chirt so it will be a mess right...
  3. Replies
    38
    Views
    763

    Screw this man Between Me and dad and lowes I...

    Screw this man Between Me and dad and lowes I know I can find a 1.8MM bit, Ima get it as close as I can and drill this sucker out!!!!

    Just convert MM to DECIMAL, 1.8MM = right at .071 Dec

    This...
  4. Replies
    38
    Views
    763

    This may be Cheaper!...

    This may be Cheaper! http://www.ebay.com/itm/1-80mm-071-Solid-Carbide-Drill-Bit-w-1-8-Shank-Brand-New-CNC-Dremel-/161132840810?pt=LH_DefaultDomain_0&hash=item258444076a
  5. Replies
    38
    Views
    763

    They're called Bullet pistons and my local...

    They're called Bullet pistons and my local Johnston company, or out of town one can get it for a few dollars but shipping total is 17.99 So I cancelled. I think they rip me off on the shipping so i'm...
  6. Replies
    38
    Views
    763

    I am unable to To get this piston. I checked with...

    I am unable to To get this piston. I checked with 4 supply houses and nobody can help. All say go to nordyne. This is crazy cause I have several Coils with these same .67 pistons. Its like noboxy...
  7. Replies
    38
    Views
    763

    BTW, for the leaky valve, I removed the Lock Ring...

    BTW, for the leaky valve, I removed the Lock Ring and removed the fitting from the housing when the unit was cut open. I installed a New Green Oring as the Old one was Torn. I may not got the right...
  8. Replies
    38
    Views
    763

    Thank you, I have one ready for pickup I'll pull...

    Thank you, I have one ready for pickup I'll pull it down and install this.
  9. Replies
    38
    Views
    763

    Thanks! How do you have access to this...

    Thanks! How do you have access to this information? Is this something I could have found myself? thanks.
  10. Replies
    38
    Views
    763

    For the condensor or evap?

    For the condensor or evap?
  11. Replies
    38
    Views
    763

    Photos

    Thanks Much Appreciated:grin2::cheers:
  12. Replies
    38
    Views
    763

    its a 3 ton, the outdoor temp was about 94, then...

    its a 3 ton, the outdoor temp was about 94, then about 84 I got the same readings each day or close to it.
  13. Replies
    38
    Views
    763

    I changed the Reversing Valve today, Yeah Remind...

    I changed the Reversing Valve today, Yeah Remind me never EVER do that again! Its just pure work! The system is going and it has a delta T of 19.5 on a mid vent.

    The suction sat temp is 43 and...
  14. Replies
    38
    Views
    763

    Its back together, line temp stayed at 64,,,,...

    Its back together, line temp stayed at 64,,,, Whatcha wanna bet if I walk outside and Kicker real hard the 64 will drop down to something lower.... I hate these valves, Wonder If I can put a manual...
  15. Replies
    38
    Views
    763

    I'm convinced its the Reversing valve, (its all...

    I'm convinced its the Reversing valve, (its all thats left) that has to be what it is. I would remove it tonight but my torch is out. I will go pull a vacuum and get it back together so I can have...
  16. Replies
    38
    Views
    763

    I was really expecting a diff orfice, maybe this...

    I was really expecting a diff orfice, maybe this one is still wrong?
  17. Replies
    38
    Views
    763

    Well the Metering device is in my hand, it has...

    Well the Metering device is in my hand, it has 67.67 on it... So now what gives? Also, there was a dark greyish tent on it that wiped clean.
  18. Replies
    38
    Views
    763

    Lol @ u guys. Its 10:35PM and cool tonight, I...

    Lol @ u guys.

    Its 10:35PM and cool tonight, I told her to run it till shes satisfied then before it cuts off ima switch the stat wide open and run out and puller down into herself so that When I...
  19. Replies
    38
    Views
    763

    I'm going with wrong Metering device from here...

    I'm going with wrong Metering device from here thanks guys for pointing me to this!...
  20. Replies
    38
    Views
    763

    Any more comments on this? Could it be the...

    Any more comments on this?

    Could it be the wrong orfice?
  21. Replies
    38
    Views
    763

    i'm not sure what that is, never used any. Is...

    i'm not sure what that is, never used any. Is this something the supply house would have? Thank you..
  22. Replies
    38
    Views
    763

    Thats a sh of 13 and SC of 35

    Thats a sh of 13 and SC of 35
  23. Replies
    38
    Views
    763

    Line Temp outdoor at unit is 54F actual line and...

    Line Temp outdoor at unit is 54F actual line and Saturation gauge at 41 (70 Psi)

    Line Temp liqud 127F on gauge saturation about (290 PSI) and 91.4F line temp

    No Filter
  24. Replies
    38
    Views
    763

    Delta T 57 Supply mid ways vent and 73 Return....

    Delta T 57 Supply mid ways vent and 73 Return. 16F on trunkline B furtherest.
    Trunkline A has a better delta T of about 1 degree. 56.2 SUpply mid ways and same 73 return.
  25. Replies
    38
    Views
    763

    Start Unit let run for 4 mins read line temp at...

    Start Unit let run for 4 mins read line temp at coil to be 64F, wait for a total of 5 mins drops to 55F, let run 2 more mins observe another drop. I have 54F at Closest Vent, and 55 At Mid way Vent. ...