  1. Paladin

    I guest it's as easy as pie!! Our electrians give us a Paladin tool which worked? And go figure it's a Time Design Reflectometer.
  2. Diasychain

    Good day to all.

    Thanks for the insight. To add onto this, we would disconnect every daisychain connections to the controllers. Then we need to get the distance between each controller and then...
  3. Tool to read the distance of a 2,3 or 4 wire cable.

    Hello,

    I'm looking for a device which willl allow us to read a 2, 3 or 4 wire daisychain communication run.

    We tried a $18K Fluke network tool and didn't like the daisychain. What would be...
  4. Are you using the fieldserver tools on your PC??...

    Are you using the fieldserver tools on your PC?? if not get these from the web and run the Remote User Interface program.

    Are you sure the IP in the fieldserver is correct? what is the sub and...
  5. N2

    Power cycle the working DX9100 and see what version it is. Then power cycle the effected one and check this version.

    Do you have any other TC9102 that are on the network that is not causing this...
  6. Replies
    0
    Views
    95

    JCI LCT Logic - how to create a COS

    Hello,

    In the NAE LCT logic program, I need to active a horn from an input to output. Pretty simple, but I would like to use a COS, so once the latch is reset it won't be triggered again - unless...
  7. Replies
    3
    Views
    157

    Hello, The hotdog looking object has nothing...

    Hello,

    The hotdog looking object has nothing in it for the on/off times. I'm not at the site, but remember that beside the BV object for the default it has a statement saying that if BACnet...
  8. Replies
    3
    Views
    157

    ALC Priority Array

    Hello,

    We have logic program which causes a priority level of 6 (min on/off) if we change the default from Off to on. We don't have anything writing to this at that level and figure it's something...
  9. Replies
    6
    Views
    282

    YUP all 8 PLC's are used up - using all the PLC...

    YUP all 8 PLC's are used up - using all the PLC blocks for a operator lite panel and horns.

    The other option I have is to wrtie logic in the NAE to do the latching, and control the outputs...
  10. Replies
    6
    Views
    282

    Is this the part I don't fully understand. In the...

    Is this the part I don't fully understand. In the PLC, I used a SET command. So when the input goes on it latches this on. The only way to reset this is with the RST command. I don't have room in the...
  11. Replies
    6
    Views
    282

    DX9100 PLC Reset - Expert help needed!

    Hello,

    I have a JCI program with PLC logic that is using a SET command to keep on a lite. That's fine, but I need to Reset this from a NAE and not from the RST in the PLC.

    Is their any JCI...
  12. Replies
    17
    Views
    772

    Thanks - didn't know that.

    Thanks - didn't know that.
  13. Replies
    17
    Views
    772

    Touch Screen

    Hello,

    So time ago, someone had put on this forum a spead sheet on testing several different touch screen panels. I search but couldn't located it.

    Does anyone know were this baby is.

    Thanks
  14. Replies
    4
    Views
    252

    We didn't send any reload command. Once we put a...

    We didn't send any reload command. Once we put a new field controller on the Acrnet, it wants to download all the field controllers for ALL branches (routers).

    We checked teh BBMD and they are...
  15. Replies
    4
    Views
    252

    ALC WebCrtl V6.0 download Question

    Hello,

    We have several routers with around 30 field controllers connected. When we add in another field controller to one router, it tells us to download all the controllers? What I find odd, why...
  16. Replies
    2
    Views
    236

    Hello, The problem turned out to be with IT...

    Hello,

    The problem turned out to be with IT security. Once they opened the ports, everthing is fine.
  17. Hello, We are changing our BMS from Honeywell...

    Hello,

    We are changing our BMS from Honeywell to ABB. The output module that we use from the ABB is only 24VDC. Since most items are 3 wire (share common) we would create a problem with using...
  18. BAPI

    Hello,
    In our OR this is what we did - replaced the JCI stat with a BAPI that output 0-10 for the temperature range and 0-10 for the adjust.
    Then reprogram the controller to accept the 0-10, and...
  19. Yes - the damper actuator is for a VAV app. I did...

    Yes - the damper actuator is for a VAV app. I did find Belimo NMBx24-SR- which might work.

    As for the heating valve, the one we are replacing is the Honeywell M6410A to a version that is 24VDC...
  20. 24VDC powered Damper and Valve Actuator

    Hello,

    I looked around the web and can't really find what I need, looking for suggestions. We are looking for a valve actuator which is powered by 24VDC and outputs 0\2-10VDC. The only one we can...
  21. Replies
    4
    Views
    326

    Hello, I've done several jobs with fieldserver...

    Hello,

    I've done several jobs with fieldserver (JCI N2\MSTP to OPC, modbus, MSTP) and the only thing which I have to input, is the work that is requried on the configuration file.

    They always...
  22. Replies
    2
    Views
    236

    JCI N30 Site Manager HELP

    Hello,

    I installed System Tools 5.4 on a vitual XP Machine for the N30. The install when fine, no errors but when I try to run the Site Manager to connect to the N30 via ethernet, it gives me the...
  23. Mult Digital Inputs to one Analog Output

    Hello,

    Does anyone know of a device which will accept mult digital inputs and convert this to a single analog outout. So for example if we have 4 digital inputs, the analog output would be...
  24. Replies
    5
    Views
    251

    MAMAC System

    We need to send out the alarm message via ethernet. The sensaphone only uses the phone line.

    Thanks
  25. Replies
    5
    Views
    251

    Dialer to the internet

    Hello,

    We are looking for a unit that on alarm (dry contact ) will send out a alarm message using the internet to a blackberry or tablet etc.

    Thanks