  1. what the

    I did not see any mention of replacing the furnace/blower is this correct? With a split system the blower, evaporator, condenser and metering device need to match. The thermostat is not your problem,...
  2. Replies
    15
    Views
    1,566

    Insist on a load calculation

    I have done countless load calculations and the one thing I have learned is I could not possibly eyeball the size unit for a home without over-sizing the equipment. I constantly put in smaller units...
  3. Replies
    5
    Views
    1,932

    Refrigerant?

    How long do you plan to be in the home?
    The real issue is not going to be any concern until your warranty is up in 5-10 years depending on what you are receiving. And your unit (R-22) has been...
  4. also waiting

    We were able to get our hands on a 24ANA760 and installed it yesterday. We are waiting on others but here May will be the first availability.
  5. Thread: charging

    by sayco bob
    Replies
    13
    Views
    1,351

    delta T?

    Precise Temperatures:
    What do you consider a proper delta t? Are you talking about the delta t for the evaporator, condenser, or both? Are you measuring dry bulb or wet bulb temperatures? If you are...
  6. Replies
    15
    Views
    1,607

    Thanks Loonie, I am familiar with why oversizing...

    Thanks Loonie, I am familiar with why oversizing is less efficient, unfortunately I installed a furnace for a customer last month. She had no complaints from her tenant after the installation but she...
  7. Replies
    15
    Views
    1,607

    Does anybody know where I can get some...

    Does anybody know where I can get some information that will help explain how oversizing a mid efficiency gas furnace will waste more energy than a properly sized unit? Thanks in advance for any help.
  8. Replies
    10
    Views
    1,064

    just my opinion

    I lived in Northern VA before moving to southern AZ six years ago. I think you should consider staying with an all electric heat pump or go to a duel fuel system.
    If you go duel fuel you will...
  9. Replies
    11
    Views
    937

    been a while

    I worked for Simpson heating and cooling when I was in VA. It has been 6 years so many changes have been done but they wera a solid company.
  10. duel fuel is the way to go

    I don’t know what your local utility rates are but I believe dual fuel is the way to go. Heat pumps often don’t have the same life as a gas furnace and A/C combination because of the extreme...
  11. Replies
    9
    Views
    1,496

    duel fuel

    Have you considered duel fuel? The Carrier Infinity is the best control I have seen for this. It uses indoor and outdoor temperatures as well as indoor humidity to determine what mode to run in as...
  12. Replies
    9
    Views
    1,496

    ????

    I read your last two posts and I wanted to reply with specific answers to your questions but I’m away from my office and could not give you answers until Monday. I have some questions for you The...
  13. Replies
    30
    Views
    2,706

    Oh NO

    Once again someone replaces a 20++ year old 3-Ton system with a 4-Ton System. Because “Bigger is Better”.
    As far as ratings between units make sure you are comparing apples to apples. Some...
  14. Replies
    6
    Views
    1,041

    where are you

    What part of the country are you in? I am in Tucson and we see “raised floor” returns with a single inlet quit often. I agree that a variable speed furnace (blower) will be quieter on the lower...
  15. Replies
    17
    Views
    1,539

    Lets see?

    Let’s see,
    Was the thirty three thousand + BTU’s that his load calculation based on total BTU’s or is that the figure that his program used to determine based on some percentage of the actual BTU’s...
  16. Replies
    0
    Views
    553

    I was wondering is anyone has installed any...

    I was wondering is anyone has installed any ductless heat pumps that use R-410a refrigerant. I have seen some ads for such units but I have only found one that is built in South Africa. I have a...
  17. Replies
    7
    Views
    1,156

    consider duel fuel

    I don't know where you live or what your utility rates are but where I live natural gas runs around $1.00 per therm and electricity runs just under $.10 per KW (winter rates are even lower). I am...
  18. vent termination

    I would also recommend that the vent termination be corrected. The reason for the 12" between the inlet and outlet is to prevent re-circulation of the exhaust into the intake. I think this is...
  19. Replies
    14
    Views
    2,830

    1" filters

    I would also stay away from the 1" filters. The Carrier Infinity control is a wonderful tool to learn about air flow. The communication between the control and blower allows us to see the CFM...
  20. Replies
    14
    Views
    2,830

    single stage v/s two stage

    Don’t get me wrong I believe in two-stage cooling when it fits the application. I just don’t think that the cost difference is always justified. If one system calls for a 3.5-ton unit and you have to...
  21. Replies
    14
    Views
    2,830

    Where in the AZ Desert are you?

