  1. Replies
    7
    Views
    1,051

    Nice job on the install but the duct guy should...

    Nice job on the install but the duct guy should have used a caulking gun to do the sealer or atleast a smaller brush, that's a lot of sealer on them ducts and takes away from your good job
  2. x2

    x2
  3. Replies
    27
    Views
    3,591

    that is not all that counts, The unit is too...

    that is not all that counts, The unit is too close to the wall it will not breathe right and should have replaced the disconnect as well, anyway NEATNESS helps show the customer that you are a...
  4. Replies
    30
    Views
    2,186

    sounds like a good offer and sounds like you...

    sounds like a good offer and sounds like you already made up your mind, need to have a boss you can talk too and get results, probably why I have been with my company for 14 yrs and counting
  5. Replies
    12
    Views
    780

    x2

    x2
  6. Replies
    19
    Views
    1,011

    try using a sharpie over the nameplate go over...

    try using a sharpie over the nameplate go over the numbers and rub off with your finger should "raise" the numbers up for you to be able to see
  7. Replies
    24
    Views
    2,100

    nice job but I would have put that concentric out...

    nice job but I would have put that concentric out a little further and why no purple cleaner here in mass required just asking
  8. if the name plate is still on unit sometimes you...

    if the name plate is still on unit sometimes you can run a sharpie over the m/n s/n rub it with your finger to remove excess ink and read numbers through the marker
  9. Replies
    13
    Views
    2,860

    that is fn discusting

    that is fn discusting
  10. Replies
    19
    Views
    3,340

    that is the classic Monday morning after hard...

    that is the classic Monday morning after hard weekend or the rush to get out on Friday unit
  11. Replies
    18
    Views
    2,793

    did the o so smart college kids install that...

    did the o so smart college kids install that themselves?
  12. Replies
    14
    Views
    2,051

    x2 using hot water to melt ice works very...

    x2 using hot water to melt ice works very quickly, imo faster than a heat gun
  13. they should send the bill for the new unit...

    they should send the bill for the new unit install to the other company and tell them since they pulled all the wiring out and bypassed safeties they should pay for the new unit and cancel that...
  14. Replies
    11
    Views
    2,073

    who in Their right mind would do a job like that...

    who in Their right mind would do a job like that and think "wow that looks good "
  15. Replies
    11
    Views
    2,073

    and it won't cost too much to run that in a/c...

    and it won't cost too much to run that in a/c with ducts not being insulated? and is that all 1 ft jts and a couple of elbows or am i missing something?
  16. Replies
    18
    Views
    2,767

    i would have put shut off valves before and after...

    i would have put shut off valves before and after pump for easier future replacement of pump instead of having to drain down whole system, but i understand broke friend and just trying to get it...
  17. Replies
    9
    Views
    570

    the "by pass " is actually a check valve used if...

    the "by pass " is actually a check valve used if the unit was put on a heat pump am stand and trane do that with all there indoor coils ( at least all that I have seen ) so everyone of them can be...
  18. Replies
    41
    Views
    6,301

    i was thinking " Beverly hill billies " myself...

    i was thinking " Beverly hill billies " myself :grin2:
  19. Replies
    14
    Views
    2,184

    you def need to call code enforcement that is...

    you def need to call code enforcement that is just awful looking, that wiring could not have been done by an electrician at least not a good one
  20. you can go with no trap on the ac because it is...

    you can go with no trap on the ac because it is an updraft blower and will always be positive pressure on the drain but no do not go with out a trap on furnace especially if tying in drains together....
  21. Replies
    6
    Views
    400

    if it is a 3 ph comp try to reverse phasing on...

    if it is a 3 ph comp try to reverse phasing on it, had an old timer tell me to do that once and it worked, got better pressures, it did trip oil pressure switch a week later, and found there is apick...
  22. and make sure to use the right oil i found out...

    and make sure to use the right oil i found out the hard way that not all air compressor oils are the same,i had replaced a bad compressor and went back a week later to change oil and compressor was...
  23. Replies
    5
    Views
    480

    maxi-vac makes a good one with a wand that if you...

    maxi-vac makes a good one with a wand that if you pull handle 1 way it is low pressure to apply the cleaner,push it the other way for high pressure rinse works good get it at united refrigeration or...
  24. Thread: on call

    by Mike Doran
    Replies
    134
    Views
    11,056

    when i was first doing on call had one of the...

    when i was first doing on call had one of the senior techs that i got along with tell me to call him if i ever got into a situation i could not handle at any time night or day, that helped ease my...
  25. is the ductwork " bullnosed " under the rtu? i...

    is the ductwork " bullnosed " under the rtu? i have a couple of units that the installing contractor did this to on 2 200 ton units and could not get the static down in the ducts have to run duct...