Search:

Type: Posts; User: black_syphilis

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    6
    Views
    284

    Looking for ultrasonic flow meter

    Hi guys,

    I'm looking for a ultrasonic flow meter (BACnet or modbus or pulse) for a 3'' piping.
    Budget and delay are tight.

    Thanks.
  2. Replies
    29
    Views
    1,027

    Try to reset your Jace. Connect your PC to Jace...

    Try to reset your Jace.
    Connect your PC to Jace through Shell mode and select Reboot
    During boot, a message will appear like:
    Press any key to restore factory defaults
  3. Replies
    29
    Views
    1,027

    And What is your workbench and Jace 7 version ?

    And What is your workbench and Jace 7 version ?
  4. Replies
    29
    Views
    1,027

    Your error window when you try to enter in your...

    Your error window when you try to enter in your platform like this

    http://img11.hostingpics.net/pics/186798ScreenShot362.png
  5. Replies
    29
    Views
    1,027

    Can you send Details from error window

    Can you send Details from error window
  6. Allen Bradley Micro850 Modbus Error

    Hi all,

    I have a AB Micro 850 and I want transfer data in modbus TCP but I have an error on my MSG_MODBUS2 module

    ErrorID 33 (A bad MSG file parameter exists)
    SubErrorID 37 (???)

    Anyone...
  7. Replies
    4
    Views
    281

    No first installation and no message to create...

    No first installation and no message to create user
  8. Replies
    4
    Views
    281

    KMC BACstage Password

    Hi,

    I installed KMC BACstage. What is the Master Operator Name/Password??

    Regards.
  9. Replies
    0
    Views
    215

    FX7 Memory glitch

    Hi all,

    I have a FX-7 with BACnet network (23 Devices (Alerton VAV), 20 pts each), 2x N2 Network (30 Devices each (VMA), 20 pts each).

    The problem is sometime I lost station (reboot).

    I...
  10. Replies
    18
    Views
    1,438

    The building is 25 years old. I will purpose an...

    The building is 25 years old. I will purpose an air balancing.



    Yes I think I can add one static pressure for each floors, I will move the pressure sensor on 2/3 of duct. Why do you see wild...
  11. Replies
    18
    Views
    1,438

    We want centralize all tenant room, among other...

    We want centralize all tenant room, among other things, for high and low temperature watch.




    Good point. But what can I do with my chiller if I slowdown the VFD?

    It's a chiller Trane RTWD...
  12. Replies
    18
    Views
    1,438

    Can you to be most clear in your explaining? I...

    Can you to be most clear in your explaining?

    I have a boiler and chiller system.
    I calculated energy saving and If I stop the AHU systems all the night, I save $20,000.00 by year. I will paid my...
  13. Replies
    18
    Views
    1,438

    Dual Duct + VFD

    Hi All,

    I have a building 6 Floors with 2 HUA (Perimeter: Cooling Only; Interior: Dual Duct).
    I want stop the units during the night and weekend but sometime there are some tenants on some floor...
  14. Replies
    6
    Views
    554

    There is not DDC, just 4 stages command. The...

    There is not DDC, just 4 stages command.
    The quoting is $ for add Tekmar indoor/outdoor controller.

    Suppose to maximize the performance of the boiler and establish savings on gaz consumption
  15. Replies
    6
    Views
    554

    No, Raypak is existing

    No, Raypak is existing
  16. Replies
    6
    Views
    554

    Raypak Controller

    Hi all,

    I have a boiler Raypak model H9-2342B, the DDC control the 4 stages. A contractor recommend me to install a boiler controller like Tekmar Indoor/Outdoor, 4 stages. What you think about...
  17. Replies
    44
    Views
    5,685

    30P is correct but so so compare FG series

    30P is correct but so so compare FG series
  18. I'm bashing some Alerton products because it's...

    I'm bashing some Alerton products because it's right. I don't want educate you, but please shows me I wrong about some Alerton products, I'm listening :pop:
  19. Replies
    44
    Views
    5,685

    First Trend controls IQ3 ( I'm sentimental ) ...

    First Trend controls IQ3 ( I'm sentimental )

    Second EASY IO FG <-- ****ing great product, don't forget to vote for him #ControlTrendsAward
  20. Why alerton products are not the best?

    Why alerton products are not the best?

    - Old programming software and Visio plugin
    - Programming not really user friendly
    - Envision is obsolete
    - Webtalk is a joke
    - BCM-WEB can make Ice...
  21. Replies
    9
    Views
    1,520

    Sure, what is your problem?

    Sure, what is your problem?
  22. Replies
    10
    Views
    1,303

    What is the link between the BACnet user with...

    What is the link between the BACnet user with write permissions and the other BACnet software?
  23. Replies
    9
    Views
    1,520

    It's not an obligation to take the 6000 course...

    It's not an obligation to take the 6000 course for buy 963. For you information, 963 is very easy!
    Don't hesitate to contact me by email (In my profil) if you need help or 963 example :putergreet:
  24. Replies
    10
    Views
    1,303

    Bad day! I integrated my modbus Thermopump to...

    Bad day!

    I integrated my modbus Thermopump to BACnet MSTP, I can read all my BACnet point BUT I can't write on them with third software (Bacstage / Metasys / Orcaview), it's said like Write...
  25. Replies
    10
    Views
    1,303

    [QUOTE=noskilltech;14675321]You do not need a...

    [QUOTE=noskilltech;14675321]You do not need a link when you export a point in the Bacnet Export Manager. You just discover the points you want to export and give them an AV or BV number.

    Oh yeah...
Results 1 to 25 of 35
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event