Search:

Type: Posts; User: #1servicetech

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    11
    Views
    290

    I have tried comm 1 and comm 2 with cbus and I...

    I have tried comm 1 and comm 2 with cbus and I get the 32 error. there must be a driver missing or something else I need to do to get it to communicate.
  2. Replies
    11
    Views
    290

    This thing worked until the hard drive went bad....

    This thing worked until the hard drive went bad. the receive light is blinking even now. It has to be some kind of driver I am missing. I will try to reach someone who can give me an answer. This was...
  3. Replies
    11
    Views
    290

    There is another one. I will just click on the...

    There is another one. I will just click on the link and you will see it.

    https://customer.honeywell.com/en-US/pages/product.aspx?cat=HonECC%20Catalog&pid=14507549-001/U
  4. Replies
    11
    Views
    290

    It is a rs485 box that gets it's power from the...

    It is a rs485 box that gets it's power from the keyboard plug. The graphics are all there but will not work due to the com port problem.
  5. Replies
    11
    Views
    290

    I had all of that set up properly. the problem...

    I had all of that set up properly. the problem turned out to be that the version that was left on site was not what was in the old computer. I installed version 1.7.1 and it all came up fine. I...
  6. Replies
    11
    Views
    290

    Honeywell XBS

    I have a building that has the Honeywell XBS Program as a head end for a Honeywell excel 5000 system. The computer it was on lost the hard drive.
    I found an older computer and installed windows 98...
  7. Replies
    6
    Views
    395

    also, neither CCT nor SCT will work on a 64-bit...

    also, neither CCT nor SCT will work on a 64-bit computer.

    I am using CCT on a 64 bit windows 7 machine with no problems.
  8. Replies
    17
    Views
    766

    The ratio is 4 to 1. so if the prop band is 4 the...

    The ratio is 4 to 1. so if the prop band is 4 the integral is 1. I usually put a division block in and divide by 4 so that I just need to adjust the prop band.
  9. Replies
    7
    Views
    306

    By his description he has a reliatel board which...

    By his description he has a reliatel board which makes the cti obsolete.
  10. Replies
    7
    Views
    306

    The fact that it has a comm4 card is telling me...

    The fact that it has a comm4 card is telling me you have a tracer or tracker system there now. is there a problem with the system you have now?
  11. Replies
    3
    Views
    408

    I have done this myself. you need to give your...

    I have done this myself. you need to give your jace a static IP on your network. then you use port forwarding in your router and forward that address to port 80. you then need to either check your...
  12. The upgrade is easy to get. the part number is...

    The upgrade is easy to get. the part number is LP-FX40UPG-0 I got one off of ebay ( FX20 ) about a year ago and just upgraded it 2 weeks ago. I should add that you need workbench to do the upgrade.
  13. Thread: Lon Plug

    by #1servicetech
    Replies
    12
    Views
    694

    Just to let everyone know, I found the part at...

    Just to let everyone know, I found the part at mouser. the part number is 14310214402000 and is made by Harting. the picture shown is the wrong one t but the part is correct.
  14. Replies
    1
    Views
    184

    Carrier 6400 controller problem

    I have a xl23 chiller with a carrier 6400 controller. I uploaded the program and was going to make a few changes. when I tried to click on controller to look at the setup, it was greyed out and...
  15. Thread: Lon Plug

    by #1servicetech
    Replies
    12
    Views
    694

    I think I found it on Mouser. I will post the...

    I think I found it on Mouser. I will post the part number if it is right. I went to the site you book marked and there is a 27.00 surcharge to cover the minimum.
  16. Thread: Lon Plug

    by #1servicetech
    Replies
    12
    Views
    694

    Thanks for the numbers. both sites don't show...

    Thanks for the numbers. both sites don't show anything online so I will give them a call tomorrow.
  17. Replies
    5
    Views
    513

    I would just use a MUX to put the setpoint or...

    I would just use a MUX to put the setpoint or input to a value that would make the pid go to 0
  18. Thread: Lon Plug

    by #1servicetech
    Replies
    12
    Views
    694

    I went to both sites and put in the numbers that...

    I went to both sites and put in the numbers that are on the plug but there are so many. does anyone have a part number?
  19. Thread: Lon Plug

    by #1servicetech
    Replies
    12
    Views
    694

    Lon Plug

    I have the lon usb adapter. The plug is getting a little worn and I sometimes have to adjust it to get communication. does anyone know where I can get a new plug for this? I am talking about the...
  20. Replies
    16
    Views
    2,113

    without the original disk you probably won't be...

    without the original disk you probably won't be able to reinstall it. did you have graphics? if you did you may be able to save those.
  21. I just read a previous response and you said you...

    I just read a previous response and you said you have the old hard drive in the new computer. did you release the authorization code from the old computer and reregister it?
  22. Is there an address written anywhere on the bcu?...

