Search:
Type: Posts; User: puniverse
Search: Search took 0.01 seconds.
-
11-05-2012, 12:45 AM
Thread: Trane Rover V7.1 Upgrade
by puniverse- Replies
- 12
- Views
- 842
I need it too. Can you email me. Thanks
I need it too. Can you email me. Thanks
-
11-04-2012, 08:48 PM
Thread: Trane Rover V7.1 Upgrade
by puniverse- Replies
- 12
- Views
- 842
Can you please email me... Thanks
Can you please email me... Thanks
-
10-29-2012, 02:04 PM
Thread: Trane Rover V7.1 Upgrade
by puniverse- Replies
- 12
- Views
- 842
Do you happen to have the main software install...
Do you happen to have the main software install files for v6? Would really appreciate it. Email me with any info. Thanks.
-
10-29-2012, 02:03 PM
Thread: Trane Rover V7.1 Upgrade
by puniverse- Replies
- 12
- Views
- 842
Do you happen to have the main software install...
Do you happen to have the main software install files for v6? Would really appreciate it. Email me with any info. Thanks.
-
10-29-2012, 11:53 AM
Thread: Trane Rover V7.1 Upgrade
by puniverse- Replies
- 12
- Views
- 842
I believe it is on the Trane website under...
I believe it is on the Trane website under downloads.
-
06-13-2011, 10:08 PM
Thread: Anybody got Alerton manuals?
by puniverse- Replies
- 14
- Views
- 1,578
or I figured it out. I had to click on renumber...
or I figured it out. I had to click on renumber vlcs. Now I have another problem. What I had to do was copy one of the other devices with same box size because all the vav's have no application. I...
-
06-10-2011, 11:04 PM
Thread: Johnson Controls FEC
by puniverse- Replies
- 12
- Views
- 1,130
I had a few fec's do that to me. If you have cct...
I had a few fec's do that to me. If you have cct try to upload with the btcvt from the fc port first. if it fails there is an SA rj11 jack underneath and it is kind of hidden. Try to upload and...
-
06-10-2011, 10:55 PM
- Replies
- 12
- Views
- 1,597
99.9999 percent of the time, if you have problems...
99.9999 percent of the time, if you have problems with adaptive tuning. You have your pid processor set up wrong. Double check it. And now with cct 5.0 in the help there is a pid processor that tells...
-
06-09-2011, 09:26 PM
Thread: LonWatcher 2.33
by puniverse- Replies
- 9
- Views
- 1,726
I found the fix to error Could not listen on...
I found the fix to error Could not listen on poet/tcp: the address specified is already in use (-2532)
got to start then run and type cmd
type netstat -ano
look for port 6001 or 6002
... -
06-09-2011, 08:43 PM
Thread: Anybody got Alerton manuals?
by puniverse- Replies
- 14
- Views
- 1,578
You make it sound simple enough but I still have...
You make it sound simple enough but I still have a few questions. I finally got to see the system today and gathered some info. The front end is BACtalk for Windows v3.11. The controller completely...
-
06-09-2011, 09:47 AM
Thread: Anybody got Alerton manuals?
by puniverse- Replies
- 14
- Views
- 1,578
[QUOTE=puniverse;10408962]I would also like some...
[QUOTE=puniverse;10408962]I would also like some information. I had a bacTalk vav that failed on me and would like to know what software is actually needed to commission it. I was reading online and...
-
06-09-2011, 09:46 AM
Thread: Anybody got Alerton manuals?
by puniverse- Replies
- 14
- Views
- 1,578
I would also like some information. I had a...
I would also like some information. I had a bacTalk vav that failed on me and would like to know what software is actually needed to commission it. I was reading online and saw something about...
-
05-01-2011, 01:54 AM
Thread: Johnson Controls DX-9100
by puniverse- Replies
- 49
- Views
- 5,023
either buy an metasys NAE ( Network automated...
either buy an metasys NAE ( Network automated engine) which comes with UI so you can tie in through IP address. The other option is to use wmx9100 which is used mainly by technicians but is great...
-
01-07-2011, 02:41 AM
Thread: Trane BCI-I BACnet MS/TP for Intelipak
by puniverse- Replies
- 29
- Views
- 4,351
I seriously need help with this bci on three...
I seriously need help with this bci on three trane intellipaks....i discovered them in metasys extended architecture after spending countless hours to find out that Trane techs set the baud to...
-
03-31-2010, 01:46 PM
- Replies
- 7
- Views
- 558
i upgraded 4.1.2 to 5.0 yesterday. got called...
i upgraded 4.1.2 to 5.0 yesterday. got called back out this morning that all nae's keep going offline online bout every 10 min.... IE8 did work but was not recommended by milwaukee. 5.0 runs java...
-
08-26-2008, 06:51 PM
Thread: need edumacation....
by puniverse- Replies
- 1
- Views
- 246
need edumacation....
I want to learn a little bit more about ddc and other controls.... anyone know any good websites or where to get good documents, or classes that are worth taking in so cal.....
-
08-26-2008, 06:40 PM
Thread: Alerton, Envision display
by puniverse- Replies
- 4
- Views
- 831
can u email that to me.... please......
can u email that to me.... please... dblindsk8@msn.com im workin on an evision bactalk and cant figure out how to open the humidifiers manually....their not opening... just stay at 0% open...
-
lagotek sounds good.... but i rather hardwire any...
lagotek sounds good.... but i rather hardwire any websites that show what different kinds of wire to run
in a new house.... -
home auto
ok so heres the scope of work.... Im rebuilding my house and the framing is just starting to go up so im trying to gather some ideas from a good home automation system.... im running all the cable...
-
08-13-2008, 04:24 PM
Thread: need some ideas
by puniverse- Replies
- 0
- Views
- 194
need some ideas
ok so heres the scope of work.... Im rebuilding my house and the framing is just starting to go up so im trying to gather some ideas from a good home automation system.... im running all the cable...
Results 1 to 20 of 20