Search:

Type: Posts; User: indy2000

Page 1 of 12 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    409
    Views
    53,846

    is this a tiered system?

    is this a tiered system?
  2. Replies
    409
    Views
    53,846

    what is DVS,, mine reads BTJ?

    what is DVS,, mine reads BTJ?
  3. Replies
    409
    Views
    53,846

    What do figure the master plan is?

    What do figure the master plan is?
  4. Replies
    5
    Views
    360

    Good choice What size? What is the climate...

    Good choice

    What size?

    What is the climate like, ambient outside temps?
  5. Replies
    5
    Views
    360

    see that type liquid temp on all our low temp...

    see that type liquid temp on all our low temp screw packages

    its a way of increasing capacity of the expansion valves, not the evap.

    that is why the liquid line is always insulated.

    also...
  6. Replies
    74
    Views
    3,161

    Its 3 phase

    Its 3 phase
  7. Replies
    74
    Views
    3,161

    obviously the phase to phase short, only happened...

    obviously the phase to phase short, only happened when you were there?

    the breaker would have been tripped, prior to your arrival.
  8. Replies
    74
    Views
    3,161

    If the comp got warm You will have current...

    If the comp got warm

    You will have current flowing and it can be measured

    Ie LR amps
  9. Replies
    74
    Views
    3,161

    do you see a possible, not needed compressor...

    do you see a possible, not needed compressor change out?

    I think I do
  10. Replies
    74
    Views
    3,161

    please reconsider that comment scroll is...

    please reconsider that comment

    scroll is directional, and so are some recips.
  11. Replies
    74
    Views
    3,161

    I do remember in school, they tested you to ID...

    I do remember in school, they tested you to ID C-S-R with an OHM meter...

    but its nicer to have them clearly marked.
  12. Replies
    74
    Views
    3,161

    really? must be a generic terminal block they...

    really?

    must be a generic terminal block they are using?

    haven't come across it, yet.
  13. Replies
    74
    Views
    3,161

    are you sure the model number is correct? ...

    are you sure the model number is correct?

    cannot find any specs.

    there is some confusion in your post,,,you state a 3PH unit, yet are testing common, start, and run terminals?

    can you take a...
  14. Thread: Unions

    by indy2000
    Replies
    11
    Views
    891

    union sets min pay if you are worth more,...

    union sets min pay

    if you are worth more, demand more

    I make well over min pay, my employer thinks they are getting a good deal
  15. I don't come cheap but I could fill your need

    I don't come cheap

    but I could fill your need
  16. Replies
    1
    Views
    344

    find union contractor list for that local and...

    find union contractor list for that local

    and go to companies personally
  17. Replies
    409
    Views
    53,846

    sounds like you are calling for a ...

    sounds like you are calling for a

    re-declaration of independence

    I believe its too late, the pieces are in place, the table is set

    the only outcome will be a world consisting of ONE country...
  18. Replies
    409
    Views
    53,846

    sure can, just ask the reserve to print more...

    sure can, just ask the reserve to print more money.....and give it out

    doesn't everything magically appreciate, and growth is endless
  19. thank you

    thank you
  20. Replies
    2
    Views
    290

    get a contractor list, and go out to the shops.

    get a contractor list, and go out to the shops.
  21. hourly rate? residential, commercial,...

    hourly rate?

    residential, commercial, industrial?
  22. 120-140 is what I would move for def not...

    120-140 is what I would move for

    def not something one would pay a tech for restaurant work

    but it was worth a try

    good luck again
  23. 120-140 is what I would move for

    120-140 is what I would move for
  24. to go there I would have to take a substantial...

    to go there I would have to take a substantial hit in compensation.....if that is so

    restaurants are then a def no go.

    If my pay is matched, I would consider it.
  25. affirm

    affirm
  26. damn everything sounded good 'cept the...

    damn

    everything sounded good

    'cept the restaurant portion

    good luck.
  27. Replies
    6
    Views
    333

    lesson never move the wires until after...

    lesson


    never move the wires

    until after you meggar for the short
  28. 407c needs poe we have tried 407F in med temp...