    If you were not in Phoenix I would stay away from Lennox. Just my opinion but I am in Tucson and there are no Lennox distributors here. I can't begin to tell you what problems this arises from this!...
  22. Replies
    13
    Views
    8,615

    Cheaper Solution

    You can replace the Thermostat with a switch! That way you can cycle your oversized system that has an improper duct system when ever you want. P.S. Remember it takes @ 9 min. for your unit too reach...
  23. Replies
    22
    Views
    2,323

    R-401A vs R-22 / Irascible

    "The ONLY thing I like about 410A over 22 is that in some cases its higher density will allow you to run smaller refrigerant lines. And it’s also true that 410A is more finicky about installation...
  24. Replies
    24
    Views
    8,899

    As far as of I am aware Heil Does not make a...

    As far as of I am aware Heil Does not make a R-410A unit. How and why do you know that 5 ounces of oil was removed from your unit? A typical residential unit has a hermetic (sealed) compressor has no...
  25. Replies
    29
    Views
    9,008

    return duct ?

    I like the way they reduced the return duct before making a sharp 90 deg turn with no throat before entering the air cleaner. I suppose they did this to increase the velocity and so the lower half of...
  26. Thread: Coleman?

    by sayco bob
    Replies
    9
    Views
    1,874

    I have some great camping equipment by Coleman

    I have some great camping equipment by Coleman
  27. Replies
    27
    Views
    4,332

    Correct me if I'm wrong

    I believe the Goodman unit you are considering is a variable speed 80% AFUE unit. The Carrier is not variable speed. This will have an effect on the combined SEER rating. I'm not a big fan of Goodman...
  28. Replies
    58
    Views
    6,969

    Carrier Dealer

    Rick: was this a Factory Authorized Dealer? There are different requirements for becoming Factory Authorized. If so I am sorry to hear this. You certainly do not need to go thru Carrier to replace...
  29. Replies
    58
    Views
    6,969

    That's a shame

    Rick: you can pay now or pay later. If you don’t have the load calculations done the system will not work properly. Would you rather save a couple dollars now and not be happy with the system you...
  30. Replies
    4
    Views
    1,586

    sorry tinner

    I apologize for the d-i-y info. I misread Willie’s post. Thought he had installed the furnace. I agree you should call back the installing contractor. It should be under warranty if recently...
  31. Replies
    13
    Views
    4,353

    Did I misunderstand?

    how will an Aprilaire 5000 help control the humidity?
  32. Replies
    4
    Views
    1,586

    I am not familiar with thus model but this...

    I am not familiar with thus model but this problem is typical of the ignition control not sensing the flame. There is typically a flame sensing rod that will have a small dc micro amp current when a...
  33. Replies
    22
    Views
    5,717

    Here is a link for an energy savings calculator...

    Here is a link for an energy savings calculator from energy star. they also have a gas furnace and heat pump version. It is an excel spread sheet that you can copy to your hard...
  34. Replies
    22
    Views
    5,717

    the same story here

    I recently replaced my gas/electric split system with a duel fuel Infinity split for that reason. I looked at the fuel cost of both and determined this was my best solution. I couldn’t be happier...
  35. Replies
    16
    Views
    6,257

    this just happened to be on a building that I was...

    this just happened to be on a building that I was doing some work on. I talked to the store owner but he did not seem to care.
  36. is that metal tape wrapped around the connections

    is that metal tape wrapped around the connections
  37. Replies
    16
    Views
    6,257

    http://ww2.imagewiz.net/images/hvac/28165_P1010023...

    http://ww2.imagewiz.net/images/hvac/28165_P1010023.JPG


    if this picture does not load will someone tell me how to attach a JPG. Thanks


    --------------

    from Boss:
  38. Replies
    12
    Views
    4,566

    This is what happens when you get low bid work...

    This is what happens when you get low bid work done.http://ww2.imagewiz.net/images/hvac/28165_P1010023.JPG

    http://ww2.imagewiz.net/images/hvac/28168_P1010028.JPG

    I hope these pictures are...
  39. Replies
    4
    Views
    4,390

    I found this supply plenum and flue apart behind...

    I found this supply plenum and flue apart behind the drywall during a bid to replace the existing system that was a ton oversized and never worked very well. ...