Search:

Type: Posts; User: white6294

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. Replies
    14
    Views
    2,315

    "Call code enforcement" Yes!!! Before some...

    "Call code enforcement"
    Yes!!! Before some child gets wrapped up in that mess.
  2. Replies
    10
    Views
    4,066

    Insane, and where did they choose to install the...

    Insane, and where did they choose to install the blower assemble....?
  3. Thread: Stocks

    by white6294
    Replies
    56
    Views
    2,408

    There are way to many stocks for any of us to...

    There are way to many stocks for any of us to find the right ones, never mind know when to buy and when to sell. Thats why I am a firm believer of using a stock picker, I have been using...
  4. Replies
    18
    Views
    1,687

    refereker Writing and spelling is my weakest...

    refereker

    Writing and spelling is my weakest link and it is the subject of give the least of amount of time. English is my wifes second launguge and she proofreads my reports for school. My...
  5. Replies
    18
    Views
    1,687

    grewya20 The only thing these people will be...

    grewya20

    The only thing these people will be supervising is the fry station at McDonalds.

    I believe it, straight A's are not easy, I am in for my ME and mainting a 3.2 but a 4.0 is out of the...
  6. Replies
    6
    Views
    804

    servtech2 Ive recieded your resume and will...

    servtech2
    Ive recieded your resume and will deliver it to my boss in the morning. As for steady work, Ive worked here for 3 years and have only seen layoffs for work ethincs, never for lack of work.
  7. Replies
    6
    Views
    804

    The problem I see is that hardly any every...

    The problem I see is that hardly any every helper wants to learn, wants to earn more money, or wants to make any more effort in life then the bare min.

    As for becoming a leader, I cant teach...
  8. Replies
    6
    Views
    884

    Good question , I wish i had the answer

    Good question , I wish i had the answer
  9. Replies
    9
    Views
    1,100

    i am located in floridia and knock on wood it...

    i am located in floridia and knock on wood it seems like busniess as always. the company mathced our total from the year before and have some work lined up for next year. My boos spends lots on...
  10. Replies
    6
    Views
    804

    job opening sarasota floridia

    I work for a company that has been having bad luck finding professianal people through newspapers so i thouhgt this might be a good place to try finding some good applicants

    The company is looking...
  11. Thread: c/u pad?

    by white6294
    Replies
    6
    Views
    1,959

    c/u pad?

    http://img456.imageshack.us/img456/7154/photo0048op2.th.jpg
    http://img231.imageshack.us/img231/449/photo0049lr1.th.jpg
    yes, that is the origanol skid the trane c/u came with in the box, fully...
  12. Thread: static

    by white6294
    Replies
    3
    Views
    1,752

    yes it is the finished product, and the company...

    yes it is the finished product, and the company who installed it spent 14 hours trying to figure out why there was low capacity and high bills, total cfm for the 5 ton was 1247.
  13. Thread: static

    by white6294
    Replies
    3
    Views
    1,752

    static

    http://img504.imageshack.us/img504/4176/photo0062nx4.th.jpg
    http://img516.imageshack.us/img516/3208/photo0060ys2.th.jpg
    this is a brand new house, 5 ton unit with zoning, electric bill is 600, the...
  14. Thread: pmac

    by white6294
    Replies
    8
    Views
    1,244

    pmac

    http://img165.imageshack.us/img165/2039/photo0015mp6.th.jpg
    i dont think somebody cares about their job. i found this on un install check up.
  15. Replies
    5
    Views
    1,828

    junction box??

    http://img300.imageshack.us/img300/4892/photo0014mw4.th.jpg
    here is a classic that really alarms me, i cut this masterpeice out of an attic on a recent install, the wip made of 6awg for a 10kw was...
  16. Thread: air leak

    by white6294
    Replies
    0
    Views
    1,035

    air leak

    http://img249.imageshack.us/img249/9084/photo0028oh6.th.jpg
    installers decided it was best to metal tape the collar to the package unit and then screw 2' metal pipe to the collar. along with this...
  17. Replies
    18
    Views
    3,102

    with shipping was around 800, and does not come...

    with shipping was around 800, and does not come with manifold
    digi-cool dot com
  18. Replies
    18
    Views
    3,102

    i used a tif zx-1 electronic leak detector, the...

    i used a tif zx-1 electronic leak detector, the c/u was impacted, may have something to do with it, and the evap coil on a rheem, i am not surprised.

    orlanotech, i find the digi nice, there is no...
  19. Replies
    18
    Views
    3,102

    if it was just the c/u leaking we could have just...

    if it was just the c/u leaking we could have just changed that for around the same price, but the evap was leaking also, along with a bad t-stat. it was cheaper for her to replace with warranty then...
  20. Replies
    18
    Views
    3,102

    part for part

    brother-in-law advised lady to replace all her leaking a/c compents rather than buy a new one.
    http://img441.imageshack.us/img441/2442/photo001vu5.jpg

    i got my service manager out of the office...
  21. Replies
    24
    Views
    3,555

    i am in sw fl , i am nate cert., work as a tech,...

    i am in sw fl , i am nate cert., work as a tech, with 2 years experince in res, i work 45h a week, average $23.50 with commision.
  22. Replies
    29
    Views
    2,634

    sounds to me that the comp toke to much of a...

