Search:

Type: Posts; User: david222

Search: Search took 0.00 seconds.

  1. Replies
    2
    Views
    523

    JCI CCT programming/training

    I have just opened up the CCT software and quickly decided to look for help. I have been programing DX9100 and using HVACPRO. But this CCT likes foreign no ladder logic etc. Can someone suggest some...
  2. Replies
    6
    Views
    1,888

    NECC in phili Pa (neccdelivers.com) has a cd with...

    NECC in phili Pa (neccdelivers.com) has a cd with the all of the software necessary. Ask for Auggie I deal with him there.
  3. Replies
    7
    Views
    1,031

    Thanks South central Va. NC state line

    Thanks

    South central Va. NC state line
  4. Replies
    7
    Views
    1,031

    Applied for Commercial service tech in danville,...

    Applied for Commercial service tech in danville, va
  5. Replies
    7
    Views
    1,031

    Freezemiser I did not realize they are in PA....

    Freezemiser
    I did not realize they are in PA. Thanks for answering. What do you do for CW?
    I have applied for a position with them and just trying to find out how they are to work for. Any input?
    ...
  6. Replies
    7
    Views
    1,031

    Colonial Webb Contractor

    I am trying to find out some info. on Colonial Webb Mechanical. They are located in the east. Is any one familiar with them from an employee perspective?
  7. Replies
    2
    Views
    446

    Thanks simux I went over the literature enclosed...

    Thanks simux
    I went over the literature enclosed with the pxp was not much help?
  8. Replies
    2
    Views
    446

    JC PXP setup question

    Does anyone have a simple step by step guide on how to set up a JC pxp?
    The pxp is tied to a DX9100. I have put the key in the 9100 an have figured out how to run the setting up to 100% and down to...
  9. Replies
    1
    Views
    800

    Johnson Metasys Training

    Looking for some advice/suggestions on getting traing on metasys.

    Thanks
    David
  10. Replies
    25
    Views
    1,597

    New condensing unit has no reciever and it is a...

    New condensing unit has no reciever and it is a cap tube. I started out with 12oz suction ran almost in a vacum. I have no superheat chart for this unit with 134. I thought suction should be around...
  11. Replies
    25
    Views
    1,597

    Thanks for all the suggestions. Got it running...

    Thanks for all the suggestions. Got it running seems ok 25# suction(maybe little high?), 140#head. Maintaining about 37* Only thing that supprised me called for 12oz when it was an R12 machine. Took...
  12. Replies
    25
    Views
    1,597

    model is Rht 1-32 wut s#34195. I have a new 134a...

    model is Rht 1-32 wut s#34195. I have a new 134a condensing unit i am installing.
    Thanks in advance
  13. Replies
    25
    Views
    1,597

    Converting to 134a

    I am converting a Traulsen commercial reach-in upright refrigerator (r12) cap tube metering, to 134a. Wondering how to charge? superheat?, weight? No superheat chart? Do not know how much r12 it...
Results 1 to 13 of 13