  1. there is an interface module that will make the...

    there is an interface module that will make the icomfort work with the g71 you wont have all the diagnostics that the icomfort offers but will give you all the control of the stat from remote...
  2. Replies
    17
    Views
    626

    we have taken over the warranties for a few...

    we have taken over the warranties for a few dealers that lennox axed due to installation standards not being up help, as far as sales quotas ive never had anyone say anything about us meeting or...
  3. Replies
    17
    Views
    626

    A "Dave Lennox Premier Dealer" has to go thru...

    A "Dave Lennox Premier Dealer" has to go thru more to become that status of a dealer. The factory stays in close contact with the dealers customers, asking questions to insure that the dealer is...
  4. Replies
    8
    Views
    456

    since its isn't a "dedicated" supply(as in its...

    since its isn't a "dedicated" supply(as in its brought to the site and stored) and has to be pressure regulated there, more regulators and such to break down, more prone to moisture issues due to...
  5. Replies
    3
    Views
    209

    I believe there is a temp thermistor on the...

    I believe there is a temp thermistor on the outdoor unit that sends that info back to the stat, you do have to have 4 wire to the tstat and the outdoor unit, I do know that it will use the...
  6. Replies
    3
    Views
    209

    as long as its 4 wire and 18 gauge, it shouldn't...

    as long as its 4 wire and 18 gauge, it shouldn't be a problem
  7. ive worked on a bunch of these machines, found...

    ive worked on a bunch of these machines, found the same thing each time, the screen before the orfice plugged with a white plastic shaving like substance,
  8. Replies
    2
    Views
    244

    so thats how they are able to say so many...

    so thats how they are able to say so many millions are signing up, you dupilcate each person that actually gets on to do anything.

    something else comes to mind, Ive been doing some thinking...
  9. Replies
    2
    Views
    244

    the gubment healthcare website

    So out of morbid curiosity, and the inability to sleep tonight, i went to healthcare dot gov and it let me on, so i started the app process (about a 3hr process) just to see what it offered, that...
  10. Replies
    14
    Views
    1,264

    its the complete system that will rate out, ...

    its the complete system that will rate out, furnace, coil and outdoor unit, make sure the ahri sheet has the model numbers of all your equipment on it, they yellow sticker is the most common...
  11. Replies
    11
    Views
    516

    it can be done, I have done it in the past, ...

    it can be done, I have done it in the past, make sure that the blower in the unit is rated for the btu output of the pump though, most MH air handlers will only have a 1200/1400 cfm blower...
  12. Replies
    3
    Views
    490

    should be an edit post link on the bottom of your...

    should be an edit post link on the bottom of your post beside the reply tab, if not, you can click on the triangle with exclamation point in it and that will flag your post and you can explain to...
  13. Replies
    3
    Views
    490

    First and foremost you will need to edit out the...

    First and foremost you will need to edit out the prices from your post, as they are a violation of the site rules,

    Second, I have never heard of that particular brand (napoleon) but I am south...
  14. Replies
    4
    Views
    357

    contact the testing agency you got it thru, give...

    contact the testing agency you got it thru, give them your social number and they will replace it, rses cost 10 for a replacemtn card , esco was 10 or 15 when i replaced mine
  15. emails offering assitance are also frowned upon, ...

    emails offering assitance are also frowned upon, one of the reasons is liablity, if i offer a suggestion, you electrocute your self and die while attempting the site owners and myself could be...
  16. i will ask though, did you or anyone else...

    i will ask though, did you or anyone else weed-eat the grass around the outdoor unit in the last few days or do you have a teething pup in the yard?
  17. its gonna be one of a couple of problems, sadly...

    its gonna be one of a couple of problems, sadly due to the no DYI rules of the site i highly doubt if anyone will tell you what they are or how to repair it, i can say though that it should be a...
  18. Replies
    7
    Views
    296

    there could also be a drain safety switch in the...

    there could also be a drain safety switch in the condensate pan or line that would shut it down that breaks power to the stat, the unit is powered but the stat isnt, sounds like a safety is...
  19. Replies
    0
    Views
    207

    welfare abuse

    I sent this email a few minutes ago to my congressional delegation, probably wont do any good but if felt good to vent:

    Mississippi Delagation:

    While in a local discount store earlier today i...
  20. Replies
    7
    Views
    296

    sounds as if the stat has went south on you, ...

    sounds as if the stat has went south on you, the light in the unit is telling you that the system has hi and low voltage, the only thing i would really reccomend is turning the power of to the...
  21. Replies
    8
    Views
    414

    it takes a 25 370 for the compressor, a 5 370...

    it takes a 25 370 for the compressor, a 5 370 for the fan it shows a part number for a 25/5 370 it its a dual and if it has a start cap with a potential relay it takes 145-175 330vac for the start
  22. Replies
    34
    Views
    2,104

    the system may just need tweaking, I would give...

    the system may just need tweaking, I would give them a call and give them a chance to make it right before placing a stop on the check, it could be something very simple that was over looked, if...
  23. Replies
    3
    Views
    310

    i talked with someone at fieldpiece about an hour...

    i talked with someone at fieldpiece about an hour ago, and they fixed me right up, FIELDPIECE IS NUMBER ONE IN CUSTOMER SERVICE, in my opinion
  24. Replies
    3
    Views
    310

    !!!HEY FIELDPIECE DUDE!!!!!

    I cant remember the fieldpiece guys user name, but I am needing a battery cover and screw for my sc76, could anyone help me get in touch with him so I can get a part number for it so I can order one...
  25. Replies
    7
    Views
    450

    i tried one time, never could get it to stick or...

    i tried one time, never could get it to stick or seal, ended up ordering a new king valve and replacing it and the part of the line set attached to it,