    sounds to me that the comp toke to much of a beating when the cu txv failed, a new comp would only get u to the next step of diagnostics, best go with new equipment.
  23. i am with heatpumpguru, a 3 ton 2 stage 16 seer...

    i am with heatpumpguru, a 3 ton 2 stage 16 seer would be your best choice, it would save more money over the 8-10 years you plan on staying, and would be in low stage most of the time, taking more...
  24. that car is very gay, but it would be funny if he...

    that car is very gay, but it would be funny if he happened to see it on the internet.
  25. Replies
    17
    Views
    2,979

    any of us could have done 100% better without...

    any of us could have done 100% better without even trying, i dunno the problem with some ppl but that looks like hell
  26. Thread: t-stat check

    by white6294
    Replies
    12
    Views
    3,058

    http://img241.imageshack.us/img241/4332/dsc00095ln...

    http://img241.imageshack.us/img241/4332/dsc00095ln2.jpg
  27. Replies
    13
    Views
    3,565

    now i see, i really thought it was painted. damn.

    now i see, i really thought it was painted. damn.
  28. Replies
    13
    Views
    3,565

    what were they thinking, i never seen one painted...

    what were they thinking, i never seen one painted so bad.
    is there something to take that paint off without damaging anything?
  29. Replies
    7
    Views
    2,545

    the rest of the ductwork is bigger, just the...

    the rest of the ductwork is bigger, just the ductwork coming threw the ceiling and the plenums are to small. i dunno why they let it happen like that, but i know i will be there first hot day when...
  30. Replies
    7
    Views
    2,545

    no its ductboard, but i am just not sure on the...

    no its ductboard, but i am just not sure on the angle.
  31. Replies
    7
    Views
    2,545

    http://img241.imageshack.us/img241/7144/victor007e...

    http://img241.imageshack.us/img241/7144/victor007ev5.jpg

    This is the supply plenum, the return is the same way. Do ya think it will work???
  32. Thread: bard

    by white6294
    Replies
    9
    Views
    3,173

    thoglow yeah it is residental, but thank god not...

    thoglow
    yeah it is residental, but thank god not a subdivision. it was once one house but they made it into a two apartment, so they retrovitted 2 bards, one on each side. and i didnt look at the...
  33. Thread: bard

    by white6294
    Replies
    9
    Views
    3,173

    http://img159.imageshack.us/img159/5976/bardug2.pn...

    http://img159.imageshack.us/img159/5976/bardug2.png
    http://img241.imageshack.us/img241/8027/bard3zh9.png

    for those of u that havent had the pleasure of working on a bard, the service panel is on...
  34. Replies
    56
    Views
    18,391

    imagine that bad weld in a/h in closet, on a...

    imagine that bad weld in a/h in closet, on a platform in the hallway.
  35. Replies
    0
    Views
    492

    i had a 4 zone control board carrier that is...

    i had a 4 zone control board carrier that is about ten years old, it had temp readings in every room, and one t-stat that controlled all of these zones, and the programs for these zones. i sold the...
  36. Replies
    1
    Views
    597

    i dont know if this is breaking forum rules, but...

    i dont know if this is breaking forum rules, but i am 30 minutes away working for kobie complete and my bosses prices are uassally pretty good, are installers are average but the best company from...
  37. Replies
    75
    Views
    5,717

    finding a company with techs that dont mind...

    finding a company with techs that dont mind sharing knowledge, it is hard to find but is worth looking for.
  38. sounds like u have your blue hose in the wrong...

    sounds like u have your blue hose in the wrong spot, try the service port closest to the reversing vale for a correct suction reading.
  39. Replies
    14
    Views
    1,884

    u would be knocking yourself out charging by any...

    u would be knocking yourself out charging by any given number for superheat on any chart given. the only chart u would be able to use is the chart that asks what the indoor wet bulb and dry bulb are,...
  40. Replies
    20
    Views
    1,699

    perhaps we should not give u a mark up, but then...

    perhaps we should not give u a mark up, but then give seprate bills for our training, tools, trucks, medical, dental, 401,nextels, gas,shop fees, office fees, truck repairs, repaiers of equipment,...
  41. Replies
    14
    Views
    1,884

    no matter what u do it wil never be right, i...

    no matter what u do it wil never be right, i would just charge by temp difference
  42. Replies
    17
    Views
    2,224

    i have folllowed carriers instructions before,...

    i have folllowed carriers instructions before, and after flushing the lines with rx11, the inside of the lines looked like they were brand new, but yes i do agree changing them would not hurt, and...
  43. Replies
    25
    Views
    4,880

    a perfect install would not be likely by...

    a perfect install would not be likely by engeeniring stand pionts as their are many different ways of doing things, some may appear pointless but imo they should all be considered. it is my practice...
  44. Replies
    8
    Views
    1,295

    it does sound like u need two systems, and i...

    it does sound like u need two systems, and i would not recomend a trane 19 seer anyways, with having 2 compresors for multistage if one burns out u will be stuck with the replacement cost of both....
  45. Thread: Lra rla fla

    by white6294
    Replies
    1
    Views
    983

    are there any exact percentages on how to compare...

    are there any exact percentages on how to compare the given nameplate readings against what the motors are actually pulling. i heard so many differnt things from ppl i work with, i am looking for...