    Is there an address written anywhere on the bcu? if this is bacnet IP the workstation will need to be in the same subnet address range to connect.
  23. Are you using a crossover cable? you need a...

    Are you using a crossover cable? you need a crossover cable for the computer to bcu connection.
  24. Replies
    5
    Views
    394

    Thank you. I will give this a try.

    Thank you. I will give this a try.
  25. Replies
    5
    Views
    394

    Trane BCI-R problem

    Good morning all.
    I have a trane BCI-R that is giving me problems. I have a jace installed with the mstp license and I can see all of the points fine. I turned on BO1 which is supposed to enable...
  26. Replies
    7
    Views
    419

    The PC

    The PC
  27. Replies
    7
    Views
    419

    I just rechecked and you are right on both counts.

    I just rechecked and you are right on both counts.
  28. Replies
    7
    Views
    419

    I thought that might be the case. I have switched...

    I thought that might be the case. I have switched it all to a laptop with a modem for now and will upgrade it all as soon as possible.
  29. Replies
    7
    Views
    419

    old alerton TUX

    I have an old alerton tux system. it has an ISA card in the old computer which has died. it says IBM Lan card and has only 2 wires to a 25 pin rs232 type connector. is this an RS485 card? can I use a...
  30. yes, you would need to set up a VPN or use log me...

    yes, you would need to set up a VPN or use log me in.
  31. yes, it will work fine on a 64 bit computer. I am...

    yes, it will work fine on a 64 bit computer. I am running version 17 on a 64 bit win7 computer currently and it all runs fine. as was said before, you need the latest service packs.
  32. Replies
    1
    Views
    283

    Staefa Jace

    Does anyone have the staefa jace default platform password?
  33. Replies
    1
    Views
    375

    How are you starting them up? are you using the...

    How are you starting them up? are you using the run*.bat for them?
  34. Replies
    9
    Views
    1,372

    Could I get a copy of that also please?

    Could I get a copy of that also please?
  35. Replies
    3
    Views
    378

    If I remember correctly it would give you the...

    If I remember correctly it would give you the name and ask if you still want to log in using that name. have you gone into the setup and put the correct port number and baud rate? at the first screen...
  36. Replies
    3
    Views
    378

    Are you using PCLedit or PCMedit? what kind of...

    Are you using PCLedit or PCMedit? what kind of computer comm port are you using?
  37. Replies
    4
    Views
    452

    The baud rate could actually be anything. it is...

    The baud rate could actually be anything. it is changeable. I would try 1200 first then try the others.
  38. Replies
    4
    Views
    452

    Are you using the Trane cable? did you try M with...

    Are you using the Trane cable? did you try M with your caps lock on?
  39. Replies
    6
    Views
    592

    Thank you. That is exactly what I was looking for.

    Thank you. That is exactly what I was looking for.
  40. Replies
    6
    Views
    592

    Yes, I am talking tridium versions. thank you for...

    Yes, I am talking tridium versions. thank you for the info.
  41. Replies
    6
    Views
    592

    AX Version upgrades

    I have a question about version upgrades. I have a 5.5.25 version. is the upgrade to 5.5.43 free or do I need a license? this is on a Johnson FX20.
  42. PCLEdit and BMN is for old Tracer panels there...

    PCLEdit and BMN is for old Tracer panels there is no way That I know of to back up an old Tracker panel. the only way to communicate to one of those is with HyperTerminal or any other communications...
  43. Replies
    4
    Views
    423

    Good idea. I will try that when I get back there....

    Good idea. I will try that when I get back there. I had one a while ago that was very slow. it turned out to be the dns server. But I tried that with this one and it didn't help.
  44. Replies
    4
    Views
    423

    The controller is fine ( there is only 1 FX15 ) I...

    The controller is fine ( there is only 1 FX15 ) I am talking about the IP network.
  45. Replies
    4
    Views
    423

    FX20 Problem

    I am having a problem with an FX20 that I have never seen before. I can log on when it is disconnected from the network but the minute I hook it up to the network the status light starts blinking...
  46. Replies
    5
    Views
    989

    That looks like a comm 4 vav board to me. is this...

    That looks like a comm 4 vav board to me. is this on a vav?
  47. Replies
    6
    Views
    477

    What version of hvacpro are you using?

    What version of hvacpro are you using?
  48. Replies
    8
    Views
    890

    I have the same one. it works great.

    I have the same one. it works great.
  49. Replies
    1
    Views
    292

    Yes, I am running Rover 7 and Summit 17 on win 7...

    Yes, I am running Rover 7 and Summit 17 on win 7 Pro 64 bit with no problems. I also run UPCM Edit, PCM Edit, etc.. in Virtual XP with dosbox and it all works fine.
  50. Replies
    4
    Views
    611

    That is what I did. I was trying to see if there...

    That is what I did. I was trying to see if there was any other way to program it before I spent the money. :) Thanks for the reply.
Results 1 to 50 of 447
Page 1 of 9 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event