Search:

Type: Posts; User: tmoss

Page 1 of 4 1 2 3 4

Search: Search took 0.00 seconds.

  1. Replies
    3
    Views
    584

    Read the user's information guide. It can be...

    Read the user's information guide. It can be found online. It tells you how to set the elapsed time, among other things. I set mine based on the frequency of cleaning my F300 on another system. For...
  2. Thread: Trane XL20I

    by tmoss
    Replies
    31
    Views
    6,071

    This may be a dumb question. What would be the...

    This may be a dumb question. What would be the benefit to spend big $$$ on a 20i system that does not have a communicating air handler/furnace? Lower kw usage? I didn't realize such equipment...
  3. Replies
    30
    Views
    17,049

    GlobalEX, I had a 20i installed in Feb, no...

    GlobalEX,
    I had a 20i installed in Feb, no issues. Local dealer in-house rebate and fed and local utility rebates dropped the price to the same as a 14i. I really wanted a system that could drop...
  4. Replies
    22
    Views
    12,793

    I thought only a few wouldn't meet it. I...

    I thought only a few wouldn't meet it. I certainly wouldn't buy one if I couldn't get the credit. Is it primarily the larger systems?
  5. Replies
    22
    Views
    12,793

    How big and how many returns do you currently...

    How big and how many returns do you currently have? If I'm not mistaken I think 150 square inches of net free area/ton is recommended. This is not the same as grill sizes. Even if your return ducts...
  6. Replies
    22
    Views
    12,793

    Th3, A 20i should qualify for the $1500 federal...

    Th3,
    A 20i should qualify for the $1500 federal tax credit, which should all but eliminate the 20% price diff on the 16i. Additionally, your local utility may have a rebate on qualifying high...
  7. Replies
    22
    Views
    12,793

    It depends. You may get a bigger rebate from...

    It depends. You may get a bigger rebate from Trane/feds/local uitility if going w/the 20i; which would bring the price delta down, and result in permanently lower kw usage than running a larger...
  8. Replies
    14
    Views
    5,215

    I stand corrected! I think. My current settings...

    I stand corrected! I think. My current settings of 400/ton and ISU 182 @ 50% and ISU 387 at 80% equals 160 cfm on a call to dehu. At least this is how I understand it to work. I welcome...
  9. Replies
    14
    Views
    5,215

    I just had a 20i installed with the TCON900 stat....

    I just had a 20i installed with the TCON900 stat. It does not need an EIM and only uses 3 wires to furnace board . It has two types of humidity control, one I believe is the standard IAQ control...
  10. Replies
    32
    Views
    1,829

    It is a sad time to be growing up. And no,...

    It is a sad time to be growing up. And no, JonDeere, I don't have 22 kids. I adopted two step-children and the Good Lord blessed us with a daughter and twins when the all-knowing doctors said we'd...
  11. Replies
    32
    Views
    1,829

    JonDeere Quote: Originally Posted by gary_g ...

    JonDeere Quote:
    Originally Posted by gary_g
    25%? Why stop there?

    I just threw a number out there

    What I think it will probably end up being is, costing the HO a little more than the rebate...
  12. Replies
    32
    Views
    1,829

    JonDeere, Are you a HVAC contractor? I'm just...

    JonDeere,
    Are you a HVAC contractor? I'm just trying to understand why having a higher tax credit for HO's means automatically charging them more.
  13. Replies
    5
    Views
    636

    Is the TCON900 a Trane branded IAQ?

    Is the TCON900 a Trane branded IAQ?
  14. Replies
    5
    Views
    636

    2 ton 20i equipment spec's, comments

    My oldest furnace has been condemned at 25 years old. I've decided to take this opportunity to replace the whole system. I already have a 19i and am very happy with it. One of the local Trane...
  15. Replies
    12
    Views
    1,339

    :) I'm with Beenthere's response. If it never...

    :) I'm with Beenthere's response. If it never cycles on 2nd stage then why have it? And if 1st stage holds setpoint on design day then isn't that stage's real world capacity equal to the load on...
  16. I have a F300 on one of my systems. Works great....

    I have a F300 on one of my systems. Works great. We noticed a decrease in dust in the areas it services. (Although it was part of a new system with original ductwork) I use cheap f/g for pre-filter...
  17. Replies
    11
    Views
    1,306

    You may have a negative pressure on the home...

    You may have a negative pressure on the home driving the higher OD humidity inside. I recently replaced my leaky single pane windows and am noticing greater comfort, ie less humidity, with minimal...
  18. Thread: Trane XL 19i

    by tmoss
    Replies
    22
    Views
    1,510

    I thought cph meant the maximum number of cycles...

    I thought cph meant the maximum number of cycles per hour, not the average. My vp 8k is set at 3 cph and it doesn't average that regardless of the load. At least I've never noticed that it does. ...
  19. Thread: Trane XL 19i

    by tmoss
    Replies
    22
    Views
    1,510

    The downsize to oversize is like Baldloonie said,...

    The downsize to oversize is like Baldloonie said, you paid a lot for single stage system. Price out the difference between a 5 ton single stage vs the xl 19i. What is the load on the home at...
  20. Thread: Trane XL 19i

    by tmoss
    Replies
    22
    Views
    1,510

    It's my understanding that the second stage...

    It's my understanding that the second stage should run near continuously at design temp, not the first stage. I would find out what design temp was used for your system and verify the dip switches...
  21. Replies
    24
    Views
    2,804

    Tigerdunes, You mean none of this link is true? ...

    Tigerdunes,
    You mean none of this link is true? According to it, many 19i's qualify.
    https://www.mytranecontrols.com/Residential/Downloads/Trane%20Central%20Air%20Conditioners.pdf
  22. Replies
    24
    Views
    2,804

    Don't forget the Trane rebate. 1K on a system...

    Don't forget the Trane rebate. 1K on a system I'm looking at that makes the 19i very cost competitive with the 14i. You've got to use a Trane stat but chances are adjusting your dip switches will...
  23. Replies
    39
    Views
    6,021

    If this were my only unit it would have been...

    If this were my only unit it would have been history 3 years ago. However, it is one of three and is only 1.5T. Real world kw savings will never pay to replace it. As it is it might run 6-8 hrs/day...
  24. Replies
    39
    Views
    6,021

    When we bought our current home 3 years ago it...

    When we bought our current home 3 years ago it still had 3 working 1984 Ruud condensers with Rheem furnaces of the same vintage. We changed one by choice 2 years ago, one last year ago that shorted...
  25. Replies
    28
    Views
    2,889

    I had issues with a HD/Trane install. You can...

    I had issues with a HD/Trane install. You can read my thread. What saved my butt was that I charged it on my HD card and HD's policy is that you don't pay a dime until you're satisfied. Well, I...