Search:

Type: Posts; User: T&C_Mechanical

Search: Search took 0.02 seconds.

  1. Steer clear of the SMAN3. Too many troubles with...

    Steer clear of the SMAN3. Too many troubles with mine.
  2. Replies
    15
    Views
    1,092

    This leak just might be the one that finally...

    This leak just might be the one that finally gives Al Gore skin cancer. LMAO.
  3. Replies
    24
    Views
    2,722

    Have trouble with the yellow jacket low loss...

    Have trouble with the yellow jacket low loss hoses on service valves that do not have a valve core in them. When it happens I just. Switch over t o the ball valve hoses I have. It's rare to have it...
  4. Replies
    11
    Views
    1,514

    Nice repair I have 9 of those units on a...

    Nice repair I have 9 of those units on a steakhouse in town when I started to work on them only half of them worked at all and it was the biggest mess I had ever seen. But I have repaired coils on...
  5. Replies
    6
    Views
    1,345

    Sporlan valves are my love lol they are all I...

    Sporlan valves are my love lol they are all I use. So do you know what body style and the input and output sizes and internal or external balance and what color is on your power head also I do have...
  6. You can always install a smaller cond. unit on a...

    You can always install a smaller cond. unit on a bigger evap. Coil but never in reverse. Some people do just that use a 4-5 ton coil on a 3 ton unit and use a txv to claim the higher seer. John is...
  7. Replies
    10
    Views
    1,252

    Fieldpiece sc-170 here also no complaints it's...

    Fieldpiece sc-170 here also no complaints it's the only non fluke device I use the wife has a 170 also but rarely uses it. She is a believer in Fluke instruments she has and I also have a 289 multi...
  8. Replies
    8
    Views
    1,969

    So in cooling is the reversing valve energized...

    So in cooling is the reversing valve energized did you wire correctly. If so is txv receiving liquid or is it being bombarded with gas pockets (undercharge). Was it a new line set or was old set used...
  9. Bottom line. Look at evap mod number. It has 48...

    Bottom line. Look at evap mod number. It has 48 in it. Wait a second I think that's 48,000 btu that equals 4 tons of evap capacity. The condensing unit may have been smaller but you can tie a 4 ton...
  10. Replies
    47
    Views
    4,965

    Some outdoor service disconnects are made fuse...

    Some outdoor service disconnects are made fuse only and it depends on code and if it's residential or commercial units. And if the main distribution panel is single phase or 3 phase usually you will...
  11. Replies
    232
    Views
    52,158

    Sticky: Poll: Goodman only here also. Pricing is great and...

    Goodman only here also. Pricing is great and never ever ever have I had one problem with a warranty part. Not that I have had to do many at all. Filters are all Emerson valves are just better. Some...
  12. Replies
    2
    Views
    757

    All coils I have installed in the last few years...

    All coils I have installed in the last few years have been Goodman brand and was designed for 410 and 22 difference is piston size installed or txv it will be a TX3N4 for a 3 ton 410 system or TX3N2...
  13. Replies
    26
    Views
    3,408

    DRT. Dead Right There

    DRT. Dead Right There
  14. Replies
    204
    Views
    33,290

    Flashlights both me and the wife use in the field...

    Flashlights both me and the wife use in the field every day and yes we differ on a lot of things. But we both are religious when it comes to flashlights so here is the list in order of what is used...
  15. Replies
    319
    Views
    25,687

    SMAN3 still running strong after 1 year. We both...

    SMAN3 still running strong after 1 year. We both have one set of them. We clean them once a week regardless of amount of use. Granted we rely on our analog class 1 gauges 75% of the time. But they...
  16. Replies
    29
    Views
    3,475

    I've changed the blown fuse after checking system...

    I've changed the blown fuse after checking system out if everything was normal I would try my luck on the old fuses but if it happened again then I knew to completely check out the system. I have...
  17. So many things to add but I'm sure this depends...

    So many things to add but I'm sure this depends on what part of the country you are in but one of the first restraunts I ever started working for is a mexican restraunt. So if you ever think reading...
  18. Just decided to do it on my own.

    Thank god for my family most of them are master electricians but others are master of mechanical systems as I hold both of those titles. For the most part I'm consitered the quiet one. So I had money...
Results 1 to 18 of 18
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event