  1. Replies
    23
    Views
    1,153

    if the holes in ducts were on return duct, it...

    if the holes in ducts were on return duct, it would put the crawl area in a negative pressure and air would leak in from outdoors or upstairs. Air could even leak in from attic if chimney or pipes...
  2. Replies
    23
    Views
    1,153

    was going to say above as well, water could be...

    was going to say above as well, water could be getting in due to poor drainage around house.



    also, if was return, would be pulling in great deal of humidity laden air from outside,


    ...
  3. Replies
    24
    Views
    1,050

    is this the sort of thing op meant? ...

    is this the sort of thing op meant?

    http://hvac-talk.com/vbb/showthread.php?1533201-Capacitor-Replacement
  4. Replies
    13
    Views
    501

    years ago I used to use dry bulb probe w/ wet tp...

    years ago I used to use dry bulb probe w/ wet tp on it to get wb temps. put in return duct until stabilized. Trane had their charts for pistons set in wb temps.

    Then I got a Cooper temp analyzer...
  5. Replies
    24
    Views
    1,050

    I recall one DIYer posted on a capacitor for his...

    I recall one DIYer posted on a capacitor for his unit. information given did appear to be intended to mislead and even to point of damaging unit if followed.

    I have to agree if don't like DIY...
  6. From past experience, I believe Trane is much...

    From past experience, I believe Trane is much less likely to let their hi seer stuff be sold outside the approved sales channels.

    They want high seer stuff sold only as installed system. In my...
  7. Replies
    37
    Views
    720

    Was it working properly after repair, then...

    Was it working properly after repair, then started to act up? if so, I would guess motor shorted to ground internally first, elsewhere second.

    have seen condensor motors do this.

    as far as...
  8. Replies
    20
    Views
    594

    sharp as a bowling ball dumb as a box of rocks...

    sharp as a bowling ball

    dumb as a box of rocks

    if brains were dynamite, couldn't blow his own nose
  9. my two stage furnace has 5 different speeds, 2 in...

    my two stage furnace has 5 different speeds, 2 in ht, 2 cool speed, and fan only is 1/2 high cool speed.

    some var spd units have a ramping profle in cooling mode.
  10. by reading esp, you can switch filters and not...

    by reading esp, you can switch filters and not have to reset the manometer each time, since it will be reading airflow across blower.

    The var speed blower does make it a bit more tricky to track...
  11. you don't have to light a match....

    you don't have to light a match....
  12. you can put a dwyer mark III incline manometer on...

    you can put a dwyer mark III incline manometer on it and read pressure on the furnace. If its a single speed furnace, would need to set the esp (external static pressure) range that would be getting...
  13. Replies
    19
    Views
    1,817

    never considered using foam tape to bulk one up....

    never considered using foam tape to bulk one up. just keep hanging/plumbers strap on truck and use that in place of oem strap if doesn't fit old new capacitor. I like to leave a little long on case...
  14. Replies
    39
    Views
    1,391

    watching, for now

    watching, for now
  15. Replies
    20
    Views
    1,438

    'HVAC PAL' is gonna come get you...

    'HVAC PAL' is gonna come get you...
  16. Replies
    7
    Views
    339

    started w/ finish generator install. replace...

    started w/ finish generator install. replace pilot assy on new gas log set, factory issue

    continue work on wiring up building

    run some service calls

    rewire stack of trouffers for two corcuit...
  17. I don't want to give any of my info since I don't...

    I don't want to give any of my info since I don't trust people to keep it safe. They're not going to call and offer to pay costs if they screw up, right?

    I asked about an aircard at one of the...
  18. Replies
    22
    Views
    1,256

    use high speed tap for cooling I only add a...

    use high speed tap for cooling

    I only add a draft regulator if the furnace needs it
  19. Replies
    19
    Views
    1,817

    cozy capacitor

    "sleeve adapter" to adjust the strap fit. well, if they didn't like being cold would be nice.
    DSCN3906.jpg
  20. Replies
    17
    Views
    424

    the drone sounds like a guided torpedo, as...

    the drone sounds like a guided torpedo, as opposed to guided missile for air.
  21. black top, red base? much louder than lg pumps.

    black top, red base? much louder than lg pumps.
  22. Replies
    17
    Views
    424

    I was surprised to hear from a customer in nuke...

    I was surprised to hear from a customer in nuke tech that there are smaller ships now going to nuclear. thought the destroyers and frigates were all gas turbine now.
  23. noisy to me

    noisy to me
  24. Replies
    38
    Views
    1,408

    every time I work on a condensor now, I look for...

    every time I work on a condensor now, I look for any rubbing tubes. pretty common to see something rubbing, so I look and strap up/separate tubes/wires to prevent a failure.
    even had a few evap...
  25. Replies
    38
    Views
    1,408

    I've had a few under warranty, and one that...

    I've had a few under warranty, and one that wasn't.

    first was out of warr, cust still wanted to try. did acid away, triple evac, sl and liq l d/fs. ran great for 6 hrs then txv died.

    had two...