    407c needs poe

    we have tried 407F in med temp coolers with so so results, also needs poe oil changes.

    404a and 507 are scheduled by snap in 2016
  29. Replies
    17
    Views
    1,067

    a gfci trips, at certain current leakage to...

    a gfci trips, at certain current leakage to ground.

    if you use a meggar to simulate power for this leakage, you will find the leakage.
  30. Replies
    9
    Views
    785

    the odds are in your favor, someone will give you...

    the odds are in your favor, someone will give you a chance.

    someone gave me a chance, and I in turn, gave someone else a chance.

    but you got to get out there, and meet that someone.
  31. Replies
    9
    Views
    785

    get a list of contractors for your interested...

    get a list of contractors for your interested locals.......

    go see each contractor in person, and don't take no for an answer,, tell the prospective company what you can do, and let them know it...
  32. Replies
    8
    Views
    602

    thanx, but that is a little low, esp for the cost...

    thanx, but that is a little low, esp for the cost of living in southern CA.

    thank you for the quick response.
  33. Replies
    8
    Views
    602

    thanx for the update. looking at higher HP and...

    thanx for the update.

    looking at higher HP and tonnage, unless you want to pay the same, which I doubt.
  34. Replies
    8
    Views
    602

    what type HP or tonnage does this company...

    what type HP or tonnage does this company service/install?
  35. Replies
    16
    Views
    2,952

    Oddity.... how are you making out?

    Oddity....

    how are you making out?
  36. Replies
    8
    Views
    1,367

    do both....why limit yourself? you should try...

    do both....why limit yourself?

    you should try to know as much as you can, the more you know the more valuable you become.....

    We have no choice at our shop,,,,we are expected to be able to work...
  37. what is top then?

    what is top then?
  38. you got that right. hard to budget for "We...

    you got that right.

    hard to budget for "We offer excellent pay"

    I think most are scared to say actual TOP level pay.
  39. rate of pay is?

    rate of pay is?
  40. $32/hr....:eek2: I think you are looking for...

    $32/hr....:eek2:

    I think you are looking for an apprentice...
  41. Replies
    27
    Views
    1,934

    how is the condensate line piped in? it should...

    how is the condensate line piped in?

    it should be like a sewer drain to prevent vapor lock.

    if the receiver is way down below, we usually add a vapor line to limit the vapor lock between cond...
  42. you top out at $74,000?really?

    you top out at $74,000?really?
  43. Replies
    38
    Views
    3,166

    nice.

    nice.
  44. if the unit did not come with those accessories,...

    if the unit did not come with those accessories, then you don't need them

    I am hoping it was engineered properly.

    Why haven't you talked with drakes tech or engineer on this matter?

    I am no...
  45. metering devices have nominal ratings, ie at...

    metering devices have nominal ratings, ie at certain conditions, each valve has its own particular ratings, as conditions change.

    I would look at your eev manufacturer and find the 'too much'...
  46. Replies
    38
    Views
    3,166

    at your age, you have everything cept experience...

    at your age, you have everything cept experience in this field.......

    go to 469, get the contractor list, and find a job with one of those companies to start your apprenticeship ASAP

    you can do...
  47. you reduce your capacity when you reduce head...

    you reduce your capacity when you reduce head pressure too much.

    you should be able to find correction factors for pressure drop across the metering device...

    most likley from the eev...
  48. Replies
    6
    Views
    918

    their list should be on their website

    their list should be on their website
  49. what is your goal here? EEV are ideal for...

    what is your goal here?

    EEV are ideal for floating head, what makes you think that your equipment is not functioning as advertised?

    the EEV, will determine amount tonnage needed.

    it is not...
  50. Replies
    6
    Views
    918

    find your local ua office, get a contractor list,...

    find your local ua office, get a contractor list, and begin your apprenticeship.