Search:

Type: Posts; User: top mechanic

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    3
    Views
    813

    All I can think of is that there should be four...

    All I can think of is that there should be four fuses there three for the motor and one for the circuit board, the circuit board fuse is the one to the right, is this the one thats blowing ? If it...
  2. Replies
    24
    Views
    2,292

    I pay 425 for progressive transitions, there is...

    I pay 425 for progressive transitions, there is one problem with transitions though, when walking in and out of a building it takes them a little time to adjust , so your a little in the dark when...
  3. Replies
    41
    Views
    3,540

    yeah , most of them are jerks from my experience....

    yeah , most of them are jerks from my experience. Better off working for jews than bigtime athletes.
  4. Replies
    24
    Views
    2,292

    I use transitons too, but I don't think they give...

    I use transitons too, but I don't think they give you the same UV protection.
  5. Replies
    108
    Views
    3,604

    Sometimes the conversations here are childish

    Sometimes the conversations here are childish
  6. Replies
    12
    Views
    1,137

    The length of the lineset seems more critical...

    The length of the lineset seems more critical here, JMO, his problems are being caused by the large volume of refreigerant migrating back to the unit from the liquid and the suction lines,
  7. Replies
    2
    Views
    1,947

    I need to know if there is any configuration that...

    I need to know if there is any configuration that needs to be done in order to use this device as a repeater only,I am under the assumption that it is a repeater right out of the box, and must be...
  8. Replies
    12
    Views
    1,137

    It sounds like the condenser is totaly full of...

    It sounds like the condenser is totaly full of liquid refrigerant when it starts, this will cause it to sound very bad and probably shake a little on start-up it may even trip the breaker or fuse...
  9. Replies
    54
    Views
    3,436

    John, Andy, Dow, our opinions are in complete...

    John, Andy, Dow, our opinions are in complete agreement with each other, My position is that yes the rule will always apply, but while a system is running the refrigerant is moving from state to...
  10. Replies
    54
    Views
    3,436

    So if I hasve a few bubbles in the sightglass...

    So if I hasve a few bubbles in the sightglass does it mean that I don't have any subcooled liquid ? This would have to be true if I follow the rule right ? The bottom line is that the rule only...
  11. Replies
    54
    Views
    3,436

    Well John and Dow, I give up , some here are...

    Well John and Dow, I give up , some here are trying to apply a rule to a receiver but won't apply it to any other part in the system, I find it amazing that they can't see the diference between a...
  12. Replies
    54
    Views
    3,436

    Like I said, there is refrigereant in every stage...

    Like I said, there is refrigereant in every stage in the receiver, if there wasn't there wouldn't be any work being done.
  13. Replies
    22
    Views
    1,190

    I just turned a 100,000 on my Ford 250, and have...

    I just turned a 100,000 on my Ford 250, and have only replaced the brakes, sure the paint on the bumper peeled off , but I don't need to paint to get me where I'm going.
  14. Replies
    54
    Views
    3,436

    Green, I read the thread you posted , in a...

    Green, I read the thread you posted , in a nutshell I think Dow said it best "its just a big can" and is being way overthought, is it satuated while in the receiver?

    Some of it is, same as in the...
  15. Replies
    28
    Views
    1,867

    I'm of the belief that there are not any major...

    I'm of the belief that there are not any major diferences in the abilities of the major control companies hardware. Wheter it be simple DDC over their own bus or LOn\Bacnet, the difference is really...
  16. Replies
    6
    Views
    1,454

    Its not really the overgreasing that kills them...

    Its not really the overgreasing that kills them its the pressure, so grease the bearing then pull the zirc fitting out and relieve the pressure, wipe it off , put it back in and you rdone.

    ...
  17. Replies
    27
    Views
    1,550

    I'm on cable but I use AOL bring your own access,

    I'm on cable but I use AOL bring your own access,
  18. Replies
    24
    Views
    1,551

    Hey, it was a joke. I don't know how to use the...

    Hey, it was a joke. I don't know how to use the smilies, they seem to be a little confusing here.It souds like he has a little Karpal Tunnel going on.
  19. Replies
    27
    Views
    1,550

    AOl. Where do you get more or better for 19.95 ?

    AOl. Where do you get more or better for 19.95 ?
  20. Replies
    24
    Views
    1,551

    There is no finger between your Ring and Middle...

    There is no finger between your Ring and Middle fingers, maybe thats why you can't feel it.
  21. Replies
    40
    Views
    2,892

    It does tfollow the fan law the law says, that...

    It does tfollow the fan law the law says, that HP varies as the cube of the RPM, and it does, that law has nothing to do with static, why does eveyone keep saying that it does, the words static...
  22. Not being micromanaged, especially by someone...

    Not being micromanaged, especially by someone that is less able.
  23. Replies
    54
    Views
    3,436

    A receiver gives thew system a lot of benefits,...

    A receiver gives thew system a lot of benefits, the expansion valve needs to see a column of liquid, I'll try to answer your questions about it.

    The residential systems not having it ?

    It would...
  24. Replies
    54
    Views
    3,436

    I wouldn't get hung up on receivers, they are...

    I wouldn't get hung up on receivers, they are just resovoirs to store excess subcooled liquid when the system doesn't need it,

    [Edited by top mechanic on 05-06-2005 at 05:37 PM]
  25. Replies
    31
    Views
    1,221

    Mark, I don't know your age but before...

    Mark,

    I don't know your age but before starting an exercise routine, I would get a physical. JMO,
Results 1 to 25 of 81
Page 1 of 4 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event